Survey | When (UTC) | Latitude | Longitude | Instrument | Identifier | Action | Log | Subject / Comments |
---|---|---|---|---|---|---|---|---|
IN2015_C01 | 2015-10-26 18:58 [view ] | -40.0179 | 141.9961 | Air Chemistry [view] | restarted | in2015_c01 | aerodyne software crash Aerodyne out since lost settings 24/6. | |
IN2015_E03 | 2015-04-17 03:50 [view ] | -43.0993 | 147.4628 | Air Chemistry [view] | incident | in2015_e03 | Aerodyne Aerodyne sample pressure 5Torr out of range, regulator valve adjusted to show appropriate level of 40Torr. | |
IN2015_E04 | 2015-04-28 06:21 [view ] | -42.9285 | 147.3808 | Air Chemistry [view] | Stop | in2015_e04 | Sampling pump off; air inlet controller off | |
IN2015_E05 | 2015-05-04 20:40 [view ] | -42.9004 | 147.3628 | Air Chemistry [view] | Steve Thomas | Stop | in2015_e05 | Air sampling pump stopped - end of voyage |
IN2015_E05 | 2015-05-04 20:48 [view ] | -42.8922 | 147.3530 | Air Chemistry [view] | Steve Thomas | Stop | in2015_e05 | Air sampling inlet controller into PARK and turned off - end of voyage |
IN2015_V01 | 2015-03-29 07:50 [view ] | -45.0008 | 146.7195 | Air Chemistry [view] | Spectroscopy | IN2015_v01 | Picarro & Aerodyne Calibration end Calibration performed on both instruments four cycles each. Resumed normal sampling schedule. | |
IN2016_T01 | 2016-07-05 03:08 [view ] | -20.3950 | 161.6033 | Air Chemistry [view] | in2016_t01 | MWR tipping point calibration - successful | ||
IN2016_V01 | 2016-01-08 10:00 [view ] | -32.1670 | 115.2587 | Air Chemistry [view] | transit | Air Sampling | in2016_v01 | Trace metal clean aerosol filter sampling start |
IN2016_V03 | 2016-06-02 03:49 [view ] | -35.7174 | -170.0036 | Air Chemistry [view] | Recovered | in2016_v03 | O2 Analyser O2 system was not sampling correctly since the last voyage. Problem was blocked/frozen-moisture in 1/8'' swagelok sample line that runs through a chiller (-80C). | |
IN2016_V05 | 2016-09-30 08:18 [view ] | -20.9938 | 150.1986 | Air Chemistry [view] | Start | in2016_v05 | Stabilised Platform started | |
IN2016_V05 | 2016-09-30 17:54 [view ] | -20.9916 | 150.2016 | Air Chemistry [view] | restarted | in2016_v05 | Stabilised platform restarted for software update | |
IN2016_V05 | 2016-09-30 18:45 [view ] | -20.9935 | 150.2020 | Air Chemistry [view] | restarted | in2016_v05 | Stabilised platform restarted restarted for software update | |
IN2016_V05 | 2016-10-02 23:10 [view ] | -20.8274 | 153.0670 | Air Chemistry [view] | Stop | in2016_v05 | Stabilised Platform stopped Stabilised Platform stopped for PC maintenance | |
IN2016_V05 | 2016-10-03 05:10 [view ] | -20.8222 | 153.0895 | Air Chemistry [view] | Start | in2016_v05 | Stabilised Platform started | |
IN2016_V05 | 2016-10-03 07:30 [view ] | -20.8177 | 153.1042 | Air Chemistry [view] | Air Sampling | in2016_v05 | bridge reported ship passing | |
IN2016_V05 | 2016-10-06 02:51 [view ] | -18.1668 | 147.2029 | Air Chemistry [view] | test | in2016_v05 | Stabilised Platformtesting during past half hour | |
IN2016_V05 | 2016-10-07 04:50 [view ] | -18.5791 | 146.9731 | Air Chemistry [view] | restarted | in2016_v05 | Stabilised Platform modified code modified to set constant -3 degree offset in roll | |
IN2016_V05 | 2016-10-10 01:27 [view ] | -18.5818 | 146.9780 | Air Chemistry [view] | outage | in2016_v05 | Stabilised Platform testing during 00:00 to 01:30 | |
IN2017_T01 | 2017-10-05 04:38 [view ] | -11.5294 | 128.4486 | Air Chemistry [view] | maintenance | in2017_t01 | Manifold T&RH fixed The regex capturing the HMT317 data was not set up to handle humidities above 99.9%. I have corrected this. | |
IN2017_T02 | 2017-11-25 03:55 [view ] | -43.4540 | 145.7222 | Air Chemistry [view] | calibration | in2017_t02 | Aerodyne and Picarro put in calibration mode | |
IN2017_V04 | 2017-08-31 07:11 [view ] | -26.9678 | 153.2267 | Air Chemistry [view] | Start | in2017_v04 | Air Chemistry Instruments Running Aerodyne not working | |
IN2018_V05 | 2018-10-16 12:14 [view ] | -44.1525 | 147.8240 | Air Chemistry [view] | restarted | in2018_v05 | restarted picarro due to high number of errors reporting 'bad sensor data format' - seems to be OK now | |
IN2018_V05 | 2018-10-16 12:14 [view ] | -44.1525 | 147.8240 | Air Chemistry [view] | restarted | Hydrochem_in2018_v02 | restarted picarro due to high number of errors reporting 'bad sensor data format' - seems to be OK now | |
IN2019_V06 | 2019-11-19 00:13 [view ] | -12.1205 | 130.6787 | Air Chem Lab [view] | Change | in2019_v06_Atmospherics | Lab Air Con Temp increased to 27 Outside dew point exceeds 25C. RH in Air Chem manifold is 95% and increasing. Lab temp increased to try to increase manifold temp and prevent droplets from forming | |
IN2020_V01 | 2020-01-13 01:04 [view ] | -41.1963 | 104.4358 | Air Chem Lab [view] | Change | in2020_v01_Atmospherics | Air chem lab temperature set to 22 degrees Ian requested the lab temperature to be set to 22 degrees once the dew point outside is consistently below 20 degrees | |
IN2021_T01 | 2021-06-13 16:25 [view ] | -19.2720 | 150.3110 | Air Chem Lab [view] | Change | Atmospherics | Lab temp setpoint increased to 25C Lab temp setpoint was 21C, fan at speed 2 (of 3). Manifold was at max humidity. increased setpoint to 25C, reduced fan speed to 1. Will monitor the manifold temperature |