Survey When (UTC) LatitudeLongitude InstrumentIdentifierActionLogSubject / Comments
IN2015_C01 2015-10-26 18:58 [view ] -40.0179 141.9961 Air Chemistry [view] restarted in2015_c01 aerodyne software crash Aerodyne out since lost settings 24/6.
IN2015_E03 2015-04-17 03:50 [view ] -43.0993 147.4628 Air Chemistry [view] incident in2015_e03 Aerodyne Aerodyne sample pressure 5Torr out of range, regulator valve adjusted to show appropriate level of 40Torr.
IN2015_E04 2015-04-28 06:21 [view ] -42.9285 147.3808 Air Chemistry [view] Stop in2015_e04 Sampling pump off; air inlet controller off
IN2015_E05 2015-05-04 20:40 [view ] -42.9004 147.3628 Air Chemistry [view] Steve Thomas Stop in2015_e05 Air sampling pump stopped - end of voyage
IN2015_E05 2015-05-04 20:48 [view ] -42.8922 147.3530 Air Chemistry [view] Steve Thomas Stop in2015_e05 Air sampling inlet controller into PARK and turned off - end of voyage
IN2015_V01 2015-03-29 07:50 [view ] -45.0008 146.7195 Air Chemistry [view] Spectroscopy IN2015_v01 Picarro & Aerodyne Calibration end Calibration performed on both instruments four cycles each. Resumed normal sampling schedule.
IN2016_T01 2016-07-05 03:08 [view ] -20.3950 161.6033 Air Chemistry [view] in2016_t01 MWR tipping point calibration - successful
IN2016_V01 2016-01-08 10:00 [view ] -32.1670 115.2587 Air Chemistry [view] transit Air Sampling in2016_v01 Trace metal clean aerosol filter sampling start
IN2016_V03 2016-06-02 03:49 [view ] -35.7174 -170.0036 Air Chemistry [view] Recovered in2016_v03 O2 Analyser O2 system was not sampling correctly since the last voyage. Problem was blocked/frozen-moisture in 1/8'' swagelok sample line that runs through a chiller (-80C).
IN2016_V05 2016-09-30 08:18 [view ] -20.9938 150.1986 Air Chemistry [view] Start in2016_v05 Stabilised Platform started
IN2016_V05 2016-09-30 17:54 [view ] -20.9916 150.2016 Air Chemistry [view] restarted in2016_v05 Stabilised platform restarted for software update
IN2016_V05 2016-09-30 18:45 [view ] -20.9935 150.2020 Air Chemistry [view] restarted in2016_v05 Stabilised platform restarted restarted for software update
IN2016_V05 2016-10-02 23:10 [view ] -20.8274 153.0670 Air Chemistry [view] Stop in2016_v05 Stabilised Platform stopped Stabilised Platform stopped for PC maintenance
IN2016_V05 2016-10-03 05:10 [view ] -20.8222 153.0895 Air Chemistry [view] Start in2016_v05 Stabilised Platform started
IN2016_V05 2016-10-03 07:30 [view ] -20.8177 153.1042 Air Chemistry [view] Air Sampling in2016_v05 bridge reported ship passing
IN2016_V05 2016-10-06 02:51 [view ] -18.1668 147.2029 Air Chemistry [view] test in2016_v05 Stabilised Platformtesting during past half hour
IN2016_V05 2016-10-07 04:50 [view ] -18.5791 146.9731 Air Chemistry [view] restarted in2016_v05 Stabilised Platform modified code modified to set constant -3 degree offset in roll
IN2016_V05 2016-10-10 01:27 [view ] -18.5818 146.9780 Air Chemistry [view] outage in2016_v05 Stabilised Platform testing during 00:00 to 01:30
IN2017_T01 2017-10-05 04:38 [view ] -11.5294 128.4486 Air Chemistry [view] maintenance in2017_t01 Manifold T&RH fixed The regex capturing the HMT317 data was not set up to handle humidities above 99.9%. I have corrected this.
IN2017_T02 2017-11-25 03:55 [view ] -43.4540 145.7222 Air Chemistry [view] calibration in2017_t02 Aerodyne and Picarro put in calibration mode
IN2017_V04 2017-08-31 07:11 [view ] -26.9678 153.2267 Air Chemistry [view] Start in2017_v04 Air Chemistry Instruments Running Aerodyne not working
IN2018_V05 2018-10-16 12:14 [view ] -44.1525 147.8240 Air Chemistry [view] restarted in2018_v05 restarted picarro due to high number of errors reporting 'bad sensor data format' - seems to be OK now
IN2018_V05 2018-10-16 12:14 [view ] -44.1525 147.8240 Air Chemistry [view] restarted Hydrochem_in2018_v02 restarted picarro due to high number of errors reporting 'bad sensor data format' - seems to be OK now
IN2019_V06 2019-11-19 00:13 [view ] -12.1205 130.6787 Air Chem Lab [view] Change in2019_v06_Atmospherics Lab Air Con Temp increased to 27 Outside dew point exceeds 25C. RH in Air Chem manifold is 95% and increasing. Lab temp increased to try to increase manifold temp and prevent droplets from forming
IN2020_V01 2020-01-13 01:04 [view ] -41.1963 104.4358 Air Chem Lab [view] Change in2020_v01_Atmospherics Air chem lab temperature set to 22 degrees Ian requested the lab temperature to be set to 22 degrees once the dew point outside is consistently below 20 degrees
IN2021_T01 2021-06-13 16:25 [view ] -19.2720 150.3110 Air Chem Lab [view] Change Atmospherics Lab temp setpoint increased to 25C Lab temp setpoint was 21C, fan at speed 2 (of 3). Manifold was at max humidity. increased setpoint to 25C, reduced fan speed to 1. Will monitor the manifold temperature