Data Trawler - Survey Details

Please login if you have access to particular applications.
Username:
Password:

Voyage details and related metadata, reports, events and data.

IN2019_V06    - is a Marine National Facility voyage

Title: Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability

Voyage details on MNF site: https://mnf.csiro.au/en/Voyages/IN2019_V06

Period: 2019-10-19 10:30 to 2019-12-16 22:05 UTC

Duration: 58.48 days

From: Darwin To: Darwin

Region: Timor Sea, East Indian Ocean

Ship: Investigator (RV) [details]

Description: Accurate predictions of Australia’s regional weather and climate require accurate representations of atmospheric and oceanic processes in our prediction models over the entire globe, and not just over Australia. However, some global locations are more important than others, and one is the region known as the ‘Maritime Continent’, comprising the islands and seas of Indonesia, Malaysia, New Guinea, and surrounds. This voyage will form part of a larger international effort to tackle the problems of the Maritime Continent in our models by making detailed observations of the daily cycles of convective storms and the mixing of heat in the atmosphere and ocean.

Leader: Alain Protat (BOM)

Projects:

  • Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability [details] Primary

  • RBR Argo CTD testing [details] Piggy-back


Voyage extents: 14° 40.8' S to 10° 47.8' S    120° 33.0' E to 133° 26.8' E Get voyage track shapefile Get CSV


Marlin Metadata:-

  • RV Investigator IN2019_V06 BASTA radar and Radiosonde data [details]

  • RV Investigator ISAR/SST Sea Surface Temperature Data Overview (2014 onwards) [details]

  • RV Investigator Radon Data - Selected Voyages (2014 onwards) [details]

  • RV Investigator Sea Carbon Dioxide (CO2) Data - Selected Voyages (2014 onwards) [details]

  • RV Investigator Voyage IN2019_V06 ADCP Data [details]

  • RV Investigator Voyage IN2019_V06 CTD Data [details]

  • RV Investigator Voyage IN2019_V06 EK60 Echosounder [details]

  • RV Investigator Voyage IN2019_V06 EM122 Multibeam Echosounder Data [details]

  • RV Investigator Voyage IN2019_V06 EM710 Multibeam Echosounder Data [details]

  • RV Investigator Voyage IN2019_V06 End of Voyage (EOV) Archive [details]

  • RV Investigator Voyage IN2019_V06 Gravity Data [details]

  • RV Investigator Voyage IN2019_V06 Hydrology Data [details]

  • RV Investigator Voyage IN2019_V06 SBP120 Sub-bottom Profiler Data [details]

  • RV Investigator Voyage IN2019_V06 Triaxus (undulating CTD) Data [details]

  • RV Investigator Voyage IN2019_V06 Underway UWY Data [details]

  • RV Investigator Voyage IN2019_V06 XBT Data [details]

  • Cruise Summary Report at SeaDataNet:-

  • View Cruise Summary Report at https://csr.seadatanet.org
  • Participants - on ship:-

    NameLegRoleOrganisation Project
    Alain Protat 2 Chief Scientist Bureau of Meteorology Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Damien Callahan 1 Biology Deakin University Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Don McKenzie 2 Voyage Manager CSIRO Oceans & Atmosphere - Hobart Voyage Management on RV Investigator
    Hugh Barker 1 Voyage Manager CSIRO Oceans & Atmosphere - Hobart Voyage Management on RV Investigator
    Matthew Wheeler 1 Deputy Chief Scientist / PI Bureau of Meteorology Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Robin Robertson 1 2 Ocean Xiamen University, Malaysia Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Ruhi Humphries 1 PI - Aerosols CSIRO Oceans & Atmosphere - Aspendale Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Susan Wijffels 1 Chief Scientist CSIRO Oceans & Atmosphere - Hobart Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Zoran Ristovski 1 PI - Aerosols Queensland University of Technology Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability

    Participants - shore based:-

    NameRoleOrganisation Project
    Alex Johnson Principal Investigator University of Melbourne Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Charmaine Franklin Principal Investigator Bureau of Meteorology Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Christian Jakob Principal Investigator Monash University Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Eric Schulz Principal Investigator Bureau of Meteorology Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Fadli Syamsudin Principal Investigator BPPT, Indonesia Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Jason Monty Principal Investigator University of Melbourne Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Mei Zheng Principal Investigator Peking University Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Po-Hsiung Lin Principal Investigator National Taiwan University, Taiwan Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Robyn Schofield Principal Investigator University of Melbourne Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Todd Lane Principal Investigator University of Melbourne Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability
    Zhiyu Liu Principal Investigator Xiamen University Tropical observations of atmospheric convection, biogenic emissions, ocean mixing, and processes generating intraseasonal SST variability

    This list includes those that may have only been on part of the voyage. See voyage reports on 'Reports and Maps' tab for details.

    Marine National Facility Reports - plans, summaries and data processing

    Publications, reports and datasets from this voyage.

    Dataset

    • Cowley, Rebecca; Dever, Mathieu (2022): Investigator in2019_v06 WireWalker data from RBR Concerto CTD. v2. CSIRO. Data Collection. https://doi.org/10.25919/7hnt-bj11     10.25919/7hnt-bj11

    • Protat, Alain; McRobert, Ian; Marine National Facility; CSIRO (2020): RV Investigator IN2019_V06 BASTA radar and Radiosonde data. v3. CSIRO. Data Collection.     10.25919/5ef5a70ae2be9

    Journal Article

    • Protat, Alain & McRobert, Ian. (2020). Three-dimensional wind profiles using a stabilized shipborne cloud radar in wind profiler mode. Atmospheric Measurement Techniques. 13. 3609-3620. 10.5194/amt-13-3609-2020.     10.5194/amt-13-3609-2020

    • Protat, Alain,Louf, Valentin,Soderholm, Joshua,Brook, Jordan,Ponsonby, William (2022) Three-way calibration checks using ground-based, ship-based, and spaceborne radars. Atmospheric Measurement Techniques 15 pp915-926.     10.5194/amt-15-915-2022

    • Robertson, R.,Zhao, C.,Wang, W.,Xu, Z.,Liu, Z. (2023) A case study off the Tiwi Islands and the Coburg Peninsula: Baroclinic on one side and barotropic on the other. Progress in Oceanography 216 pp103057-.     10.1016/j.pocean.2023.103057

    • Short, Ewan,Lane, Todd P.,Bishop, Craig H.,Wheeler, Matthew C. (2023) Diurnally Forced Tropical Gravity Waves under Varying Stability. Journal of the Atmospheric Sciences 80 pp2557-2579.     10.1175/JAS-D-23-0074.1

    • Wu, Changda,Trounce, Haydn,Dunne, Erin,Griffith, David W.T.,Chambers, Scott D.,Williams, Alastair G.,Humphries, Ruhi S.,Cravigan, Luke T.,Miljevic, Branka,Zhang, Chunlin,Wang, Hao,Wang, Boguang,Ristovski, Zoran (2023) Atmospheric concentrations and sources of black carbon over tropical Australian waters. Science of The Total Environment 856 pp159143-.     10.1016/j.scitotenv.2022.159143

    • Zhang, Haifeng,Beggs, Helen,Griffin, Christopher,Govekar, Pallavi Devidas (2023) Validation of Himawari-8 Sea Surface Temperature Retrievals Using Infrared SST Autonomous Radiometer Measurements. Remote Sensing 15 pp2841-.     10.3390/rs15112841

    Search for publications, reports and datasets from this and other voyages

    Data publishing

    This is a list of online datasets hosted by CSIRO. Other processed datasets hosted by collaborating organisations may be found on the 'Metadata' or "Reports, Publications and Maps' tab.
    Use the Get data link on the right to extract data using the NCMI Data Trawler.

    Data StreamData SummaryGet data
    ADCP Data
    Time (UTC): 2019-10-19 22:10 to 2019-12-17 08:12
    Latitude: -14.68 to -10.80
    Longitude: 120.55 to 133.45
    Ensembles: 24,967
    Get Data from Trawler

    Download ADCP Data (NetCDF, 5 minute)

    Download overview plots of collected data

    Download overview plots of collected data

    Download overview plots of collected data

    CTD profile
    Time (UTC): 2019-10-21 07:10 to 2019-12-14 02:12
    Latitude: -14.67 to -11.20
    Longitude: 120.55 to 133.45
    Quantity: 423 Casts
    Max Pressure: 2002 db
    Get Data from Trawler

    Download the Leg-1 CTD Data (NetCDF format)

    Download the Leg-1 CTD Data (CSV format)

    Download the Leg-1 CTD Data (Matlab format)

    Download the Leg-2 CTD Data (NetCDF format)

    Download the Leg-2 CTD Data (CSV format)

    Download the Leg-2 CTD Data (MATLAB format)

    Hydrology
    Time (UTC): 2019-10-21 07:10 to 2019-12-14 02:12
    Latitude: -14.67 to -11.21
    Longitude: 120.55 to 133.43
    Quantity: 47 Casts
    Max Pressure: 2002 db
    Get Data from Trawler

    Download the Hydrology Data (CSV format): in2019_v06_Hydro_Deploymnets_CSV.zip

    Download the Hydrology Data (NetCDF format): in2019_v06_Hydro_Deployments_NetCDF.zip

    Download the Hydrology TSG Samples (CSV format): in2019_v06_Hydro_TSG_CSV.zip

    Download the Hydrology Elogs (CSV format): in2019_v06_Hydro_TSG_Samples_eLog.zip

    in2019_v06 Leg2 TSG Calibration Bottle Results

    Multibeam echosounder
    Time (UTC): 2019-10-14 00:10 to 2019-12-16 21:12
    Latitude: -14.67 to -10.80
    Longitude: 120.55 to 133.44
    Datafiles: 802
    Total size: 174.21 Gb
    Get Data from Trawler

    Geophysical Survey and Mapping data acquisition and processing report

    pCO2
    Time (UTC): 2019-10-19 11:47 to 2019-12-11 09:37
    Latitude: -14.68 to -10.80
    Longitude: 120.55 to 133.45
    Observations: 44182
    External link - download datafile at IMOS
    Data fields and units document (.pdf)

    Radon measurements
    Time (UTC): 2019-10-18 00:00 to 2019-12-19 23:00
    Latitude: -14.67 to -10.80
    Longitude: 120.55 to 133.45
    Measurements:1500
    Get Data from Trawler

    Download RV Investigator Radon dataset (XLSX)

    Sub-bottom profiler
    Time (UTC): 2019-10-20 12:22 to 2019-11-10 10:47
    Latitude: -14.67 to 0.87
    Longitude: 120.55 to 130.61
    Datafiles: 780
    Total size: 13.25 Gb
    Get Data from Trawler

    Geophysical Survey and Mapping data acquisition and processing report

    Singlebeam echosounder
    Time (UTC): 2019-10-19 12:04 to 2019-10-19 19:01
    Latitude: -12.51 to -12.29
    Longitude: 129.81 to 130.51
    Datafiles: 87
    Total size: 8.23 Gb
    Get Data from Trawler

    Geophysical Survey and Mapping acquisition report

    Sea Surface Temperature
    Time (UTC): 2019-10-20 02:40 to 2019-12-16 22:00
    Latitude: -14.68 to -10.82
    Longitude: 120.55 to 133.45
    Measurements:27545
    Get Data from Trawler

    Download IN2019_V06 compressed dataset (11 Mb)

    Towed CTD
    Time (UTC): 2019-10-24 01:10 to 2019-11-04 21:11
    Latitude: -14.36 to -14.20
    Longitude: 121.25 to 121.46
    Tows: 8
    Duration: 81.54 hours
    Data points: 311,405
    Maximum Depth: 106.00 m
    Get Data from Trawler

    Download the along-track Triaxus Data (NetCDF format)

    Download plots associated with the Processing Report

    Download vertical-cast Triaxus Data (NetCDF format)

    Underway
    Time (UTC): 2019-10-19 10:10 to 2019-11-10 09:11
    Latitude: -12.47
    Longitude: 130.85
    Track length: 7497.592 km
    Locations: 992,344
    Measurements: 71,448,768
    Get Data from Trawler

    Download the 5 second Data (netcdf) - Leg1

    Download the 5 second Data (netcdf) - Leg2

    Download the 5 second Data (csv) - Leg1

    Download the 5 second Data (csv) - Leg2

    Download the 10 second Data (csv) - Leg1

    Download the 10 second Data (csv) - Leg2

    Download the 1 minute Data (csv) - Leg1

    Download the 1 minute Data (csv) - Leg2

    Download the 5 minute Data (csv) - Leg1

    Download the 5 minute Data (csv) - Leg2

    Download the Salinity Bottle Calibration Data (csv) - Leg1

    Download the Salinity Bottle Calibration Data (csv) - Leg2

    XBT Profile
    Time (UTC): 2019-10-23 08:10 to 2019-12-13 03:12
    Latitude: -14.57 to -10.83
    Longitude: 121.08 to 132.13
    Quantity: 33 Casts
    Max Pressure: 1100.3 db
    Get Data from Trawler

    Geophysical Survey and Mapping data acquisition and processing report

    Caveat: this event log was authored on the voyage using either a standalone logging system called ELOG or more recently an inhouse event logging tool called Everlog. For this reason, some positions are unknown and may be resolved using the logged time and the underway dataset for the voyage.

    Search for events from this voyage and others

    Events ordered by start time:- Click on column header to sort. Use link on 'When' to see full details. Use the CSV button at the bottom to export data.

    When (UTC) LatitudeLongitude InstrumentIdentifierActionLogSubject / Comments
    2019-10-19 11:01 [view ] -12.4717 130.8197 EM710 [view] Start GSM_in2019_v06 Passage sounding Started Waiting for AML (Sound Velocity Probe) hull mounted to start to apply to display.
    2019-10-19 11:41 [view ] -12.3838 130.7460 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_001.asvp SVP created in svp builder using climatology and TSG data. Applied.
    2019-10-19 12:15 [view ] -12.3210 130.6698 EK60 [view] Start GSM_in2019_v06 started logging EK60 sounder data
    2019-10-19 12:23 [view ] -12.3143 130.6500 SBP [view] Start GSM_in2019_v06 start logging raw and segy
    2019-10-19 12:41 [view ] -12.2967 130.5977 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_002.asvp
    2019-10-19 16:33 [view ] -12.3913 129.8245 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_004.asvp SVP created using hull mounted SV and climatology. Applied
    2019-10-19 22:51 [view ] -12.6062 129.6748 EM710 [view] Observation GSM_in2019_v06 ADCP interference with EM710 ADCPs online. Notable spikes intermittent through EM710 multibeam data.
    2019-10-19 23:00 [view ] -12.6077 129.6458 EM710 [view] Filter GSM_in2019_v06 Spike Filter Strength change Filtering and gains setting changed from MEDIUM to STRONG. Spikes observed but less often. ADCP interference.
    2019-10-19 23:17 [view ] -12.6100 129.5905 EM710 [view] Observation GSM_in2019_v06 TX Power Level change A test to see if a lesser TX power setting would improve the data. -20, -10, Returned to .max Heavy spikes observed.
    2019-10-20 03:45 [view ] -12.6120 128.7303 EM710 [view] Ping rate GSM_in2019_v06 Change Ping Rate Ping rate changed to Shallow (100m-200m depth)
    2019-10-20 05:12 [view ] -12.6317 128.4428 Other [view] Other GSM_in2019_v06 qinsy stopped qinsy but when restarted the grid wouldnt display (test_again.grd 2.9GB)
    2019-10-20 06:03 [view ] -12.6513 128.2787 Outage in2019_v06_Atmospherics Opened tap on manifold to connect the AIRBOX Ozone and NOX in the aerosol lab
    2019-10-20 08:28 [view ] -12.7258 127.8348 EM710 [view] GSM_in2019_v06 try frequency 50 Hz ; now interference on port side! will try other frequencies
    2019-10-20 08:35 [view ] -12.7295 127.8137 EM710 [view] note GSM_in2019_v06 back to 70-100kHz
    2019-10-20 09:18 [view ] -12.8762 126.9403 Hydrochem Lab : UW_Sea_Water_Samples_in2019_v06
    2019-10-20 10:19 [view ] -12.8768 126.9358 Hydrochem Lab : UW_Sea_Water_Samples_in2019_v06
    2019-10-20 10:52 [view ] -12.7983 127.4037 Hydrochem Lab : UW_Sea_Water_Samples_in2019_v06
    2019-10-20 11:28 [view ] -12.8170 127.2920 Deployed WeatherBalloon_in2019_v06 Balloon radiosonde
    2019-10-20 11:41 [view ] -12.8238 127.2515 EM710 [view] warning GSM_in2019_v06 PPS red off
    2019-10-20 11:44 [view ] -12.8253 127.2430 EM710 [view] warning GSM_in2019_v06 stopped pinging pps on then when logging pps off
    2019-10-20 11:51 [view ] -12.8290 127.2207 EM710 [view] Other GSM_in2019_v06 power cycled transducer - PPS on now
    2019-10-20 12:56 [view ] -12.8638 127.0135 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_006.asvp
    2019-10-20 13:32 [view ] -12.8838 126.8947 Gravity Meter [view] Other GSM_in2019_v06 ambient temperature 30.8 techsas alarm
    2019-10-20 13:39 [view ] -12.8877 126.8713 Gravity Meter [view] note GSM_in2019_v06 operating temperature range is 5 to 40
    2019-10-20 13:55 [view ] -12.8963 126.8200 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_007.asvp
    2019-10-20 15:07 [view ] -12.9367 126.5793 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_008.asvp
    2019-10-20 16:01 [view ] -12.9675 126.3957 EM710 [view] Ping rate GSM_in2019_v06 Change Ping Rate Ping rate reverted back to Very Shallow (0-100m). Current depth 80m
    2019-10-20 16:17 [view ] -12.9767 126.3420 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_009.asvp SVP conducted using Hull mounted sensor data SST and Sanlinity. Climatology used to generate the profile.
    2019-10-20 19:30 [view ] -13.0705 125.7318 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_010.asvp SVP builder utilising Hull mounted Salininty and SST. Climatology used to generate profile.
    2019-10-20 19:34 [view ] -13.0720 125.7200 EM710 [view] note GSM_in2019_v06 Interference observed in the Nadir Spikes in the nadir have been consistant in the waterfall display.
    2019-10-20 23:15 [view ] -13.1597 125.0177 Deployed WeatherBalloon_in2019_v06
    2019-10-20 23:52 [view ] -13.1748 124.8963 EM710 [view] note GSM_in2019_v06 Sector Coverage Sector coverage Narrowed to 60m both P/S due to heavy noise in outer beams. Improvement noticed.
    2019-10-21 00:13 [view ] -13.1840 124.8225 EM710 [view] note GSM_in2019_v06 Change filtering Spike filtering is reverted to NORMAL, Penetration filter has been increased to STRONG, Force depth to 100m applied. Improvements in noise in the outerbeams. ADCP still affecting.
    2019-10-21 00:20 [view ] -13.1865 124.8023 EM710 [view] Observation GSM_in2019_v06 Sector Coverage Sector coverage extended back to 70m P/S will monitor outerbeams. Some noise observed.
    2019-10-21 00:36 [view ] -13.1933 124.7477 EM710 [view] Observation GSM_in2019_v06 Sector Coverage Sector coverage P/S reverted back to 60 degrees. Heavy noise observed in outer beams.
    2019-10-21 00:44 [view ] -13.1967 124.7215 EM710 [view] Ping rate GSM_in2019_v06 Change Ping Rate Ping rate set to MEDIUM from SHALLOW. Seemed to improve the noise. Penetration filter STRONG.
    2019-10-21 02:50 [view ] -13.2467 124.3205 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_011.asvp SVP Cast conducted using Hull SST and Salinity. Climatology was used for the profile. Applied
    2019-10-21 03:36 [view ] -13.2645 124.1768 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_012.asvp SVP created using Hull SST and Salinity. Climatology used to create the profile. Applied.
    2019-10-21 04:57 [view ] -13.2943 123.9373 EM710 [view] note GSM_in2019_v06 K-Sync Change Range Range changed to <500.
    2019-10-21 05:03 [view ] -13.2963 123.9213 EM122 [view] Start GSM_in2019_v06 EM122 Pinging EM122 pinging. SVP in2019_v06_sst_012 applied. Ping mode SHALLOW. Penetration filter strentgh MEDIUM
    2019-10-21 05:09 [view ] -13.2985 123.9035 EM122 [view] Start GSM_in2019_v06 EM122 Start Logging EM122 Started Logging.
    2019-10-21 06:13 [view ] -13.3227 123.7122 VH-TDMA [view] Restart AIRBOX_in2019_v06 restarted frozen computer
    2019-10-21 06:20 [view ] -13.3235 123.7080 EM122 [view] note GSM_in2019_v06 Stopped in the water CTD Cast Stopped in the water CTD Cast.
    2019-10-21 06:48 [view ] -13.3242 123.7068 Ozone Monitor [view] Maintenance in2019_v06_Atmospherics pumps off, sample line tap off to drain condensation
    2019-10-21 07:28 [view ] -13.3242 123.7070 Underway Merinda McMahon Hydrochem Lab : TSG01 Sample TSG_Samples_in2019_v06
    2019-10-21 07:31 [view ] -13.3240 123.7073 Underway Merinda McMahon Hydrochem Lab : TSG02 Sample TSG_Samples_in2019_v06
    2019-10-21 07:33 [view ] -13.3240 123.7075 Underway Merinda McMahon Hydrochem Lab : TSG03 Sample TSG_Samples_in2019_v06
    2019-10-21 07:47 [view ] -13.3663 123.4130 Microbiology_in2019_v06
    2019-10-21 07:47 [view ] -13.3663 123.4130 Microbiology_in2019_v06
    2019-10-21 07:47 [view ] -13.3663 123.4130 Microbiology_in2019_v06
    2019-10-21 09:00 [view ] -14.3067 121.1140 O3 NOX Change AIRBOX_in2019_v06 ntp sync to ship server rough estimate of the time ntp was updated on acquisition machine
    2019-10-21 09:24 [view ] -13.3372 123.6530 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_001.asvp
    2019-10-21 09:50 [view ] -13.3445 123.5727 EK60 [view] Depth Mode GSM_in2019_v06 set to 1500
    2019-10-21 11:14 [view ] -13.3830 123.2987 Deployed WeatherBalloon_in2019_v06
    2019-10-21 15:02 [view ] -13.4872 122.5878 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_013.asvp
    2019-10-21 15:37 [view ] -13.4992 122.5003 Underway Merinda McMahon Hydrochem Lab : TSG04 Sample TSG_Samples_in2019_v06
    2019-10-21 15:40 [view ] -13.4990 122.5007 Underway Merinda McMahon Hydrochem Lab : tsg05 Sample TSG_Samples_in2019_v06
    2019-10-21 15:42 [view ] -13.4990 122.5008 Underway Merinda McMahon Hydrochem Lab : tsg06 Sample TSG_Samples_in2019_v06
    2019-10-21 15:58 [view ] -13.4980 122.5027 Microbiology_in2019_v06
    2019-10-21 15:58 [view ] -13.4980 122.5027 Microbiology_in2019_v06
    2019-10-21 15:58 [view ] -13.4980 122.5027 Microbiology_in2019_v06
    2019-10-21 18:21 [view ] -13.2700 122.2212 K-Sync [view] note GSM_in2019_v06 K-Sync Change Range K-Sync range changed to <1000m.
    2019-10-21 18:28 [view ] -13.2560 122.2043 EM122 [view] Ping rate GSM_in2019_v06 Ping Mode Change Ping mode changed from shallow to MEDIUM
    2019-10-21 18:32 [view ] -13.2480 122.1945 EM122 [view] note GSM_in2019_v06 Ping Mode Change Depth 710 attempt to change Ping mode to MEDIUM caused noise so reverted back to SHALLOW and increased penetration filter strength to STRONG
    2019-10-21 19:23 [view ] -13.1703 122.1007 Underway Christine Rees Hydrochem Lab : TSG07 Sample TSG_Samples_in2019_v06
    2019-10-21 19:24 [view ] -13.1703 122.1007 Microbiology_in2019_v06
    2019-10-21 19:24 [view ] -13.1703 122.1007 Microbiology_in2019_v06
    2019-10-21 19:24 [view ] -13.1703 122.1007 Microbiology_in2019_v06
    2019-10-21 19:26 [view ] -13.1703 122.1007 Underway Christine Rees Hydrochem Lab : TSG08 Sample TSG_Samples_in2019_v06
    2019-10-21 19:27 [view ] -13.1703 122.1007 Underway Christine Rees Hydrochem Lab : TSG09 Sample TSG_Samples_in2019_v06
    2019-10-21 21:55 [view ] -13.3857 121.9072 EM122 [view] Observation GSM_in2019_v06 Sector Coverage Angle Change Swath angle changed form 70 degrees to 60 degrees noise in the outer beams. Depth forced to 900m
    2019-10-21 22:07 [view ] -13.4140 121.8817 K-Sync [view] note GSM_in2019_v06 User config Profiles depth range change Change in depth range to <2000m
    2019-10-21 22:44 [view ] -13.5023 121.8028 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_014.asvp SVP generated from hull SST and Salinity. Climatology used to generate profile. Applied.
    2019-10-21 22:48 [view ] -13.5135 121.7927 EM122 [view] note GSM_in2019_v06 Depth settings Max depth set to 2000 from1500 small deeper hole missed. Ping mode set to MEDIUM form SHALLOW to see if there is any improvement.
    2019-10-21 23:15 [view ] -13.5790 121.7342 Deployed WeatherBalloon_in2019_v06
    2019-10-22 01:01 [view ] -13.8357 121.5042 K-Sync [view] note GSM_in2019_v06 User config Profiles depth range change Changed from <2000m to <5000m
    2019-10-22 01:52 [view ] -13.9562 121.3962 Nephelometer [view] in2019_v06_Atmospherics Exhaust detection min wind threshold changed from 10 to 3 kt This will affect the exhaust zeroing.
    2019-10-22 05:26 [view ] -14.2842 121.1117 SBP [view] Start GSM_in2019_v06 change to chirp and restart logging
    2019-10-22 07:14 [view ] -14.3067 121.1140 Picarro Spectrometer [view] Outage in2019_v06_Atmospherics software restarted no water vapour showing on the gui graph
    2019-10-22 11:13 [view ] -13.9613 120.6653 Deployed WeatherBalloon_in2019_v06
    2019-10-22 11:51 [view ] -13.8922 120.5673 Microbiology_in2019_v06
    2019-10-22 11:51 [view ] -13.8922 120.5673 Microbiology_in2019_v06
    2019-10-22 11:51 [view ] -13.8922 120.5673 Microbiology_in2019_v06
    2019-10-22 11:58 [view ] -13.8858 120.5587 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_015.asvp
    2019-10-22 12:26 [view ] -13.8798 120.5503 Underway Merinda McMahon Hydrochem Lab : TSG10 Sample TSG_Samples_in2019_v06
    2019-10-22 12:29 [view ] -13.8800 120.5503 Underway Merinda McMahon Hydrochem Lab : TSG11 Sample TSG_Samples_in2019_v06
    2019-10-22 12:31 [view ] -13.8800 120.5503 EM122 [view] Observation GSM_in2019_v06 turn SBP and EK60 off - still interference in outer beams
    2019-10-22 12:32 [view ] -13.8802 120.5503 Underway Merinda McMahon Hydrochem Lab : TSG12 Sample TSG_Samples_in2019_v06
    2019-10-22 14:11 [view ] -13.8837 120.5550 SBP [view] Start GSM_in2019_v06 after ctd station
    2019-10-22 16:41 [view ] -14.1643 120.9282 EM122 [view] Ping rate GSM_in2019_v06 Change Ping Rate Ping rate changed to DEEP. Forced depth. Cleaned up noise in outer beams.
    2019-10-22 19:26 [view ] -14.4738 121.3820 EM122 [view] Ping rate GSM_in2019_v06 New ping mode Ping mode changed to MEDIUM as we get shoaler.
    2019-10-22 20:25 [view ] -14.5822 121.5410 EM122 [view] note GSM_in2019_v06 K-Sync Change Range K-Sync Range changed to <1000m. EM122 ping mode changed to SHALLOW.
    2019-10-22 20:58 [view ] -14.6440 121.6318 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_016.asvp
    2019-10-22 21:19 [view ] -14.6708 121.6717 Microbiology_in2019_v06
    2019-10-22 21:19 [view ] -14.6708 121.6717 Microbiology_in2019_v06
    2019-10-22 21:19 [view ] -14.6708 121.6717 Microbiology_in2019_v06
    2019-10-22 21:23 [view ] -14.6708 121.6723 Underway Christine Rees Hydrochem Lab : TSG13 Sample TSG_Samples_in2019_v06
    2019-10-22 21:26 [view ] -14.6708 121.6727 Underway Christine Rees Hydrochem Lab : TSG14 Sample TSG_Samples_in2019_v06 TSG
    2019-10-22 21:27 [view ] -14.6710 121.6728 Underway Christine Rees Hydrochem Lab : TSG15 Sample TSG_Samples_in2019_v06 t
    2019-10-22 21:28 [view ] -14.6710 121.6728 EM122 [view] note GSM_in2019_v06 Stopped in the water CTD Cast
    2019-10-22 22:01 [view ] -14.6722 121.6735 Aerosol Manifold [view] Change in2019_v06_Atmospherics filter sampling lines Closed/opened filter sampling valves for filter replacement
    2019-10-22 23:01 [view ] -14.5757 121.5397 EM122 [view] Ping rate GSM_in2019_v06 Ping Mode Change SHALLOW to MEDIUM
    2019-10-22 23:13 [view ] -14.5543 121.5088 Deployed WeatherBalloon_in2019_v06
    2019-10-23 00:18 [view ] -14.4375 121.3400 EM122 [view] Depth Mode GSM_in2019_v06 Ping Mode Change MEDIUM to DEEP
    2019-10-23 00:25 [view ] -14.4235 121.3198 POSMV [view] note GSM_in2019_v06 Position Error Position Error Observed for 10 minutes. Returned to GREEN
    2019-10-23 00:44 [view ] -14.3990 121.2847 EK60 [view] Stop GSM_in2019_v06 EK60 Passive Mode Requested by Cheif Scientist (Susan) while TRIAXUS is deployed.
    2019-10-23 01:16 [view ] -14.3740 121.2547 SMPS [view] AIRBOX_in2019_v06 3782 Emtied drain bottle Filled supply bottle.
    2019-10-23 03:01 [view ] -14.3708 121.2512 SMPS [view] Maintenance AIRBOX_in2019_v06 Restarting Restarting AIM
    2019-10-23 03:04 [view ] -14.3670 121.2468 MAAP [view] Change in2019_v06_Atmospherics Changed the flow rate from 500 m3/hr to 700 m3/hr, and bypass flow from 7.3 to 4.0 LPM
    2019-10-23 03:06 [view ] -14.3633 121.2428 SMPS [view] Start AIRBOX_in2019_v06 Restarting Starting a new file: 20191023.s80
    2019-10-23 03:13 [view ] -14.3510 121.2360 VH-TDMA [view] Start AIRBOX_in2019_v06 Restarting Restarting AIM. New file H20191023.s80
    2019-10-23 03:19 [view ] -14.3390 121.2358 MAAP [view] Fault in2019_v06_Atmospherics Error messages 0000 0000 0000 8000 = filter change condition already met again after a filter change has been carried out 0000 0000 0100 8000 = deviation > 5% 0000 0000 0120 8000 = Orifice pressure > 1 hPa 0000 0000 0130 8000 = Orifice pressure > 1 hPa + Suction chamber negative pressure < 10 hPa I think the deviation, orifice and suction chamber pressures are all associated with the variable flow rate. Not sure about the filter change idea.
    2019-10-23 03:23 [view ] -14.3293 121.2360 CPC3772 [view] Start AIRBOX_in2019_v06 Restarted AIM Started a new file 3772CPC_20191023.c72
    2019-10-23 03:41 [view ] -14.2903 121.2360 MAAP [view] Fault in2019_v06_Atmospherics Took MAAP off main inlet (closed manifold tap) to test flow rate as source of error Seems turning the flowrates back up to 1000 m3/hr removed most of the errors. Not sure yet about the filter change error. I& 39;ve reconnected back to the inlet, running at 16.67 LPM and restarted the machine. This seems to have cleared all the errors for now.
    2019-10-23 03:54 [view ] -14.2627 121.2362 Aerosol Pump Sector Switch Maintenance in2019_v06_Atmospherics Ian reconfiguring remotely to get it working properly again
    2019-10-23 07:20 [view ] -14.2758 121.0642 CIMS [view] Fault AIRBOX_in2019_v06 ion source voltages not working
    2019-10-23 07:21 [view ] -14.2788 121.0642 AMS [view] Fault AIRBOX_in2019_v06 chopper not working
    2019-10-23 07:28 [view ] -14.2898 121.0645 Aethelometer [view] Stop AIRBOX_in2019_v06 stop to download the data pulled out Eyeon box that was beneath aethalometer - readings became strange so shut it down. will also download the data
    2019-10-23 07:32 [view ] -14.2968 121.0647 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 disconnecte 3010CPC Disconnected the 3010 cpc and blocked the line
    2019-10-23 08:52 [view ] -14.3505 121.1723 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_002.asvp
    2019-10-23 09:56 [view ] -14.2467 121.2532 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 reconnected 3010CPC
    2019-10-23 10:17 [view ] -14.1905 121.2488 CPC3772 [view] Change AIRBOX_in2019_v06 Added drain bottle Turned water removal on
    2019-10-23 11:12 [view ] -14.1847 121.1007 Deployed WeatherBalloon_in2019_v06
    2019-10-23 14:45 [view ] -14.3060 121.2608 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_008.asvp
    2019-10-23 23:14 [view ] -14.3497 121.1863 Deployed WeatherBalloon_in2019_v06
    2019-10-24 00:48 [view ] -14.2087 121.2798 XBT [view] SVP GSM_in2019_v06 in2019_v06_xbt_009.asvp XBT cast 015 applied
    2019-10-24 03:55 [view ] -14.3497 121.1647 in2019_v06_Atmospherics Added insulation to PTRMS tubing underneath the AC in the aerosol lab where condensation was found.
    2019-10-24 04:00 [view ] -14.3497 121.1758 Aethelometer [view] Change AIRBOX_in2019_v06 Hi Reading We have put back the ARI (CIMS). When we did that the reading of the Aethalometer webt to >10000;
    2019-10-24 04:38 [view ] -14.3497 121.2672 CIMS [view] Maintenance AIRBOX_in2019_v06 Inlet removed lab air entering systen
    2019-10-24 04:50 [view ] -14.3385 121.2898 SMPS [view] Fault AIRBOX_in2019_v06 leak Branka was pulling NAIS tubes off and disconnected something. Stopped sampling
    2019-10-24 05:01 [view ] -14.3145 121.2907 SBP [view] warning GSM_in2019_v06 card 8 - error channel 3 ; warning channel 4
    2019-10-24 05:22 [view ] -14.2655 121.2908 SMPS [view] Start AIRBOX_in2019_v06 Restarted after reconnecting
    2019-10-24 05:22 [view ] -14.2643 121.2908 VH-TDMA [view] Start AIRBOX_in2019_v06 Restarted to sync with SMPS Restarted from 523
    2019-10-24 05:26 [view ] -14.2550 121.2908 CIMS [view] Start AIRBOX_in2019_v06 started sampling all instruments sampling now outside air
    2019-10-24 05:27 [view ] -14.2538 121.2908 MAAP [view] Outage in2019_v06_Atmospherics Stopped operation temporarily to explore MAAP menu for pump control
    2019-10-24 10:30 [view ] -14.2512 121.1958 Microbiology_in2019_v06
    2019-10-24 10:30 [view ] -14.2512 121.1958 Microbiology_in2019_v06
    2019-10-24 10:30 [view ] -14.2512 121.1958 Microbiology_in2019_v06
    2019-10-24 10:57 [view ] -14.2507 121.1960 VH-TDMA [view] Fault AIRBOX_in2019_v06 AIM stopped scanning at 545 Restarting from 545
    2019-10-24 11:13 [view ] -14.2508 121.1960 Underway Merinda McMahon Hydrochem Lab : TSG16 Sample TSG_Samples_in2019_v06
    2019-10-24 11:15 [view ] -14.2508 121.1962 Deployed WeatherBalloon_in2019_v06
    2019-10-24 11:17 [view ] -14.2508 121.1962 Underway Merinda McMahon Hydrochem Lab : TSG17 Sample TSG_Samples_in2019_v06
    2019-10-24 11:17 [view ] -14.2508 121.1962 Underway Merinda McMahon Hydrochem Lab : TSG18 Sample TSG_Samples_in2019_v06
    2019-10-24 12:31 [view ] -14.2520 121.1975 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_017.asvp
    2019-10-24 15:40 [view ] -14.2620 121.1252 EM122 [view] Crash GSM_in2019_v06 Qinsy sound grid had crashed - restart with grid_2
    2019-10-24 23:17 [view ] -14.2703 121.2117 Deployed WeatherBalloon_in2019_v06
    2019-10-24 23:18 [view ] -14.2705 121.2118 APS [view] AIRBOX_in2019_v06 Logged on remotely, AIM crashed. Needed to reinstall the software for it to launch correctly. Something corrupted when I logged in remotely...
    2019-10-25 00:19 [view ] -14.2747 121.2130 EM122 [view] Stop GSM_in2019_v06 Stopped Logging still pinging VMP station deployment MVP deployment for 24 hrs start 0510.
    2019-10-25 00:33 [view ] -14.2733 121.2132 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Dailt maintenance Cheked V-flow 4.03lpm Filling water in humidifier
    2019-10-25 00:54 [view ] -14.2702 121.2127 SMPS [view] Maintenance AIRBOX_in2019_v06 Starting new file name 20191025.s80
    2019-10-25 01:10 [view ] -14.2673 121.2113 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Restarted new file H2019025.s80
    2019-10-25 05:14 [view ] -14.2653 121.2187 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Ammonium sulpha scans
    2019-10-25 06:27 [view ] -14.2730 121.2315 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Replaced sillica gell on H-side
    2019-10-25 06:59 [view ] -14.2758 121.2368 SMPS [view] Restart AIRBOX_in2019_v06 A vacuum line fell of and the SMPS stoped couting - repaired and restarted
    2019-10-25 09:17 [view ] -14.2882 121.2608 POSMV [view] new usb GSM_in2019_v06
    2019-10-25 10:30 [view ] -14.2937 121.2662 Both Drop in2019_v06_VSAT Signal was good, but speed was <100kbps
    2019-10-25 11:13 [view ] -14.2957 121.2615 Deployed WeatherBalloon_in2019_v06
    2019-10-25 11:33 [view ] -14.2950 121.2578 VH-TDMA [view] Change AIRBOX_in2019_v06 Switched back to outdoor sampling from 171 on VH-TDMA and 124 on SMPS
    2019-10-25 13:30 [view ] -14.2907 121.2375 Both Start in2019_v06_VSAT Connection recovered From Acutec: Global Eagle report that they have an issue in their network that is affecting multiple vessels and are working on it. They haven& 39;t provided an ETA yet. Sorry about this. We will keep you updated.
    2019-10-25 13:48 [view ] -14.2898 121.2337 EM122 [view] Start GSM_in2019_v06 heading west still on VMP profiles
    2019-10-25 14:39 [view ] -14.2867 121.2260 Both Beam switch in2019_v06_VSAT switch beam back to 180E to improve speed Speeds on 183E were ~2Mbps and speeds on 180E were ~5Mbps
    2019-10-25 15:00 [view ] -14.2853 121.2240 Both Auto Trim in2019_v06_VSAT auto trim after recovered connection and beam switch
    2019-10-25 16:57 [view ] -14.2795 121.2097 EM122 [view] Stop GSM_in2019_v06 stop logginh on ship turning back during VMP deployments
    2019-10-25 18:20 [view ] -14.3497 121.3110 EM122 [view] Start GSM_in2019_v06 Started logging. TRIAXUS resumed
    2019-10-25 23:15 [view ] -14.3493 121.3108 Deployed WeatherBalloon_in2019_v06
    2019-10-25 23:54 [view ] -14.2892 121.3447 CPC3772 [view] Change AIRBOX_in2019_v06 Liquid level Auto fill liquid level was off. Water removal was on so all the buthaol was wasted. Turned auoto fill on, water removal off.
    2019-10-26 01:29 [view ] -14.1798 121.2323 VH-TDMA [view] Fault AIRBOX_in2019_v06 Reported a fault could not start scan Stoped after 441
    2019-10-26 01:32 [view ] -14.1798 121.2262 VH-TDMA [view] Start AIRBOX_in2019_v06 restarted from 442
    2019-10-26 01:35 [view ] -14.1797 121.2193 SMPS [view] Fault AIRBOX_in2019_v06 AIM stopped scanning at 286 AIM stoped also for the VH-TDMA at the same time. Restarting SMPS
    2019-10-26 03:33 [view ] -14.3488 121.2288 EM122 [view] warning GSM_in2019_v06 PU Sensor (PU Sensor) Echo Sounder EM710 and EM122. Frequency of received attitude datagrams on port COM2 is less than 90%of expected (Hz) 90/78 (1813) SIT aware, screenshot saved P; > Trevor Hudson
    2019-10-26 04:28 [view ] -14.3495 121.3708 CCNC [view] Maintenance in2019_v06_Atmospherics Miliq topup Ruhi edited this instrument selection from SMPS to CCNC
    2019-10-26 04:32 [view ] -14.3495 121.3857 CPC 3772 [view] Maintenance in2019_v06_Atmospherics Butinol Topup
    2019-10-26 06:36 [view ] -14.2942 121.7795 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_018.asvp
    2019-10-26 06:52 [view ] -14.2868 121.8317 Change WeatherBalloon_in2019_v06 RADIOSONDE STATION HEIGHT CHANGE GPS ANTENNA OFFSET WAS -22.66M NOW +6M BAROMETER OFFSET WAS -3.93M NOW -13.0 (Since we are using the aerosol lab pressure as our station pressure) STATION ALTITUDE UNCHANGED AT 23.47M LAUNCH SITE OFFSET UNCHANGD -19.72M
    2019-10-26 07:09 [view ] -14.2790 121.8870 EM122 [view] note GSM_in2019_v06 ping mode set to shallow - cats ears in data
    2019-10-26 07:22 [view ] -14.2623 121.9230 SBP [view] Start GSM_in2019_v06 restart loggin - external pinging
    2019-10-26 09:21 [view ] -14.0372 122.2265 EM122 [view] Line GSM_in2019_v06 stop 116 ; 117 on ctd station
    2019-10-26 09:26 [view ] -14.0380 122.2270 Microbiology_in2019_v06
    2019-10-26 09:26 [view ] -14.0380 122.2270 Microbiology_in2019_v06
    2019-10-26 09:26 [view ] -14.0380 122.2270 Microbiology_in2019_v06
    2019-10-26 10:37 [view ] -14.0427 122.2243 SMPS [view] Maintenance AIRBOX_in2019_v06 Changed file name
    2019-10-26 11:12 [view ] -14.0178 122.1993 Deployed WeatherBalloon_in2019_v06
    2019-10-26 11:28 [view ] -13.9903 122.1742 SMPS [view] AIRBOX_in2019_v06 Counts gone down almost half
    2019-10-26 11:31 [view ] -13.9863 122.1697 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_019.asvp
    2019-10-26 11:49 [view ] -13.9767 122.1600 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks STOPPED AFTER FROM 156
    2019-10-26 13:32 [view ] -13.9130 122.0900 MAAP [view] Change in2019_v06_Atmospherics Flow rate change Flow rate lowered to 700LM to increase effect of nafions
    2019-10-26 13:57 [view ] -13.9015 122.0780 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_019.asvp
    2019-10-26 15:51 [view ] -13.7993 121.9572 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_021.asvp
    2019-10-26 21:40 [view ] -14.2705 121.2118 APS [view] AIRBOX_in2019_v06 Came in to find PC was turned off - restarted PC and software...
    2019-10-26 22:24 [view ] -13.4962 121.6208 EM122 [view] Ping rate GSM_in2019_v06 Ping Mode Change MEDIUM to DEEP
    2019-10-26 23:13 [view ] -13.4882 121.6100 Deployed WeatherBalloon_in2019_v06
    2019-10-27 00:14 [view ] -13.4395 121.5502 MAAP [view] Change in2019_v06_Atmospherics Changed MAAP flow back to 1000 LPH Came in to find Will had changed the flow rate down to 700 LPH about 11 hours ago and the MAAP is now throwing errors and not maintaining flow - same as previous. I& 39;ve changed it back and restarted the instrument to clear the persistent errors.
    2019-10-27 00:26 [view ] -13.4435 121.5493 VH-TDMA [view] Start AIRBOX_in2019_v06 RESTARTED Labview 00:31 Chamged log file
    2019-10-27 00:34 [view ] -13.4473 121.5492 CPC3772 [view] Start AIRBOX_in2019_v06 Restarting AIM changing file
    2019-10-27 00:39 [view ] -13.4555 121.5483 SMPS [view] Start AIRBOX_in2019_v06 Restarting AIM new file 20191027.s80
    2019-10-27 01:12 [view ] -13.4897 121.5302 EM122 [view] Stop GSM_in2019_v06 Stopped Logging still pinging CTD time series station Commencing 0130 UTC for 50 hours.
    2019-10-27 01:17 [view ] -13.4897 121.5300 SBP [view] Stop GSM_in2019_v06 Stopped logging Stopped for CTD time series for 50 hours starting 0130 UTC
    2019-10-27 07:21 [view ] -13.4888 121.5302 VH-TDMA [view] Start AIRBOX_in2019_v06 Turned back to atmospheric
    2019-10-27 07:22 [view ] -13.4888 121.5302 Microbiology_in2019_v06
    2019-10-27 07:22 [view ] -13.4888 121.5302 Microbiology_in2019_v06
    2019-10-27 07:22 [view ] -13.4888 121.5302 Microbiology_in2019_v06
    2019-10-27 10:27 [view ] -13.4885 121.5302 SBP [view] Start GSM_in2019_v06 stil on 50 hour station
    2019-10-27 10:49 [view ] -13.4890 121.5310 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_012.asvp
    2019-10-27 10:50 [view ] -13.4890 121.5310 EM122 [view] Start GSM_in2019_v06 start logging for at least 24 hours on station to compare gps tides!!!
    2019-10-27 11:16 [view ] -13.4902 121.5317 Deployed WeatherBalloon_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 121.5302 Microbiology_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 Microbiology_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 Microbiology_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 Microbiology_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 121.5302 Microbiology_in2019_v06
    2019-10-27 13:30 [view ] -13.4900 121.5302 Microbiology_in2019_v06
    2019-10-27 16:06 [view ] -13.4895 121.5297 Oxygen Analyser [view] Change in2019_v06_Atmospherics connected line to ACL Manifold
    2019-10-27 16:07 [view ] -13.4895 121.5297 Air Chem Manifold Change in2019_v06_Atmospherics Oxygen analyser oxygen analyser added to the manifold port 8
    2019-10-27 17:47 [view ] -13.4898 121.5302 Underway Christine Rees Hydrochem Lab : TSG19 Sample TSG_Samples_in2019_v06
    2019-10-27 17:49 [view ] -13.4898 121.5302 Underway Christine Rees Hydrochem Lab : TSG20 Sample TSG_Samples_in2019_v06
    2019-10-27 17:53 [view ] -13.4898 121.5302 Underway Christine Rees Hydrochem Lab : TSG21 Sample TSG_Samples_in2019_v06
    2019-10-27 23:15 [view ] -13.4893 121.5302 Deployed WeatherBalloon_in2019_v06
    2019-10-28 03:33 [view ] -13.4897 121.5302 POSMV [view] warning GSM_in2019_v06 Position Error POSMV Position Error
    2019-10-28 04:59 [view ] -13.4900 121.5302 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks Flows OK aerosol 0.27lpm, changed filename 20191028.s80
    2019-10-28 05:14 [view ] -13.4900 121.5302 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_021.asvp still on first 50 hour station -
    2019-10-28 08:25 [view ] -13.4888 121.5312 EM122 [view] Line GSM_in2019_v06 after syncing sbp to stop interference - no external trigger for em122
    2019-10-28 08:27 [view ] -13.4888 121.5310 SBP [view] Line GSM_in2019_v06 7 ; trigger fixed rate
    2019-10-28 11:15 [view ] -13.4890 121.5298 Deployed WeatherBalloon_in2019_v06
    2019-10-28 12:13 [view ] -13.4883 121.5300 Underway Merinda McMahon Hydrochem Lab : TSG22 Sample TSG_Samples_in2019_v06
    2019-10-28 12:16 [view ] -13.4883 121.5302 Underway Merinda McMahon Hydrochem Lab : TSG23 Sample TSG_Samples_in2019_v06
    2019-10-28 12:21 [view ] -13.4883 121.5300 Underway Merinda McMahon Hydrochem Lab : TSG24 Sample TSG_Samples_in2019_v06
    2019-10-28 12:34 [view ] -13.4892 121.5302 Aerosol Lab [view] Change in2019_v06_Atmospherics Air conditioning vent direction changed I changed the direction of this a few days ago so that it wasn& 39;t directly blowing onto the PTRMS line, since it was causing condensation. I think this meant it was blowing directly onto the MAAP and aerosol sample lines instead, which increased the RH in those lines to 60%. I think will came in about an hour or so ago and redirected one of them down again onto the PTRMS line, which has resulted in condensation again. I have changed it back for now. Now 12:42 - I have just added a bunch of towels over the insulated PTRMS line and pointed the AC fan down.
    2019-10-28 19:32 [view ] -13.4888 121.5317 Underway Christine Rees Hydrochem Lab : TSG25 Sample TSG_Samples_in2019_v06 tsg
    2019-10-28 19:35 [view ] -13.4890 121.5317 Underway Christine Rees Hydrochem Lab : TSG26 Sample TSG_Samples_in2019_v06
    2019-10-28 19:37 [view ] -13.4890 121.5317 Underway Christine Rees Hydrochem Lab : TSG27 Sample TSG_Samples_in2019_v06
    2019-10-28 23:14 [view ] -13.4903 121.5283 Deployed WeatherBalloon_in2019_v06
    2019-10-28 23:44 [view ] -13.4888 121.5292 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks All OK, see excell file
    2019-10-28 23:52 [view ] -13.4883 121.5287 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Checking flows Maintenance that is done every second day, see excell file
    2019-10-29 00:05 [view ] -13.4883 121.5282 SMPS [view] AIRBOX_in2019_v06 drsaining CPC Restarted both labview and AIM. Draining 3772 on the H-side and put it on water removal
    2019-10-29 01:30 [view ] -13.4895 121.5302 Microbiology_in2019_v06
    2019-10-29 01:30 [view ] -13.4895 121.5302 Microbiology_in2019_v06
    2019-10-29 01:30 [view ] -13.4895 121.5302 Microbiology_in2019_v06
    2019-10-29 03:00 [view ] -13.5153 121.5745 EM122 [view] Start GSM_in2019_v06 Transit to new Time Series site Recording .grid file on qinsy started.
    2019-10-29 04:12 [view ] -13.6517 121.7683 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_032.asvp Applied
    2019-10-29 04:45 [view ] -13.7163 121.8527 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_022.asvp
    2019-10-29 05:46 [view ] -13.7975 121.9580 EM122 [view] Line GSM_in2019_v06 starting second 50 hour station
    2019-10-29 09:02 [view ] -13.7985 121.9563 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_034.asvp
    2019-10-29 09:59 [view ] -13.7993 121.9570 Microbiology_in2019_v06
    2019-10-29 09:59 [view ] -13.7993 121.9570 Microbiology_in2019_v06
    2019-10-29 09:59 [view ] -13.7993 121.9570 Microbiology_in2019_v06
    2019-10-29 10:10 [view ] -13.7993 121.9570 VH-TDMA [view] Change AIRBOX_in2019_v06 Added 25nm size Observed a nucleation mode at ~25nm. Doing following sizes 25, 50, 100, 150nm from 175
    2019-10-29 11:13 [view ] -13.7990 121.9587 Deployed WeatherBalloon_in2019_v06
    2019-10-29 11:25 [view ] -13.7988 121.9593 VH-TDMA [view] Change AIRBOX_in2019_v06 Changed sizes to 30, 50, 100, 150nm There were very few particles in the 25nm size range
    2019-10-29 14:59 [view ] -13.7987 121.9585 SBP [view] Stop GSM_in2019_v06 on second 50 hour station
    2019-10-29 15:20 [view ] -13.7973 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_038.asvp
    2019-10-29 15:51 [view ] -13.7978 121.9577 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_037.asvp
    2019-10-29 21:59 [view ] -13.7995 121.9575 Microbiology_in2019_v06
    2019-10-29 21:59 [view ] -13.7995 121.9575 Microbiology_in2019_v06
    2019-10-29 22:21 [view ] -13.7997 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_041.asvp Applied
    2019-10-29 23:14 [view ] -13.7980 121.9582 SMPS [view] Maintenance AIRBOX_in2019_v06 Daiy checks
    2019-10-29 23:14 [view ] -13.7980 121.9582 Deployed WeatherBalloon_in2019_v06
    2019-10-29 23:36 [view ] -13.7982 121.9592 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Added water to humidifier
    2019-10-30 01:42 [view ] -13.7980 121.9578 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Replacing dryer with fresh silica gell
    2019-10-30 02:37 [view ] -13.7977 121.9598 VH-TDMA [view] Fault AIRBOX_in2019_v06 CPC stoped couting Checkibg fault and stoped software
    2019-10-30 03:58 [view ] -13.7970 121.9595 Microbiology_in2019_v06
    2019-10-30 03:58 [view ] -13.7970 121.9595 Microbiology_in2019_v06
    2019-10-30 03:58 [view ] -13.7970 121.9595 Microbiology_in2019_v06
    2019-10-30 04:14 [view ] -13.7970 121.9595 VH-TDMA [view] Restart AIRBOX_in2019_v06 The humidity was stuck at 94%. Going slowly down so restarting the scanning. still at 30, 50, 100,150nm
    2019-10-30 05:13 [view ] -13.7975 121.9585 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_045.asvp
    2019-10-30 05:43 [view ] -13.7978 121.9575 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Humidity playing Moved the critical orrifice down next to the humidifier
    2019-10-30 08:15 [view ] -13.7990 121.9573 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_046.asvp
    2019-10-30 08:16 [view ] -13.7990 121.9572 POSMV [view] Other GSM_in2019_v06 accuracy position red
    2019-10-30 08:32 [view ] -13.7988 121.9570 POSMV [view] note GSM_in2019_v06 position accuracy ok for now
    2019-10-30 09:08 [view ] -13.7978 121.9577 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_047.asvp
    2019-10-30 10:15 [view ] -13.7965 121.9557 VH-TDMA [view] Start AIRBOX_in2019_v06 Ramping 70-90 in 7200s from 46
    2019-10-30 10:34 [view ] -13.7980 121.9578 Aerosol Lab [view] in2019_v06_Atmospherics Wrapped the PTRMS line in bubble wrap and readjusted the AC vents to the correct downward direction again
    2019-10-30 11:13 [view ] -13.7980 121.9580 Deployed WeatherBalloon_in2019_v06
    2019-10-30 14:52 [view ] -13.7985 121.9595 Ozone Monitor [view] Outage in2019_v06_Atmospherics inlet off inlet switched off to find issues with flow rate, no observed changes upstream of the Tee
    2019-10-30 15:05 [view ] -13.7983 121.9590 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_049.asvp
    2019-10-30 15:39 [view ] -13.7975 121.9587 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_050.asvp
    2019-10-30 23:06 [view ] -13.7982 121.9577 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Ammonium sulpha scans at RH90 from 304
    2019-10-30 23:09 [view ] -13.7982 121.9575 SMPS [view] Maintenance AIRBOX_in2019_v06 File change in AIM
    2019-10-30 23:12 [view ] -13.7982 121.9577 Deployed WeatherBalloon_in2019_v06
    2019-10-30 23:34 [view ] -13.7985 121.9583 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_054.asvp Applied
    2019-10-30 23:35 [view ] -13.7983 121.9583 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
    2019-10-30 23:58 [view ] -13.7978 121.9578 VH-TDMA [view] Start AIRBOX_in2019_v06 restarted after daily checks
    2019-10-31 05:55 [view ] -13.7978 121.9577 Microbiology_in2019_v06
    2019-10-31 05:55 [view ] -13.7978 121.9577 Microbiology_in2019_v06
    2019-10-31 05:55 [view ] -13.7978 121.9577 Microbiology_in2019_v06
    2019-10-31 05:55 [view ] -13.7978 121.9577 Microbiology_in2019_v06
    2019-10-31 05:55 [view ] -13.7978 121.9577 Microbiology_in2019_v06
    2019-10-31 06:37 [view ] -13.7973 121.9567 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_057.asvp
    2019-10-31 08:25 [view ] -13.7972 121.9593 SBP [view] Line GSM_in2019_v06 8 - about to leave sampling site -
    2019-10-31 08:36 [view ] -13.8077 121.9698 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_059.asvp
    2019-10-31 09:08 [view ] -13.8690 122.0380 CPC3772 [view] Fault AIRBOX_in2019_v06 CPC to hot have to move it
    2019-10-31 10:30 [view ] -14.0225 122.2085 CPC3772 [view] Start AIRBOX_in2019_v06 restarted cooled the instrunent and restarting cant find a place to move it
    2019-10-31 10:40 [view ] -14.0322 122.2203 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_023.asvp
    2019-10-31 11:13 [view ] -14.0360 122.2247 Deployed WeatherBalloon_in2019_v06
    2019-10-31 13:10 [view ] -13.9727 122.1550 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_023.asvp
    2019-10-31 15:43 [view ] -13.8527 122.0218 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_025.asvp
    2019-10-31 22:39 [view ] -13.5328 121.6528 EM122 [view] SVP GSM_in2019_v06 in2019_v06_sst_25.asvp Applied
    2019-10-31 23:14 [view ] -13.4988 121.6172 Deployed WeatherBalloon_in2019_v06
    2019-10-31 23:27 [view ] -13.4993 121.6150 CPC3772 [view] Stop AIRBOX_in2019_v06 Stoped checkong crit orificr press Taking it into air chem lab for clean up
    2019-10-31 23:28 [view ] -13.4993 121.6148 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks
    2019-11-01 01:06 [view ] -13.4380 121.5502 SBP [view] warning GSM_in2019_v06 card 8 - error channel 3 ; warning channel 4
    2019-11-01 01:10 [view ] -13.4418 121.5493 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Conncted to vacuum
    2019-11-01 01:40 [view ] -13.5262 121.5270 CPC3772 [view] Start AIRBOX_in2019_v06 Connected to sampling manifold
    2019-11-01 02:18 [view ] -13.6453 121.4902 SMPS [view] Observation AIRBOX_in2019_v06 Flow changed after adding CPC Had to adjust flow
    2019-11-01 04:42 [view ] -14.0920 121.3525 CPC3772 [view] Change AIRBOX_in2019_v06 Put a dryer infront of the CPC
    2019-11-01 10:42 [view ] -14.2725 121.3240 CPC3772 [view] Start AIRBOX_in2019_v06 Taken of dryer Taken of dryer , counts close to the CPC in aerosol lab
    2019-11-01 11:13 [view ] -14.2725 121.3240 Deployed WeatherBalloon_in2019_v06
    2019-11-01 12:58 [view ] -14.3570 121.3733 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_060.asvp
    2019-11-01 23:07 [view ] -14.3567 121.3950 SMPS [view] Change AIRBOX_in2019_v06 Instaling an impactor
    2019-11-01 23:10 [view ] -14.3567 121.4022 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Daily cheks Refilled humidifier water
    2019-11-01 23:15 [view ] -14.3557 121.4143 Deployed WeatherBalloon_in2019_v06
    2019-11-01 23:16 [view ] -14.3548 121.4162 Other [view] GSM_in2019_v06 Bridge Echo Sounder Momentarily On for Testing from Bridge
    2019-11-01 23:40 [view ] -14.3043 121.4257 POSMV [view] warning GSM_in2019_v06 Position Error
    2019-11-01 23:53 [view ] -14.2748 121.4257 SMPS [view] Start AIRBOX_in2019_v06 Restarted with impactor
    2019-11-02 00:14 [view ] -14.2280 121.4258 VH-TDMA [view] Fault AIRBOX_in2019_v06 Labview not talking to RH meter Restarting labview
    2019-11-02 00:22 [view ] -14.2098 121.4258 VH-TDMA [view] Start AIRBOX_in2019_v06 Restarted after restarting LabView
    2019-11-02 09:08 [view ] -14.3625 121.3265 NAIS [view] Stop AIRBOX_in2019_v06 Removed from main inlet
    2019-11-02 11:13 [view ] -14.2025 121.3792 Deployed WeatherBalloon_in2019_v06
    2019-11-02 22:21 [view ] -14.2098 121.2912 POSMV [view] warning GSM_in2019_v06 Position Error
    2019-11-02 23:13 [view ] -14.3098 121.2695 Deployed WeatherBalloon_in2019_v06
    2019-11-03 04:41 [view ] -14.2828 121.3617 Microbiology_in2019_v06
    2019-11-03 04:41 [view ] -14.2828 121.3617 Microbiology_in2019_v06
    2019-11-03 04:41 [view ] -14.2828 121.3617 Microbiology_in2019_v06
    2019-11-03 05:00 [view ] -14.2832 121.3607 Underway Merinda McMahon Hydrochem Lab : TSG28 Sample TSG_Samples_in2019_v06
    2019-11-03 05:02 [view ] -14.2832 121.3605 Underway Merinda McMahon Hydrochem Lab : TSG29 Sample TSG_Samples_in2019_v06
    2019-11-03 05:04 [view ] -14.2832 121.3605 Underway Merinda McMahon Hydrochem Lab : TSG30 Sample TSG_Samples_in2019_v06
    2019-11-03 07:10 [view ] -14.2157 121.3503 EM122 [view] Other GSM_in2019_v06 in2019_v06_ctd_061.asvp
    2019-11-03 09:14 [view ] -14.2013 121.3422 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change All same as yesterday - see excell file
    2019-11-03 09:44 [view ] -14.2050 121.2815 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Check of flow rates all OK
    2019-11-03 09:58 [view ] -14.2322 121.2755 VH-TDMA [view] Start AIRBOX_in2019_v06 Restarted after flow check
    2019-11-03 10:05 [view ] -14.2478 121.2755 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_062.asvp
    2019-11-03 10:43 [view ] -14.3295 121.2758 VH-TDMA [view] Fault AIRBOX_in2019_v06 Low counts Since we checked the flow rates low counts checking it.
    2019-11-03 11:14 [view ] -14.3703 121.3113 WeatherBalloon_in2019_v06
    2019-11-03 18:45 [view ] -14.2133 121.3958 CPC 3772 [view] Maintenance in2019_v06_Atmospherics Filled Butinol
    2019-11-03 18:45 [view ] -14.2133 121.3950 CCNC [view] Maintenance in2019_v06_Atmospherics Miliq refill
    2019-11-03 22:59 [view ] -14.2980 121.4620 NAIS [view] Start AIRBOX_in2019_v06 Reconected NAIS
    2019-11-03 23:13 [view ] -14.2963 121.4627 Deployed WeatherBalloon_in2019_v06
    2019-11-03 23:44 [view ] -14.2922 121.4618 XBT [view] SVP GSM_in2019_v06 in2019_v06_xbt_025.asvp Applied
    2019-11-04 00:01 [view ] -14.2908 121.4620 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks and file name change
    2019-11-04 00:15 [view ] -14.2905 121.4617 O3 NOX Stop AIRBOX_in2019_v06 Stopping instrumentation for packup since instruments aren't working.
    2019-11-04 00:15 [view ] -14.2905 121.4617 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Daiy checks - added water to humdifier all OK, will stop lab view and change log file name
    2019-11-04 00:25 [view ] -14.2905 121.4617 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Changed file name
    2019-11-04 00:43 [view ] -14.2902 121.4613 Aerosol Lab [view] in2019_v06_Atmospherics Packing up AIRBOX O3 and NOx in aerosol lab
    2019-11-04 00:47 [view ] -14.2902 121.4613 Aerosol Lab [view] in2019_v06_Atmospherics Removed AIRBOX O3 exhaust line from butanol exhaust and plugged it with paper after a small butanol smell was detected in that corner
    2019-11-04 02:04 [view ] -14.2597 121.4603 APS [view] Stop AIRBOX_in2019_v06 Stopped and disconnected from inlet for PSL calibration
    2019-11-04 03:10 [view ] -14.2597 121.4603 APS [view] Start AIRBOX_in2019_v06 Reconnected to inlet and resumed normal sampling
    2019-11-04 11:13 [view ] -14.4273 121.4082 Deployed WeatherBalloon_in2019_v06
    2019-11-04 11:23 [view ] -14.4477 121.4315 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_026.asvp
    2019-11-04 12:27 [view ] -14.5838 121.5882 EM122 [view] SVP GSM_in2019_v06 in2019_v06_xbt_027.asvp
    2019-11-04 18:15 [view ] -14.5843 121.5490 Microbiology_in2019_v06
    2019-11-04 18:16 [view ] -14.5843 121.5490 Microbiology_in2019_v06
    2019-11-04 23:14 [view ] -14.4108 121.7623 Deployed WeatherBalloon_in2019_v06
    2019-11-05 00:02 [view ] -14.3125 121.8770 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Added water to humidifier and changed silica gell
    2019-11-05 00:36 [view ] -14.2433 121.9592 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-05 00:37 [view ] -14.2425 121.9602 CPC3772 [view] Restart AIRBOX_in2019_v06 Soped to sink with SMPS, restartted
    2019-11-05 03:37 [view ] -13.7970 121.9562 Underway Christine Rees Hydrochem Lab : TSG31 Sample TSG_Samples_in2019_v06
    2019-11-05 03:40 [view ] -13.7972 121.9562 Underway Christine Rees Hydrochem Lab : TSG32 Sample TSG_Samples_in2019_v06
    2019-11-05 03:41 [view ] -13.7973 121.9562 Underway Christine Rees Hydrochem Lab : TSG33 Sample TSG_Samples_in2019_v06
    2019-11-05 05:03 [view ] -13.7958 121.9580 SBP [view] Stop GSM_in2019_v06 stop logging on 50 hour site
    2019-11-05 06:03 [view ] -13.7952 121.9600 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_063.asvp
    2019-11-05 07:26 [view ] -13.8020 121.9535 CPC3772 [view] Fault AIRBOX_in2019_v06 Low count The count seems a bit low. Maybe needs drying.Will observe in th e next few hours
    2019-11-05 09:48 [view ] -13.7983 121.9580 CPC3772 [view] Fault AIRBOX_in2019_v06 Low counts Will put it overnight on dryer to recover the counts.
    2019-11-05 10:02 [view ] -13.7987 121.9582 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Drying out CPC I have put a dryer on the inlet of the CPC and taken it of line. CPC counts 387 cm-3; SMPScount before the CPC was disconected is 1.14e3cm-3 After the CPCrunning through dryer it counts 328cm-3
    2019-11-05 11:10 [view ] -13.7965 121.9575 VH-TDMA [view] Fault AIRBOX_in2019_v06 RH meter isreporting RH of 0
    2019-11-05 11:13 [view ] -13.7972 121.9570 Deployed WeatherBalloon_in2019_v06
    2019-11-05 11:20 [view ] -13.7980 121.9565 VH-TDMA [view] Fault AIRBOX_in2019_v06 restarted chilled mirror It was reporting temp of -100C. restarted and unpluged tep probe and pluged back again. Looks OK still in DCC mode
    2019-11-05 11:20 [view ] -13.7980 121.9567 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_064.asvp
    2019-11-05 11:39 [view ] -13.7977 121.9575 VH-TDMA [view] Start AIRBOX_in2019_v06 Restarted Labview Restarted from 218. Starting RH ~72
    2019-11-05 12:50 [view ] -13.7973 121.9563 Microbiology_in2019_v06
    2019-11-05 12:51 [view ] -13.7973 121.9563 Microbiology_in2019_v06
    2019-11-05 12:52 [view ] -13.7973 121.9563 Microbiology_in2019_v06
    2019-11-05 14:14 [view ] -13.7997 121.9565 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_066.asvp
    2019-11-05 22:16 [view ] -13.7988 121.9557 VH-TDMA [view] Fault AIRBOX_in2019_v06 Chilled mirror showin 0%
    2019-11-05 22:17 [view ] -13.7988 121.9557 CPC3772 [view] Restart AIRBOX_in2019_v06 Removing dryer
    2019-11-05 23:13 [view ] -13.7983 121.9580 Deployed WeatherBalloon_in2019_v06
    2019-11-06 00:20 [view ] -13.7995 121.9568 VH-TDMA [view] Outage AIRBOX_in2019_v06 Turned off The VH-TDMA has been turned off as the Chilled mirror is broken. Will try to replumb it with another RH sensor.
    2019-11-06 03:30 [view ] -13.7973 121.9575 Microbiology_in2019_v06
    2019-11-06 03:30 [view ] -13.7973 121.9575 Microbiology_in2019_v06
    2019-11-06 03:54 [view ] -13.7975 121.9575 Underway Christine Rees Hydrochem Lab : TSG34 Sample TSG_Samples_in2019_v06
    2019-11-06 03:56 [view ] -13.7975 121.9575 Underway Christine Rees Hydrochem Lab : TSG35 Sample TSG_Samples_in2019_v06
    2019-11-06 03:58 [view ] -13.7975 121.9575 Underway Christine Rees Hydrochem Lab : TSG36 Sample TSG_Samples_in2019_v06
    2019-11-06 04:29 [view ] -13.7977 121.9552 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_072
    2019-11-06 06:01 [view ] -13.7987 121.9597 MAAP [view] Outage in2019_v06_Atmospherics Disconnected from main line and turned off manifold tap to work on MAAP pump to reduce flow rate Back in service at 06:23
    2019-11-06 06:29 [view ] -13.7985 121.9598 Ozone Monitor [view] Maintenance in2019_v06_Atmospherics Disconnected the lines momentarily on each before the filter to check flow issue.
    2019-11-06 09:01 [view ] -13.7978 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_075_ed.asvp testing only using downcast data ie editing out first in water data and upcast - nb number of indexes in header is different than actual readings
    2019-11-06 11:13 [view ] -13.7977 121.9578 Deployed WeatherBalloon_in2019_v06
    2019-11-06 11:46 [view ] -13.7977 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_076.asvp
    2019-11-06 12:13 [view ] -13.7955 121.9585 POSMV [view] Start GSM_in2019_v06 usb logging new one 4
    2019-11-06 13:10 [view ] -13.7977 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_077.asvp
    2019-11-06 14:01 [view ] -13.7957 121.9588 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_078.asvp
    2019-11-06 16:58 [view ] -13.7998 121.9578 MAAP T&RH Sensor [view] Maintenance in2019_v06_Atmospherics Humidity approaching 50% - Flow Increased to 1.3l/m
    2019-11-06 20:17 [view ] -13.7972 121.9563 POSMV [view] Start GSM_in2019_v06 Start ethernet logging Suspected ethernet not logging since USB change.
    2019-11-06 20:43 [view ] -13.7972 121.9568 MAAP T&RH Sensor [view] Stop in2019_v06_Atmospherics Humidity persistently above 50% Shut down the instrument including the pump. Maintaining flow of air from the dryer
    2019-11-06 22:27 [view ] -13.7965 121.9568 MAAP [view] Start in2019_v06_Atmospherics Restarted after instructions for Ian McRobert 50% is safe. Outside spec for data quality, but safe.
    2019-11-06 23:13 [view ] -13.7975 121.9578 Deployed WeatherBalloon_in2019_v06
    2019-11-06 23:23 [view ] -13.4892 121.5302 Aerosol Lab [view] Change in2019_v06_Atmospherics Air conditioning vent direction changed slightly I discovered that the filters sitting under the AC were soaking wet this morning. Since there are no waves, its likely it was condensation. I have changed the direction slightly so its not directly on the cartridges. Not sure why this is the first time this has happened.
    2019-11-06 23:26 [view ] -13.7973 121.9577 VH-TDMA [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-06 23:29 [view ] -13.7973 121.9577 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
    2019-11-07 01:30 [view ] -13.7977 121.9578 Microbiology_in2019_v06
    2019-11-07 01:30 [view ] -13.7977 121.9578 Microbiology_in2019_v06
    2019-11-07 01:39 [view ] -13.7977 121.9577 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_083.asvp
    2019-11-07 01:43 [view ] -13.7975 121.9577 Underway Christine Rees Hydrochem Lab : TSG37 Sample TSG_Samples_in2019_v06
    2019-11-07 01:45 [view ] -13.7973 121.9578 Underway Christine Rees Hydrochem Lab : TSG38 Sample TSG_Samples_in2019_v06
    2019-11-07 01:46 [view ] -13.7973 121.9578 Underway Christine Rees Hydrochem Lab : TSG39 Sample TSG_Samples_in2019_v06
    2019-11-07 06:00 [view ] -13.7993 121.9553 Nephelometer [view] Observation in2019_v06_Atmospherics Neph hasn't done its calibration the past few days - CO2 tank has run out. Will is going to replace it this shift.
    2019-11-07 06:41 [view ] -13.7987 121.9577 Nephelometer [view] Maintenance in2019_v06_Atmospherics co2 tank replaced - co2 tank depleted, spare connected, and leak checked - accumulative flow meter reading 456 - accumulative meter reset
    2019-11-07 06:53 [view ] -13.7973 121.9583 CPC3772 [view] Change AIRBOX_in2019_v06 Setting double dryer Losses in second dryer ~50% not putting it n line
    2019-11-07 06:59 [view ] -13.7975 121.9587 CPC3772 [view] Change AIRBOX_in2019_v06 INstaled the RH probe inline after dryer
    2019-11-07 07:02 [view ] -13.7977 121.9590 CPC3772 [view] Change AIRBOX_in2019_v06 Placed the RH probe inline after the first drier
    2019-11-07 07:22 [view ] -13.7975 121.9597 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_086.asvp
    2019-11-07 07:24 [view ] -13.7973 121.9595 POSMV [view] warning GSM_in2019_v06 position accuracy red light
    2019-11-07 08:02 [view ] -13.7967 121.9592 POSMV [view] Other GSM_in2019_v06 position accuracy ok for now
    2019-11-07 08:42 [view ] -13.7982 121.9580 SBP [view] note GSM_in2019_v06 testing restarted SBP - no red warnings in card 8 4 and 5 -
    2019-11-07 11:13 [view ] -13.7992 121.9553 Deployed WeatherBalloon_in2019_v06
    2019-11-07 15:26 [view ] -13.7980 121.9578 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_090.asvp
    2019-11-07 21:30 [view ] -13.7982 121.9583 Microbiology_in2019_v06
    2019-11-07 21:30 [view ] -13.7982 121.9583 Microbiology_in2019_v06
    2019-11-07 23:12 [view ] -13.7990 121.9515 Deployed WeatherBalloon_in2019_v06
    2019-11-07 23:18 [view ] -13.8022 121.9350 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_094
    2019-11-08 00:09 [view ] -13.8490 121.7837 Tekran [view] Outage AIRBOX_in2019_v06 Tekran PC died yesterday at 00:25 UTC. Back running now Seems power button is dodgy. Turns off with barely a touch of the power button and takes about 8 seconds of holding the power button down to turn it on. Have covered up the power button now so it can& 39;t accidentally be touched.
    2019-11-08 00:09 [view ] -13.8498 121.7830 CPC3772 [view] Fault AIRBOX_in2019_v06 Low counts Low counts. CPC needs to be dried out. Putting a dryer in front of CPC.
    2019-11-08 00:20 [view ] -13.8775 121.7593 SMPS [view] AIRBOX_in2019_v06 Changed file name
    2019-11-08 00:41 [view ] -13.9323 121.7125 Aethelometer [view] Observation AIRBOX_in2019_v06 Tape advancing
    2019-11-08 00:55 [view ] -13.8490 121.7837 Tekran [view] Outage AIRBOX_in2019_v06 Changed power settings on Tekran PC so that power button does nothing (previuosly was set to go to sleep) and also set it so the screen wouldn't turn off.
    2019-11-08 03:58 [view ] -14.4182 121.3700 Microbiology_in2019_v06
    2019-11-08 04:01 [view ] -14.4182 121.3700 Underway Christine Rees Hydrochem Lab : TSG40 Sample TSG_Samples_in2019_v06
    2019-11-08 04:03 [view ] -14.4180 121.3700 Underway Christine Rees Hydrochem Lab : TSG41 Sample TSG_Samples_in2019_v06
    2019-11-08 04:04 [view ] -14.4180 121.3700 Underway Christine Rees Hydrochem Lab : TSG42 Sample TSG_Samples_in2019_v06
    2019-11-08 06:10 [view ] -14.4300 121.3873 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_095.asvp
    2019-11-08 06:11 [view ] -14.4303 121.3902 SBP [view] Start GSM_in2019_v06 leaving wirewalker retrieval - head for darwin!! maybe one more ctd
    2019-11-08 06:22 [view ] -14.4250 121.4223 CPC3772 [view] Change AIRBOX_in2019_v06 Removed drier. Counts back to normal
    2019-11-08 06:34 [view ] -14.4147 121.4590 Air Flask Fill Sample Taken in2019_v06_Atmospherics Filled two flasks - in airchem lab
    2019-11-08 08:06 [view ] -14.3283 121.7562 POSMV [view] warning GSM_in2019_v06 position accuracy red light
    2019-11-08 08:35 [view ] -14.3013 121.8490 POSMV [view] Other GSM_in2019_v06 position accuracy ok now
    2019-11-08 11:13 [view ] -13.9542 122.1900 Deployed WeatherBalloon_in2019_v06
    2019-11-08 14:18 [view ] -13.4997 122.5010 EM122 [view] SVP GSM_in2019_v06 test_15.asvp
    2019-11-08 14:18 [view ] -13.4997 122.5010 Microbiology_in2019_v06
    2019-11-08 14:27 [view ] -13.4993 122.5007 EM122 [view] SVP GSM_in2019_v06 in2019_v06_nowC_001.asvp created an asvp using nowcast data, aml value at 10 m and extended using values from previous ctd asvp!!
    2019-11-08 15:57 [view ] -13.4713 122.7165 EM122 [view] SVP GSM_in2019_v06 in2019_v06_ctd_096.asvp
    2019-11-08 19:12 [view ] -13.3885 123.3430 EM122 [view] Ping rate GSM_in2019_v06 Ping Mode Change MEDIUM to SHALLOW
    2019-11-08 22:24 [view ] -13.3033 123.9863 APS [view] Maintenance AIRBOX_in2019_v06 Restarted software as part of routine maintenance
    2019-11-08 22:55 [view ] -13.2897 124.0895 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-08 23:11 [view ] -13.2822 124.1465 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
    2019-11-08 23:13 [view ] -13.2813 124.1527 Deployed WeatherBalloon_in2019_v06
    2019-11-08 23:35 [view ] -13.2710 124.2300 EM122 [view] note GSM_in2019_v06 Ship SBES turned on
    2019-11-09 00:05 [view ] -13.2572 124.3347 CPC3772 [view] Fault AIRBOX_in2019_v06 Low counts CPC needs drying. Swaping CPC& 39;s. Using the H-tdma one instead. File name will be HCPC....
    2019-11-09 00:17 [view ] -13.2517 124.3757 CPC 3772 [view] Fault in2019_v06_Atmospherics MFC not reaching setpoint since yesterday. Even if I increase the setpoint by 0.1 LPM, the flow doesnt go above 1.02 LPM (compared to 1.04 set point). This is usually bang on and very stable, but the measured reading is very unstable. I drained the catchpot and also temporarily put it on the strong vacuum with no change from either. I disconnected the MFC from the CPC and the flowrate went up to the setpoint easily - there is a blockage upstream of the MFC. CPC nozzle pressure was 2.6 kPa. Disconnected CPC from inlet line - flows are slightly better but still not reaching setpoint. Taking offline to clean the nozzle. Found nozzle had something in it which was cleaned out with the ultrasonic and a kimwipe. MFC is reaching setpoint again and all looks good. CPC nozzle pressure 2.4 kPa - not a huge difference. Back online and connected to nozzle at 01:09.
    2019-11-09 00:56 [view ] -13.2450 124.4550 EM122 [view] Stop GSM_in2019_v06 Stopped Recording switched to EM710
    2019-11-09 00:57 [view ] -13.2445 124.4558 EM710 [view] Start GSM_in2019_v06 line started ADCP turned off and Keels raised.
    2019-11-09 00:58 [view ] -13.2443 124.4563 EM710 [view] SVP GSM_in2019_v06 in2019_v06_sst_026.asvp Applied
    2019-11-09 00:59 [view ] -13.2443 124.4568 EM710 [view] note GSM_in2019_v06 Qinsy Crashed and restarted
    2019-11-09 02:03 [view ] -13.2030 124.6412 EM710 [view] Stop GSM_in2019_v06 Stopped pinging and recording EM710 ADCP turned back on.
    2019-11-09 02:12 [view ] -13.1967 124.6755 EM122 [view] Start GSM_in2019_v06 EM122 Started
    2019-11-09 02:40 [view ] -13.1775 124.7807 EK60 [view] Stop GSM_in2019_v06 require adcp data
    2019-11-09 02:49 [view ] -13.1710 124.8162 EM122 [view] Stop GSM_in2019_v06 Stopped logging depth 113m Cannot use EM710, EM122 too shallow.
    2019-11-09 03:32 [view ] -13.1413 124.9788 SBP [view] Stop GSM_in2019_v06 Network Error Trouble shooting a network error. Restart
    2019-11-09 03:40 [view ] -13.1355 125.0110 SBP [view] Start GSM_in2019_v06
    2019-11-09 04:53 [view ] -13.0848 125.2888 CPC 3772 [view] Outage in2019_v06_Atmospherics Software hasn't been communicating with the CPC since the nozzle clean. Ian is logged on remotely to get it going again. When I Plugged the serial plug back into the MFC, it sparked a bit. Ian has fixed it remotely by sending the instrument a "SSTART,0" and "SSTART,1" set of commands to wake it back up again.
    2019-11-09 06:46 [view ] -13.0058 125.7217 Picarro Spectrometer [view] Outage in2019_v06_Atmospherics Stopped to check t&rh dowty seals
    2019-11-09 11:13 [view ] -12.8542 126.7038 Deployed WeatherBalloon_in2019_v06 The sounding software failed soon after launch. The result is that we only got the first 10 minutes of data.
    2019-11-09 23:56 [view ] -12.4290 129.5855 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-10 00:01 [view ] -12.4262 129.6048 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
    2019-11-10 00:03 [view ] -12.4252 129.6120 Aethelometer [view] Maintenance AIRBOX_in2019_v06 Download of data Downloaded data and restarted
    2019-11-10 00:54 [view ] -12.3983 129.7935 Tekran [view] Maintenance AIRBOX_in2019_v06 Changing the soda lime
    2019-11-10 03:08 [view ] -12.3262 130.2825 POSMV [view] Stop GSM_in2019_v06 end of logging
    2019-11-10 03:09 [view ] -12.3257 130.2857 SBP [view] Stop GSM_in2019_v06 end of voyage
    2019-11-10 06:14 [view ] -12.3088 130.6337 SMPS [view] Fault AIRBOX_in2019_v06 Placed dry air on Nafion CPC shows large counts after I placed dry air on nafion to blow
    2019-11-10 06:24 [view ] -12.3122 130.6435 SMPS [view] Start AIRBOX_in2019_v06 Restarted
    2019-11-10 07:18 [view ] -12.3567 130.7228 CPC 3772 [view] Outage in2019_v06_Atmospherics MFC died on the CPC...
    2019-11-10 22:16 [view ] -12.4723 130.8455 Aethelometer [view] Stop AIRBOX_in2019_v06 Turnod off to save tape while
    2019-11-10 22:16 [view ] -12.4723 130.8455 Aethelometer [view] Stop AIRBOX_in2019_v06 Turnod off to save tape while in port
    2019-11-10 22:16 [view ] -12.4723 130.8455 Aethelometer [view] Stop AIRBOX_in2019_v06 Turnod off to save tape while in port
    2019-11-10 22:16 [view ] -12.4723 130.8455 Aethelometer [view] Stop AIRBOX_in2019_v06
    2019-11-10 22:36 [view ] -12.4723 130.8455 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change All ok
    2019-11-10 22:43 [view ] -12.4723 130.8455 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapping CPCs CSIRO sampling
    2019-11-10 22:50 [view ] -12.4723 130.8455 CPC3772 [view] Start AIRBOX_in2019_v06 started sampling csiro cpc
    2019-11-11 05:10 [view ] -12.4723 130.8455 POSMV [view] Start GSM_in2019_v06 Start logging PosMV ethernet and usb
    2019-11-11 05:12 [view ] -12.4723 130.8455 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_sst_035.asvp
    2019-11-11 05:43 [view ] -12.4723 130.8455 CPC 3772 [view] Start in2019_v06_Atmospherics MFC repaired The CPC MFC PSU failed. Likely due to the way the serial cable was made - unused wires connected to MFC power pins may have been shorting. PSU replaced, cable remade
    2019-11-11 06:05 [view ] -12.4723 130.8455 XBT [view] TEST GSM_in2019_v06 test XBT with dummy probe. Noticed position and date/time don't update for test drop
    2019-11-11 11:02 [view ] -12.4567 130.8073 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_sst_027.asvp applied
    2019-11-11 11:04 [view ] -12.4532 130.8043 EM710 [view] Start GSM_in2019_v06 Start logging Line 0056
    2019-11-11 11:22 [view ] -12.4088 130.7653 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_sst_028.asvp applied
    2019-11-11 11:35 [view ] -12.3773 130.7425 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_sst_029.asvp applied
    2019-11-11 11:38 [view ] -12.3692 130.7370 SBP [view] Start GSM_in2019_v06
    2019-11-11 13:16 [view ] -12.2175 130.4680 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_sst_030.asvp applied
    2019-11-11 17:20 [view ] -11.8220 129.9590 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v04_sst_031.asvp applied
    2019-11-11 21:32 [view ] -11.0918 130.0000 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v04_sst_032.asvp applied
    2019-11-11 22:56 [view ] -10.8475 130.0830 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v04_sst_033.asvp applied
    2019-11-11 23:05 [view ] -10.8468 130.1158 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily checks and file name change
    2019-11-11 23:06 [view ] -10.8468 130.1178 CPC3772 [view] AIRBOX_in2019_v06 started sampling csiro cpc
    2019-11-11 23:15 [view ] -10.8465 130.1288 Deployed WeatherBalloon_in2019_v06 Practice Flight 1 of 3
    2019-11-11 23:16 [view ] -10.8465 130.1298 Aethelometer [view] Start AIRBOX_in2019_v06 Turned on
    2019-11-11 23:32 [view ] -10.8460 130.1798 SBP [view] Stop GSM_in2019_v06 TX Power Red
    2019-11-11 23:39 [view ] -10.8455 130.2043 POSMV [view] Other GSM_in2019_v06 PosMV in Marinestar VBS Nav Status
    2019-11-11 23:49 [view ] -10.8450 130.2378 SBP [view] Start GSM_in2019_v06 restart logging after restart of sbp
    2019-11-12 00:48 [view ] -10.8418 130.4323 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v04_sst_034.asvp applied
    2019-11-12 03:16 [view ] -10.8340 130.9083 Stabilised Platform Stop in2019_v06_Atmospherics Stopped for cloud radar maintenance
    2019-11-12 03:39 [view ] -10.8328 130.9808 EM710 [view] Ping rate GSM_in2019_v06 Remove EM710 from Ksync
    2019-11-12 03:42 [view ] -10.8327 130.9878 Stabilised Platform Start in2019_v06_Atmospherics Restart following cloud radar maintenance
    2019-11-12 04:23 [view ] -10.8305 131.1210 Stabilised Platform Change in2019_v06_Atmospherics Offset correction factor set to 1.5 Offset correction factor reduced from 3.0 to 1.5 to reduce overshoot
    2019-11-12 05:13 [view ] -10.8280 131.2722 Deployed WeatherBalloon_in2019_v06 Practice Flight 2 of 3
    2019-11-12 09:32 [view ] -10.8147 132.0887 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_sst_036.asvp
    2019-11-12 11:17 [view ] -10.8090 132.3868 Deployed WeatherBalloon_in2019_v06 Practice Flight 3 of 3
    2019-11-12 16:30 [view ] -10.7973 133.1518 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_sst_037.asvp
    2019-11-12 18:15 [view ] -11.0093 133.3165 MAAP [view] Maintenance in2019_v06_Atmospherics flow rate change testing @flow = 1000l/hr, reg = 33.7%. Stable @flow = 900l/hr, reg = 29.2%. Stable @flow = 800l/hr, reg = 21.8%. Stable @flow = 700l/hr, reg = ---------- Unstable @flow = 750l/hr, reg <20% Unstable @flow = 790l/hr, reg = 19.6%. Stable @flow = 780l/hr, reg = 19.2%. Stable Test completed @ 0635UTC
    2019-11-12 18:41 [view ] -11.0712 133.3532 Ozone Monitor [view] Maintenance in2019_v06_Atmospherics Water trap emptied
    2019-11-12 19:43 [view ] -11.1995 133.4303 MAAP [view] Stop in2019_v06_Atmospherics stopped for outlet modification Adding speed controller between MAAP outlet and pump. Suspect some restriction here may allow lower flows to be stable
    2019-11-12 19:44 [view ] -11.1995 133.4305 EM710 [view] Stop GSM_in2019_v06 Stop pinging for EM710. At Station
    2019-11-12 19:45 [view ] -11.1997 133.4305 SBP [view] Stop GSM_in2019_v06 Stop pinging forSBP120. At Station
    2019-11-12 19:45 [view ] -11.1997 133.4305 MAAP [view] Start in2019_v06_Atmospherics restart following outlet modification speed controller added, left fully open flow regulator @33.7%, flow 1000l/hr, as before
    2019-11-12 19:47 [view ] -11.1998 133.4305 MAAP [view] Maintenance in2019_v06_Atmospherics Flow rate change tests Sample humidity 50% at start of test Flow rate: @1000l/hr, reg 33.7%, Stable @800l/hr, reg 20.9%, stable speed controller adjusted (orifice reduced) @800l/hr, reg 33.9%, stable @750l/hr, reg 30.6%, stable @700l/hr, reg 25.9%, stable @650l/hr, reg 18.0%, stable speed controller adjusted (orifice reduced) @650l/hr, reg 34.0%, stable sample humidity 39% @600l/hr, reg 28.7%, stable speed controller adjusted (orifice reduced) @550l/hr, reg 34.0%, stable @500l/hr, reg25.5%, stable sample humidity 33.7% Flow rate left at 500l/hr
    2019-11-12 19:56 [view ] -11.2010 133.4307 Underway Stephen Tibben Hydrochem Lab : TSG43 Sample TSG_Samples_in2019_v06
    2019-11-12 19:58 [view ] -11.2012 133.4308 Underway Stephen Tibben Hydrochem Lab : TSG44 Sample TSG_Samples_in2019_v06
    2019-11-12 20:00 [view ] -11.2013 133.4308 Underway Stephen Tibben Hydrochem Lab : TSG45 Sample TSG_Samples_in2019_v06
    2019-11-12 20:13 [view ] -11.2030 133.4312 MAAP [view] Change in2019_v06_Atmospherics MAAP flow rate reduced to 500l/hr Based on testing, the MAAP flow rate has been reduced to 500L/hr, from1000L/hr. To ensure VSCC is at correct flow (1000L/hr), a bypass is running at 7.33l/min, and the sample line monitoring (t,rh,p) at 1l/min 7.33+1+8.33 = 16.66l/min = 1000L/hr Sample humidity 33.7%, Dew Point 8.75C. External air dew point = 23.5C
    2019-11-12 20:58 [view ] -11.2062 133.4335 Exhaust Detection Change in2019_v06_Atmospherics Min wind speed set to 0 We will be on station for 5 weeks, so the wind speed is too restrictive
    2019-11-12 23:17 [view ] -11.2043 133.4337 Deployed WeatherBalloon_in2019_v06
    2019-11-13 01:10 [view ] -11.2051 -11.2052 Microbiology_in2019_v06
    2019-11-13 01:10 [view ] -11.2051 -11.2052 Microbiology_in2019_v06
    2019-11-13 02:16 [view ] -11.2058 133.4327 Deployed WeatherBalloon_in2019_v06
    2019-11-13 03:26 [view ] -11.2073 133.4320 Microbiology_in2019_v06
    2019-11-13 03:26 [view ] -11.2073 133.4320 Microbiology_in2019_v06
    2019-11-13 03:26 [view ] -11.2073 133.4320 Microbiology_in2019_v06
    2019-11-13 05:16 [view ] -11.2133 133.4310 Deployed WeatherBalloon_in2019_v06 5.15 (utc) (regular launch)
    2019-11-13 08:18 [view ] -11.2180 133.4340 Deployed WeatherBalloon_in2019_v06 08:15 (utc) launch
    2019-11-13 11:19 [view ] -11.2047 133.4325 Deployed WeatherBalloon_in2019_v06
    2019-11-13 14:15 [view ] -11.2038 133.4317 Deployed WeatherBalloon_in2019_v06
    2019-11-13 17:13 [view ] -11.2065 133.4327 Deployed WeatherBalloon_in2019_v06
    2019-11-13 19:01 [view ] -11.2115 133.4392 Aerosol Lab [view] Change in2019_v06_Atmospherics Insulation installed on nafions The sample line temperatures were fluctuating significantly due to the air conditioning. I have insulated the nafions as they are the largest surface. The temps are now stable/reflective of outside temp.
    2019-11-13 20:26 [view ] -11.2170 133.4455 Deployed WeatherBalloon_in2019_v06 Accidentally filled in surface station data from the launch 3 hours before into the sounding software after this launch. Clicked Apply and could not re-enter the correct values. Correct values are: Pressure 1009.24, Temperature Air 27.4, Relative Humidity 80.2, Wind direction 270.55, Wind speed 0.59. We will attempt to re-calculate sounding with those values after sounding is completed.
    2019-11-13 22:30 [view ] -11.2097 133.4368 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily checks and file name change
    2019-11-13 23:20 [view ] -11.2083 133.4370 Deployed WeatherBalloon_in2019_v06
    2019-11-14 00:47 [view ] -11.2068 133.4307 SMPS [view] Maintenance AIRBOX_in2019_v06 Orifice blocked (fixed) Poly flow was 0.21, adjusted sheath flow knob until 0.31. This lowered sheath flow to 1.66 (2.42 on classifier). After attempting to correct this (with no success) we found the critical orifice was blocked. We cleaned it and found sheath flow had risen to 2.9. Adjusted excess and sheath flows until all were normal again
    2019-11-14 00:56 [view ] -11.2070 133.4305 Microbiology_in2019_v06
    2019-11-14 02:19 [view ] -11.2087 133.4280 Deployed WeatherBalloon_in2019_v06 02.20 radiosonde initialization failed at first attempt then was corrected at the second attempt. The launching had a delay of 2 minutes.
    2019-11-14 05:21 [view ] -11.2165 133.4245 Deployed WeatherBalloon_in2019_v06 05:15 (UTC) launch
    2019-11-14 06:52 [view ] -11.2175 133.4295 Underway Jack McDonald Hydrochem Lab : TSG46 TSG47 TSG48 Sample TSG_Samples_in2019_v06 TSG04 - 06:57:00 TSG05 - 06:59:00 TSG06 - 07:01:00
    2019-11-14 08:19 [view ] -11.2073 133.4365 Deployed WeatherBalloon_in2019_v06
    2019-11-14 11:20 [view ] -11.2095 133.4428 Deployed WeatherBalloon_in2019_v06 Problem with the Vaisala software. Had to reboot the computer.
    2019-11-14 14:15 [view ] -11.2065 133.4353 Deployed WeatherBalloon_in2019_v06
    2019-11-14 17:17 [view ] -11.2108 133.4375 Deployed WeatherBalloon_in2019_v06 Had to reboot computer as radiosonde was not registering on dock device.
    2019-11-14 20:18 [view ] -11.2047 133.4398 Deployed WeatherBalloon_in2019_v06
    2019-11-14 22:07 [view ] -11.2073 133.4450 Radon Detector [view] Maintenance in2019_v06_Atmospherics Water trap drained small amount of very carbon filled water drained from forward trap. pump turned off briefly to facilitate this
    2019-11-14 22:11 [view ] -11.2073 133.4453 MAAP [view] Change in2019_v06_Atmospherics Bypass flow conditions changed T&RH flow stopped for maintenance on the MFC. Normally 1LPM Bypass flow increased to 8.33 (from 7.33) to compensate, to ensure cutoff remains accurate.
    2019-11-14 22:14 [view ] -11.2073 133.4455 MAAP T&RH Sensor [view] Outage in2019_v06_Atmospherics Flow stopped Flow stopped for MFC 179326 maintenance (swap sensor location from downstream to upstream)
    2019-11-14 23:00 [view ] -11.2073 133.4468 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapped CPCs, QUT sampling
    2019-11-14 23:38 [view ] -11.2073 133.4467 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapped CPCs, QUT sampling
    2019-11-14 23:38 [view ] -11.2073 133.4467 CPC3772 [view] Fault AIRBOX_in2019_v06 Inlet Tubing Cracked (fixed)
    2019-11-14 23:51 [view ] -11.2075 133.4463 MAAP [view] Outage in2019_v06_Atmospherics bypass vacuum disconnected for last 1:40:00 Bypass vacuum was off for previous 1:40:00 (ihr 40mins) due to error with vacuum supply
    2019-11-14 23:54 [view ] -11.2077 133.4462 MAAP [view] Start in2019_v06_Atmospherics MAAP flow conditions restored MAAP flow with bypass and TRH sensors operating normally
    2019-11-14 23:55 [view ] -11.2077 133.4462 MAAP T&RH Sensor [view] Start in2019_v06_Atmospherics Flow back on following MFC maintenance MFC 179326 now has sensor upstream of valve. Pressure sensor monitors sample flow hence volumetric flow measurement is more representative of flow through nafion and sample line
    2019-11-15 00:01 [view ] -11.2078 133.4458 Deployed WeatherBalloon_in2019_v06 Problem with the SPS computer. Had to reboot the box
    2019-11-15 01:17 [view ] -11.2047 133.4457 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken by James H
    2019-11-15 01:34 [view ] -11.2037 133.4462 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken by James H
    2019-11-15 02:16 [view ] -11.2008 133.4465 Deployed WeatherBalloon_in2019_v06
    2019-11-15 04:34 [view ] -11.2042 133.4449 Hydrochem Lab : TSG_Samples_in2019_v06 TSG04 - 06:57:00 TSG05 - 06:59:00 TSG06 - 07:01:00
    2019-11-15 05:27 [view ] -11.2097 133.4432 Deployed WeatherBalloon_in2019_v06 Initial ground calibration failed, laptop and software restarted, successful second calibration. Launch was about 5 minutes late.
    2019-11-15 08:14 [view ] -11.2247 133.4455 Deployed WeatherBalloon_in2019_v06 No problem during calibration
    2019-11-15 11:04 [view ] -11.3510 133.7333 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold
    2019-11-15 11:15 [view ] -11.2060 133.4373 Deployed WeatherBalloon_in2019_v06
    2019-11-15 12:07 [view ] -11.3500 133.7500 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold
    2019-11-15 12:23 [view ] -11.3500 133.7500 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold
    2019-11-15 17:17 [view ] -11.2093 133.4348 Deployed WeatherBalloon_in2019_v06
    2019-11-15 17:40 [view ] -11.2095 133.4352 Aerosol Sample T&RH Sensor Outage in2019_v06_Atmospherics Flow off for MFC maintenance Flow stopped until further notice while I swap the sensor position on the MFC 179324 Parameters before change: - Control: 1.00 LPM Vol Flow - Vol Flow = 1.00 LPM - Mass FLow = 0.71
    2019-11-15 19:05 [view ] -11.2102 133.4375 Aerosol Sample T&RH Sensor Start in2019_v06_Atmospherics Flow restored MFC 179324 modifications complete. The MFC sensors are now upstream of the valve Parameters after change: - Control: 1.00 LPM Vol Flow - Vol Flow = 1.00 LPM - Mass FLow = 0.97 SLPM
    2019-11-15 20:19 [view ] -11.2095 133.4385 Deployed WeatherBalloon_in2019_v06
    2019-11-15 20:20 [view ] -11.2095 133.4387 Aerosol Sample T&RH Sensor Outage in2019_v06_Atmospherics removed MFC to use for MAAP bypass (temporary) Removed MFC 179324
    2019-11-15 20:21 [view ] -11.2095 133.4387 MAAP [view] Change in2019_v06_Atmospherics Bypass MFC swapped for upstream ssensor The MFC for the bypass ( 179327) had a sensor downstream of the valve. Parameters before change: - Control: 7.33 LPM Vol Flow - Vol Flow = 7.33 LPM - Mass FLow = 6.07 SLPM - pressure = 848mBarA I have swapped it for one with the sensor upstream ( 179324), making the measured volumetric flow more representative of VSCC flow (measured at same pressure). Parameters after change: - Control: 7.33 LPM Vol Flow - Vol Flow = 7.33 LPM - Mass FLow = 7.07 SLPM - Pressure = 987 mBarA Better for the VSCC
    2019-11-15 21:29 [view ] -11.2072 133.4427 MAAP [view] Maintenance in2019_v06_Atmospherics Bypass MFC swapped for original MFC, with upstream sensor The MAAP bypass now has its original MFC ( 179327), with upstream sensor. Parameters after change: - Control: 7.33 LPM Vol Flow - Vol Flow = 7.33 LPM - Mass FLow = 7.12 SLPM - Pressure = 993 mBarA
    2019-11-15 21:35 [view ] -11.2070 133.4432 Aerosol Sample T&RH Sensor Start in2019_v06_Atmospherics Flow restarted MFC 179324 reinstalled
    2019-11-15 22:54 [view ] -11.2067 133.4435 Nephelometer [view] Change in2019_v06_Atmospherics MFC swapped for upstream ssensor MFC 179325 removed - has upstream sensor. MFC 179324 installed - has downstream sensor. 179325 will be modifies for downstream sensor and reinstalled shortly. The MFC for the bypass ( 179327) had a sensor downstream of the valve. Parameters before change (upstream sensor): - Control: 5.00 SLPM Mass Flow - Vol Flow = 6.13 LPM - Mass FLow = 5.00 SLPM - pressure = 848mBarA Parameters after change: - Control: 6.00 LPM Vol Flow - Vol Flow = 6.00 LPM - Mass FLow = 5.54 SLPM - Pressure = 951 mBarA
    2019-11-15 23:08 [view ] -11.2067 133.4435 Aerosol Sample T&RH Sensor Outage in2019_v06_Atmospherics Removed MFC to use for Neph line temporarily
    2019-11-15 23:16 [view ] -11.2065 133.4435 Deployed WeatherBalloon_in2019_v06 23:15 (UTC) Launch
    2019-11-15 23:45 [view ] -11.2062 133.4440 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-16 00:11 [view ] -11.2057 133.4437 Nephelometer [view] Maintenance in2019_v06_Atmospherics MFC reinstalled MFC 179325 reinstalled. Parameters after change: - Control: 6.00 LPM Vol Flow - Vol Flow = 6.00 LPM - Mass FLow = 5.64 SLPM - Pressure = 968 mBarA
    2019-11-16 00:14 [view ] -11.2055 133.4437 Aerosol Sample T&RH Sensor Start in2019_v06_Atmospherics MFC reinstalled MFC 179324 reinstalled after being used for neph Parameters after change: - Control: 1.00 LPM Vol Flow - Vol Flow = 1.00 LPM - Mass FLow = 0.97 SLPM - Pressure = 1004 mBarA
    2019-11-16 00:32 [view ] -11.2053 133.4437 CCNC [view] Maintenance in2019_v06_Atmospherics MilliQ filled Zero Check 0.0
    2019-11-16 02:16 [view ] -11.2053 133.4435 Deployed WeatherBalloon_in2019_v06
    2019-11-16 05:25 [view ] -11.2103 133.4402 Deployed WeatherBalloon_in2019_v06 Problem with connection to the SPS box. SPS status lost for more than 20 min. Had to reboot the SPS box.
    2019-11-16 08:15 [view ] -11.2113 133.4380 Deployed WeatherBalloon_in2019_v06
    2019-11-16 09:33 [view ] -11.2112 133.4370 Underway Jack McDonald Hydrochem Lab : TSG49 TSG50 TSG51 Sample TSG_Samples_in2019_v06 Bottle / TSG Sample TSG07 / TSG49 - 09:38 TSG08 / TSG50 - 09:40 TSG09 / TSG51 - 09:42
    2019-11-16 14:14 [view ] -11.2130 133.4348 Deployed WeatherBalloon_in2019_v06
    2019-11-16 17:18 [view ] -11.2053 133.4302 Deployed WeatherBalloon_in2019_v06
    2019-11-16 20:16 [view ] -11.2088 133.4328 Deployed WeatherBalloon_in2019_v06 20:15 (UTC) Launch
    2019-11-16 22:57 [view ] -11.2075 133.4355 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-16 22:57 [view ] -11.2075 133.4355 Aethelometer [view] Restart AIRBOX_in2019_v06 Data Backup Switched off, backed up data to VHTDMA, Switched on
    2019-11-16 23:17 [view ] -11.2078 133.4375 Deployed WeatherBalloon_in2019_v06
    2019-11-16 23:32 [view ] -11.2122 133.4047 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_200.asvp
    2019-11-16 23:34 [view ] -11.2123 133.3998 EM710 [view] Start GSM_in2019_v06 Start pinging/logging Moving 25Nm to WSW of Warruwi Station
    2019-11-16 23:35 [view ] -11.2125 133.3962 SBP [view] Start GSM_in2019_v06 Start logging
    2019-11-17 01:02 [view ] -11.2205 133.1555 SBP [view] Other GSM_in2019_v06 Restarted SBP120 - issues with red thransmitter cards 2-8
    2019-11-17 01:33 [view ] -11.2193 133.0695 SBP [view] Other GSM_in2019_v06 Restart logging
    2019-11-17 01:38 [view ] -11.2175 133.0552 SBP [view] Other GSM_in2019_v06 Restarted SBP120 - issues with red thransmitter cards 1-8
    2019-11-17 01:53 [view ] -11.2213 133.0280 SBP [view] Stop GSM_in2019_v06 At Second station ~25nM west of Warruwi
    2019-11-17 01:54 [view ] -11.2218 133.0283 EM710 [view] Stop GSM_in2019_v06 Stop logging at station 25nM west of Warruwi
    2019-11-17 02:29 [view ] -11.2217 133.0290 Deployed WeatherBalloon_in2019_v06 delayed by 12 minutes
    2019-11-17 04:26 [view ] -11.2235 133.0270 Microbiology_in2019_v06
    2019-11-17 04:26 [view ] -11.2236 133.0270 Microbiology_in2019_v06
    2019-11-17 04:26 [view ] -11.2236 133.0270 Microbiology_in2019_v06
    2019-11-17 05:15 [view ] -11.2252 133.0265 Deployed WeatherBalloon_in2019_v06
    2019-11-17 08:15 [view ] -11.2298 133.0267 Deployed WeatherBalloon_in2019_v06
    2019-11-17 11:18 [view ] -11.2320 133.0298 Deployed WeatherBalloon_in2019_v06
    2019-11-17 14:17 [view ] -11.2315 133.0265 Deployed WeatherBalloon_in2019_v06
    2019-11-17 17:15 [view ] -11.2275 133.0228 Deployed WeatherBalloon_in2019_v06
    2019-11-17 20:18 [view ] -11.2313 133.0265 Deployed WeatherBalloon_in2019_v06
    2019-11-17 22:39 [view ] -11.2275 133.0400 Underway Stephen Tibben Hydrochem Lab : TSG52 Sample TSG_Samples_in2019_v06
    2019-11-17 22:42 [view ] -11.2275 133.0402 Underway Stephen Tibben Hydrochem Lab : TSG53 Sample TSG_Samples_in2019_v06
    2019-11-17 22:43 [view ] -11.2275 133.0403 Underway Stephen Tibben Hydrochem Lab : TSG54 Sample TSG_Samples_in2019_v06
    2019-11-17 23:15 [view ] -11.2285 133.0427 Deployed WeatherBalloon_in2019_v06
    2019-11-18 02:07 [view ] -11.2262 133.0383 Picarro Spectrometer [view] Maintenance in2019_v06_Atmospherics Calibration run started
    2019-11-18 02:10 [view ] -11.2262 133.0380 EM710 [view] Start GSM_in2019_v06 Heading to new station black circle Near Gunns Rock 12 04.5 S 130 55.5E
    2019-11-18 02:11 [view ] -11.2260 133.0380 Deployed WeatherBalloon_in2019_v06
    2019-11-18 02:15 [view ] -11.2205 133.0397 SBP [view] Start GSM_in2019_v06 Heading to new station near Gunns Rock
    2019-11-18 02:55 [view ] -11.1247 133.0945 SBP [view] Other GSM_in2019_v06 Restart logging, power at -10dB
    2019-11-18 02:55 [view ] -11.1247 133.0945 SBP [view] Other GSM_in2019_v06 Restart logging, power at -10dB
    2019-11-18 03:06 [view ] -11.0952 133.1098 SBP [view] Other GSM_in2019_v06 Restart logging, power at -20dB
    2019-11-18 03:22 [view ] -11.0543 133.1132 EM710 [view] Start GSM_in2019_v06 WC start logging C
    2019-11-18 05:16 [view ] -10.8303 132.8573 Deployed WeatherBalloon_in2019_v06
    2019-11-18 06:15 [view ] -10.8292 132.6808 Picarro Spectrometer [view] Maintenance in2019_v06_Atmospherics Stop calibration run and started Monitor run
    2019-11-18 06:55 [view ] -10.8283 132.5598 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_001.asvp Trialing RTOFS and SSM 50m Depth
    2019-11-18 08:16 [view ] -10.8268 132.3300 Deployed WeatherBalloon_in2019_v06
    2019-11-18 11:17 [view ] -10.9690 131.9107 Deployed WeatherBalloon_in2019_v06
    2019-11-18 11:57 [view ] -11.0432 131.8403 POSMV [view] Stop GSM_in2019_v06 Stop USB logging change to new USB C
    2019-11-18 12:01 [view ] -11.0517 131.8323 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_RTOFS_003
    2019-11-18 14:16 [view ] -11.3707 131.6653 Deployed WeatherBalloon_in2019_v06 14:15(UTC) launch
    2019-11-18 15:03 [view ] -11.4897 131.6543 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_xbt_028.asvp XBT drop to 70m. Processed with SSM
    2019-11-18 17:41 [view ] -11.8435 131.5385 Nephelometer [view] Change in2019_v06_Atmospherics Flow rate reduced to 5LPM (Vol) Flow rate reduced from 6LPM to 5 LPM. Sample line humidity was starting to exceed 40% at times
    2019-11-18 17:43 [view ] -11.8445 131.5348 Aerosol Sample T&RH Sensor Change in2019_v06_Atmospherics Flow rate reduced to 0.5LPM (Vol) Sample line humidity was starting to exceed 40% at times. Reduced flow rate in sensor branch from 1.0LPM to 0.5LPM to try to improve conditions Also reduced neph flow from 6 to 5 LPM
    2019-11-18 17:50 [view ] -11.8495 131.5173 MAAP [view] Change in2019_v06_Atmospherics Bypass and TRH branch flows adjusted I have adjusted the flows of the Bypass and TRH sensor branch flows to improve drying efficacy. Conditions before change (all volumetric flows): MAAP flow = 8.33LPM Bypass Flow = 7.33LPM TRH Sensor Flow = 1.0LPM Conditions after change: MAAP Flow = 8.33 LPM Bypass Flow = 7.83 LPM TRH Sensor Flow = 0.50 LPM
    2019-11-18 17:54 [view ] -11.8523 131.5072 MAAP T&RH Sensor [view] Change in2019_v06_Atmospherics Flow rate reduced to 0.5LPM (Vol) Flow rate reduced to try to improve dryer efficacy. See MAAP entry for more details
    2019-11-18 20:15 [view ] -12.0540 131.2115 WeatherBalloon_in2019_v06
    2019-11-18 20:31 [view ] -12.0747 131.1923 SBP [view] Other GSM_in2019_v06 Restart logging
    2019-11-18 22:48 [view ] -12.1645 130.8462 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-18 22:48 [view ] -12.1650 130.8455 CPC3772 [view] Change AIRBOX_in2019_v06 Swapping CPCs CSIRO sampling
    2019-11-18 23:15 [view ] -12.1832 130.8063 WeatherBalloon_in2019_v06
    2019-11-19 00:13 [view ] -12.1205 130.6787 Air Chem Lab [view] Change in2019_v06_Atmospherics Lab Air Con Temp increased to 27 Outside dew point exceeds 25C. RH in Air Chem manifold is 95% and increasing. Lab temp increased to try to increase manifold temp and prevent droplets from forming
    2019-11-19 00:45 [view ] -12.0945 130.6263 EM710 [view] Stop GSM_in2019_v06 Stop logging at station 3 Near Gunns Rock
    2019-11-19 00:47 [view ] -12.0945 130.6263 SBP [view] Stop GSM_in2019_v06 Stop logging Stn 3
    2019-11-19 02:26 [view ] -12.0935 130.6258 Deployed WeatherBalloon_in2019_v06 10 minutes late start - balloon burst!
    2019-11-19 05:14 [view ] -12.0847 130.6127 Deployed WeatherBalloon_in2019_v06
    2019-11-19 05:56 [view ] -12.0815 130.6067 Seapath [view] Outage GSM_in2019_v06 Noticed Seapath Not recieving any RTCM signals
    2019-11-19 05:57 [view ] -12.0818 130.6068 EM710 [view] Start GSM_in2019_v06 Logging return to Station ~2nm
    2019-11-19 06:45 [view ] -12.4333 131.7000 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold. Going past Gunn Point
    2019-11-19 07:04 [view ] -12.4833 131.6500 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold. Going past Gunn Point
    2019-11-19 08:15 [view ] -12.1003 130.6300 Deployed WeatherBalloon_in2019_v06
    2019-11-19 11:15 [view ] -12.1005 130.6342 Deployed WeatherBalloon_in2019_v06
    2019-11-19 12:27 [view ] -12.1002 130.6343 EM710 [view] Other GSM_in2019_v06 New SVP Applied in2019_v06_ctd_203.asvp SVP applied, sounder not pinging. On station
    2019-11-19 14:16 [view ] -12.1000 130.6345 Deployed WeatherBalloon_in2019_v06
    2019-11-19 17:10 [view ] -12.0995 130.6345 Deployed WeatherBalloon_in2019_v06
    2019-11-19 20:15 [view ] -12.0965 130.6338 Deployed WeatherBalloon_in2019_v06
    2019-11-19 22:58 [view ] -12.0968 130.6398 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-19 23:15 [view ] -12.0967 130.6398 Deployed WeatherBalloon_in2019_v06
    2019-11-20 02:16 [view ] -12.0960 130.6400 Deployed WeatherBalloon_in2019_v06
    2019-11-20 03:43 [view ] -12.0930 130.6395 Aerosol Lab [view] Change in2019_v06_Atmospherics changes to air flow I have applied some makeshift
    2019-11-20 05:15 [view ] -12.0843 130.6370 Deployed WeatherBalloon_in2019_v06
    2019-11-20 06:01 [view ] -12.0937 130.6280 EM710 [view] Start GSM_in2019_v06 Log return to station waypoint
    2019-11-20 08:16 [view ] -12.0918 130.6212 Deployed WeatherBalloon_in2019_v06 08:15 UTC Launch
    2019-11-20 09:05 [view ] -12.0962 130.6252 EM710 [view] Start GSM_in2019_v06 Start logging Repositioning ship
    2019-11-20 11:11 [view ] -12.2935 130.4328 EM710 [view] Stop GSM_in2019_v06 Stop logging at new station.
    2019-11-20 11:18 [view ] -12.2955 130.4318 Deployed WeatherBalloon_in2019_v06
    2019-11-20 11:26 [view ] -12.3003 130.4240 EM710 [view] SVP GSM_in2019_v06 New SVP in2019_v06_RTOFS_004.asvp
    2019-11-20 11:26 [view ] -12.3012 130.4233 EM710 [view] Start GSM_in2019_v06 Vessel underway logging on
    2019-11-20 14:15 [view ] -12.3170 130.4040 Deployed WeatherBalloon_in2019_v06
    2019-11-20 17:15 [view ] -12.3193 130.4038 Deployed WeatherBalloon_in2019_v06
    2019-11-20 20:15 [view ] -12.3198 130.4027 Deployed WeatherBalloon_in2019_v06
    2019-11-20 21:04 [view ] -12.3188 130.4043 EM710 [view] Start GSM_in2019_v06 drifting
    2019-11-20 21:09 [view ] -12.3188 130.4043 EM710 [view] Stop GSM_in2019_v06 Thought we were moving, but not
    2019-11-20 23:20 [view ] -12.3175 130.4048 Deployed WeatherBalloon_in2019_v06
    2019-11-21 02:16 [view ] -12.3167 130.4048 WeatherBalloon_in2019_v06
    2019-11-21 02:55 [view ] -12.3165 130.4048 Underway Stephen Tibben Hydrochem Lab : TSG55 Sample TSG_Samples_in2019_v06
    2019-11-21 02:56 [view ] -12.3165 130.4048 Underway Stephen Tibben Hydrochem Lab : TSG56 Sample TSG_Samples_in2019_v06
    2019-11-21 02:59 [view ] -12.3165 130.4048 Underway Stephen Tibben Hydrochem Lab : TSG57 Sample TSG_Samples_in2019_v06
    2019-11-21 04:19 [view ] -12.3160 130.4048 All Observation AIRBOX_in2019_v06 Needle gun work in nearby pump locker Needle gun work in nearby pump locker commenced at 1215 ship time - 0245UTC
    2019-11-21 04:33 [view ] -12.3153 130.4048 All Observation AIRBOX_in2019_v06 Needle gun work stopped Needle gun work in nearby pump locker has stopped. Apparently there was also some painting.
    2019-11-21 05:16 [view ] -12.3145 130.4048 Deployed WeatherBalloon_in2019_v06
    2019-11-21 07:00 [view ] -12.3148 130.4050 AIRBOX_in2019_v06 Grinding near Airbox - possible influence on instrument measurements I was told this evening there was grinding near the AIRBOX which may have affected our measurements. I was told it was "around lunch time" but haven& 39;t been given an exact start/finish time.
    2019-11-21 08:16 [view ] -12.3150 130.4052 Deployed WeatherBalloon_in2019_v06
    2019-11-21 09:17 [view ] -12.3165 130.4052 CPC3772 [view] Observation AIRBOX_in2019_v06 Large particle increases Noticed large particle jumps (~10,000 - ~25,000, up from ~900) around 13:35 local time today (4:05 UTC). This is likely from the grinding mentioned earlier. Spikes last ~2-3 mins before returning to normal levels.
    2019-11-21 11:16 [view ] -12.3167 130.4052 Deployed WeatherBalloon_in2019_v06
    2019-11-21 14:15 [view ] -12.3177 130.4050 Deployed WeatherBalloon_in2019_v06
    2019-11-21 17:16 [view ] -12.3155 130.4063 WeatherBalloon_in2019_v06
    2019-11-21 20:19 [view ] -12.3183 130.4058 Deployed WeatherBalloon_in2019_v06
    2019-11-21 22:46 [view ] -12.3205 130.3985 Observation AIRBOX_in2019_v06 Bushire burning Rob said there was signs of bushfire smoke on the Spectronus last night/early this morning (Current time is 8:15 local time, so "last night/early this morning" would be ~16:00 - 20:00 UTC). It would be worth checking our data and Changda& 39;s filters from this period
    2019-11-21 22:48 [view ] -12.3205 130.3985 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-21 23:05 [view ] -12.3207 130.3988 Stabilised Platform Maintenance in2019_v06_Atmospherics Testing profiler
    2019-11-21 23:16 [view ] -12.3208 130.3993 WeatherBalloon_in2019_v06
    2019-11-22 00:08 [view ] -12.3218 130.4037 Stabilised Platform Start in2019_v06_Atmospherics restarted normal tracking
    2019-11-22 01:29 [view ] -12.3208 130.4063 Stabilised Platform Stop in2019_v06_Atmospherics Stopped to test new profiling mode
    2019-11-22 01:59 [view ] -12.3203 130.4068 Stabilised Platform Start in2019_v06_Atmospherics running profiler
    2019-11-22 02:16 [view ] -12.3200 130.4073 Deployed WeatherBalloon_in2019_v06 02:15 (UTC) Launch
    2019-11-22 04:41 [view ] -12.3145 130.4115 Stabilised Platform Change in2019_v06_Atmospherics reduced max speed to 6.0 reduced from 8.0 to 6.0 to minimise overshoot.
    2019-11-22 05:08 [view ] -12.3125 130.4125 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_rctd_001.asvp Testing Training Rapidcast Winch and RapidCTD while stationary
    2019-11-22 05:15 [view ] -12.3118 130.4128 Deployed WeatherBalloon_in2019_v06
    2019-11-22 08:15 [view ] -12.3182 130.4028 Deployed WeatherBalloon_in2019_v06
    2019-11-22 11:15 [view ] -12.3205 130.4027 Deployed WeatherBalloon_in2019_v06
    2019-11-22 11:43 [view ] -12.3205 130.4027 POSMV [view] Other GSM_in2019_v06 Stop/start USB logging
    2019-11-22 14:15 [view ] -12.3183 130.4033 WeatherBalloon_in2019_v06 Slow inflation speed with new helium tanks...
    2019-11-22 17:16 [view ] -12.3157 130.4035 Deployed WeatherBalloon_in2019_v06
    2019-11-22 20:20 [view ] -12.3113 130.3998 Deployed WeatherBalloon_in2019_v06 launching time 05.48 am due to heavy rain.
    2019-11-22 21:09 [view ] -12.3070 130.3990 CPC 3772 [view] Change in2019_v06_Atmospherics MFC pressure set to mBarA. Was PSIg
    2019-11-22 22:21 [view ] -12.3100 130.4012 CPC 3772 [view] Maintenance in2019_v06_Atmospherics restarted code. can't see summary data on network
    2019-11-22 22:33 [view ] -12.3100 130.4010 Aethelometer [view] Restart AIRBOX_in2019_v06 Turned off, downloaded data, turned on
    2019-11-22 22:33 [view ] -12.3100 130.4010 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapped CPCs, QUT sampling
    2019-11-22 22:34 [view ] -12.3100 130.4010 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-22 23:00 [view ] -12.3105 130.4007 Stabilised Platform Stop in2019_v06_Atmospherics stopped 5 point profile to test new profiles
    2019-11-22 23:15 [view ] -12.3107 130.4007 Deployed WeatherBalloon_in2019_v06
    2019-11-22 23:44 [view ] -12.3112 130.4003 Stabilised Platform Start in2019_v06_Atmospherics Testing complete. Restarted 5 point profiler
    2019-11-23 00:41 [view ] -12.3125 130.4000 Radon [view] AIRBOX_in2019_v06 Calibration and background details - 20/11/19 23:37: Ext and int flow cables unplugged (Manual background procedure started) - 22/11/19 00:02: Ext and int flow cables replugged (Manual background ended), pump switch turned on, starting manual calibration procedure 22/11/19 09:06: Valve switch turned on, continuing manual calibration procedure 22/11/19 23:09: Valve and pump switches off, ending manual calibration procedure - Following these, external flow has dropped to around 0-2 L/min, about 3 hrs before manual calib was stopped. Ext flow recovered successfully after manual background, but seems to have failed now.
    2019-11-23 02:16 [view ] -12.3142 130.4043 Deployed WeatherBalloon_in2019_v06
    2019-11-23 02:53 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:03 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres) N.B. For Duration of RapidCastProTime series, EM710 is turned on every time for pinging depth and retrieving NMEA Lat/Long to RapidCast Winch (no sounder logging activated)
    2019-11-23 03:05 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:08 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06  RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:09 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06   RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:09 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:10 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:10 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:11 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:11 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:29 [view ] -12.3138 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 03:57 [view ] -12.3140 130.4047 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series RapidCastPro Time Series - Every 30min starting 08:00 (down to 5 metres)
    2019-11-23 04:29 [view ] -12.3133 130.4048 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series Duplicate Found the Salinity <1m to be low (~30) at 13:30 drop. Re-tested with slower drop rate, resulted in significantly different reading (<0m) of ~35. Re-adjusted method for time series drop to leave the RapidCastPro CTDF just below the water surface and change lower trigger to 0.5m (from 0.05m). Craig had to put bluetooth box on top as it was not connecting to unit at surface water depth. It seems ok now. Recommendations - take all data readings for (first 1m) with low confidence. 14:00 series onwards should be more reliable.
    2019-11-23 04:42 [view ] -12.3130 130.4050 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series
    2019-11-23 04:58 [view ] -12.3128 130.4050 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series
    2019-11-23 05:00 [view ] -12.3128 130.4050 Rapid Cast [view] Stop GSM_in2019_v06 RapidCastPro Time Series Stopped to recharge battery.
    2019-11-23 05:02 [view ] -12.3128 130.4050 NAIS [view] Stop AIRBOX_in2019_v06 Unknown shutdown Noticed the NAIS was shutdown. Not sure of the cause, lapop possibly reboot. Need instructions on how to restart Restart by loading config file (most recent one, last edited in November), then just hit Run (Software is Spectrops)
    2019-11-23 05:17 [view ] -12.3128 130.4050 Deployed WeatherBalloon_in2019_v06 Inflation time longer due to new Helium bottles.
    2019-11-23 05:23 [view ] -12.3128 130.4050 Aethelometer [view] Fault AIRBOX_in2019_v06 Data not logging Data wasnt logging. Memory card wasnt in properly. Fixed.
    2019-11-23 08:15 [view ] -12.3170 130.4048 Deployed WeatherBalloon_in2019_v06 Old elog not submitted by previous team - Ewan
    2019-11-23 08:31 [view ] -12.3165 130.4052 Rapid Cast [view] Start GSM_in2019_v06 Profile to 5m Time Series 2. Battery Voltage = 39.77
    2019-11-23 09:00 [view ] -12.3153 130.4055 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series II
    2019-11-23 11:17 [view ] -12.3160 130.4053 Deployed WeatherBalloon_in2019_v06
    2019-11-23 12:42 [view ] -12.3162 130.4018 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_ctd_234.asvp
    2019-11-23 13:30 [view ] -12.3187 130.4025 Rapid Cast [view] RapidCTD GSM_in2019_v06 Continue time series 2 30min to 5m
    2019-11-23 14:22 [view ] -12.3192 130.4037 Deployed WeatherBalloon_in2019_v06
    2019-11-23 17:16 [view ] -12.3138 130.4095 WeatherBalloon_in2019_v06
    2019-11-23 17:32 [view ] -12.3133 130.4097 Rapid Cast [view] Stop GSM_in2019_v06 RapidCastPro Time Series Stopped to recharge battery.
    2019-11-23 17:32 [view ] -12.3133 130.4097 Rapid Cast [view] Start GSM_in2019_v06 RapidCastPro Time Series Started after battery recharge.
    2019-11-23 20:15 [view ] -12.3062 130.3998 Deployed WeatherBalloon_in2019_v06 20:15 (UTC) Launch
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III Test run after battery charge. Start Time Series from 21:00 UTC
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III Appears time series at 00:00 UTC will not download. Perhaps corrupt file? Hence 00:15 UTC extra time series data.
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III TEST run mode = slow (better result)
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III TEST run mode = fast
    2019-11-23 20:49 [view ] -12.3067 130.3990 Rapid Cast [view] Drop GSM_in2019_v06 RapidCastPro Time Series III
    2019-11-23 23:16 [view ] -12.3103 130.3942 Deployed WeatherBalloon_in2019_v06
    2019-11-23 23:47 [view ] -12.3113 130.3937 Underway Stephen Tibben Hydrochem Lab : TSG58 Sample TSG_Samples_in2019_v06
    2019-11-23 23:50 [view ] -12.3113 130.3937 Underway Stephen Tibben Hydrochem Lab : TSG59 Sample TSG_Samples_in2019_v06
    2019-11-23 23:52 [view ] -12.3113 130.3937 Underway Stephen Tibben Hydrochem Lab : TSG60 Sample TSG_Samples_in2019_v06
    2019-11-24 01:15 [view ] -12.3130 130.3933 Deployed WeatherBalloon_in2019_v06 special sonde for cloud radar validation
    2019-11-24 02:22 [view ] -12.3152 130.3973 Deployed WeatherBalloon_in2019_v06 Special launch for cloud radar validation
    2019-11-24 05:04 [view ] -12.3162 130.3985 Rapid Cast [view] Stop GSM_in2019_v06 Rapidcast Time Series halted for probe recharge. Last Cast 04:30
    2019-11-24 05:15 [view ] -12.3160 130.3985 Deployed WeatherBalloon_in2019_v06 Back to 3 hourly
    2019-11-24 07:05 [view ] -12.3140 130.3987 Rapid Cast [view] RapidCTD GSM_in2019_v06 Start Continous recording at ~1m for 5min.
    2019-11-24 08:15 [view ] -12.3125 130.3985 Deployed WeatherBalloon_in2019_v06
    2019-11-24 10:14 [view ] -11.2112 133.4395 SBP [view] File GSM_in2019_v06 Continue logging SBP120 - mapping
    2019-11-24 11:17 [view ] -12.3033 130.3945 Deployed WeatherBalloon_in2019_v06
    2019-11-24 12:30 [view ] -12.3038 130.3918 Rapid Cast [view] RapidCTD GSM_in2019_v06 Time series No 4 Cast 015
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series IV
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series IV
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series IV Start 5m Time Series (every 30min)
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 Casting to 30m while CTD getting repaired.
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series IV END End of RapidCastPro CTD Time Series @21:30 UTC & CTD (25m cast)
    2019-11-24 14:00 [view ] -12.3035 130.3920 Rapid Cast [view] RapidCTD GSM_in2019_v06 RapidCastPro Time Series IV
    2019-11-24 14:16 [view ] -12.3032 130.3920 Deployed WeatherBalloon_in2019_v06
    2019-11-24 15:53 [view ] -12.3040 130.3932 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_rctd_002.asvp
    2019-11-24 17:15 [view ] -12.3025 130.3935 Deployed WeatherBalloon_in2019_v06
    2019-11-24 20:16 [view ] -12.2968 130.3932 Deployed WeatherBalloon_in2019_v06
    2019-11-24 22:37 [view ] -12.2915 130.3877 CPC3772 [view] Observation AIRBOX_in2019_v06 Changed sample line CPC was getting much higher counts than SMPS, by order of magnitude. Noticed sample line was cracked. Changed sample line and the two are in closer agreement again.
    2019-11-24 22:39 [view ] -12.3040 130.3932 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_rctd_003.asvp
    2019-11-24 22:39 [view ] -12.3040 130.3932 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_rctd_004.asvp
    2019-11-24 22:51 [view ] -12.2932 130.3867 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-24 23:12 [view ] -12.2938 130.3848 EM710 [view] Start GSM_in2019_v06 Heading Bearing 276, 20Nm Requested bearing of 276 to capture new bathymetry in between historical lines.
    2019-11-24 23:12 [view ] -12.2938 130.3848 EM710 [view] Start GSM_in2019_v06 Heading Bearing 276, 20Nm
    2019-11-24 23:12 [view ] -12.2938 130.3848 EM710 [view] Stop GSM_in2019_v06 Heading Bearing 276, 20Nm Short stop for CTD
    2019-11-24 23:14 [view ] -12.2942 130.3842 SBP [view] Start GSM_in2019_v06 Started logging SBP120 - mapping
    2019-11-24 23:14 [view ] -12.2942 130.3842 SBP [view] Start GSM_in2019_v06 Continue logging SBP120 - mapping
    2019-11-24 23:14 [view ] -12.2942 130.3842 SBP [view] Stop GSM_in2019_v06 Continue logging SBP120 - mapping At short stop for CTD
    2019-11-24 23:14 [view ] -12.2942 130.3842 SBP [view] File GSM_in2019_v06 Continue logging SBP120 - mapping
    2019-11-24 23:15 [view ] -12.2943 130.3838 Deployed WeatherBalloon_in2019_v06
    2019-11-25 02:15 [view ] -12.2547 129.9830 Deployed WeatherBalloon_in2019_v06
    2019-11-25 03:31 [view ] -12.2607 130.0863 NAIS [view] Start AIRBOX_in2019_v06 Restarted After unknown shutdown
    2019-11-25 05:07 [view ] -12.2922 130.3585 SBP [view] Stop GSM_in2019_v06 Stopped on Station
    2019-11-25 05:08 [view ] -12.2925 130.3585 EM710 [view] Start GSM_in2019_v06 Stopped at Station
    2019-11-25 05:15 [view ] -12.2942 130.3603 Deployed WeatherBalloon_in2019_v06
    2019-11-25 05:20 [view ] -12.2968 130.3635 EM710 [view] Start GSM_in2019_v06 Underway again??
    2019-11-25 08:17 [view ] -12.2938 130.3940 Deployed WeatherBalloon_in2019_v06
    2019-11-25 11:18 [view ] -12.2945 130.3905 Deployed WeatherBalloon_in2019_v06
    2019-11-25 14:16 [view ] -12.3147 130.4020 Deployed WeatherBalloon_in2019_v06 14:15(UTC) launch
    2019-11-25 17:16 [view ] -12.3092 130.4103 Deployed WeatherBalloon_in2019_v06
    2019-11-25 20:18 [view ] -12.3073 130.4132 Deployed WeatherBalloon_in2019_v06
    2019-11-25 22:21 [view ] -12.3098 130.4128 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-25 23:16 [view ] -12.3097 130.4127 Deployed WeatherBalloon_in2019_v06
    2019-11-26 02:16 [view ] -12.3103 130.4028 WeatherBalloon_in2019_v06
    2019-11-26 05:15 [view ] -12.3147 130.4092 CCNC [view] Change in2019_v06_Atmospherics Logged in remotely to change SS sequence Time: 26/11/2019 05:15 Ruhi Subject – Logged in remotely to change SS sequence Comments: Logged in remotely – instrument struggling with the remote connection and flows may be affected by CPU loading. Stopped measurement and closed software. Edited Table 1 of the SS sequence to reverse the order. Previous order was an hourly cycle of 6 SS, 10 min each 0.2, 0.3, 0.4, 0.5, 0.6, 1.0 New order is the reverse (10 min at each still): 1.0, 0.6, 0.5, 0.4, 0.3, 0.2. I have done this to try to improve the OPC temperature adherence – during the previous cycle, the transition from 1.0 to 0.2% doesn’t provide enough time for the OPC temperature to reach setpoint, creating a condition where the droplets may be evaporating in the OPC before detection. I have been advised that this may be improved by reversing the sequence (or doing a pyramid sequence, which is not ideal).
    2019-11-26 05:15 [view ] -12.3147 130.4092 Deployed WeatherBalloon_in2019_v06
    2019-11-26 07:12 [view ] -12.3100 130.4108 EM710 [view] Start GSM_in2019_v06 Underway mapping transit to Warruwi waypoint
    2019-11-26 07:26 [view ] -12.2885 130.4408 SBP [view] Start GSM_in2019_v06 Start logging SBP for transit
    2019-11-26 08:16 [view ] -12.2293 130.5588 Deployed WeatherBalloon_in2019_v06
    2019-11-26 08:37 [view ] -12.2207 130.6170 EM710 [view] Other GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_005.asvp RTOFS Profile from SSM modified to match TSS
    2019-11-26 09:51 [view ] -12.1518 130.8583 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold G050-Y27 Going past Gunn Point
    2019-11-26 09:55 [view ] -12.1425 130.8672 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_006.asvp
    2019-11-26 10:04 [view ] -12.1182 130.8902 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold G050-Y28 Sample taken going past Gunn Point.
    2019-11-26 10:21 [view ] -12.0757 130.9307 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_007.asvp Modified profile to match TSS
    2019-11-26 11:16 [view ] -12.0927 131.1270 Deployed WeatherBalloon_in2019_v06
    2019-11-26 14:16 [view ] -11.8365 131.5545 Deployed WeatherBalloon_in2019_v06
    2019-11-26 16:11 [view ] -11.5370 131.6558 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_009.asvp Modified from TSS
    2019-11-26 16:56 [view ] -11.4255 131.6678 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_xbt_029.asvp
    2019-11-26 16:56 [view ] -11.4255 131.6678 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_xbt_edit_031.asvp Edited previous xbt template and adjusted using SST and trend (in lack of xbt data in marine park).
    2019-11-26 16:56 [view ] -11.4255 131.6678 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_xbt_030.asvp
    2019-11-26 17:16 [view ] -11.3812 131.6780 Deployed WeatherBalloon_in2019_v06
    2019-11-26 18:17 [view ] -11.2605 131.6808 SBP [view] Start GSM_in2019_v06 Started logging SBP120 - restart after went glitchy
    2019-11-26 20:15 [view ] -11.0653 131.8242 Deployed WeatherBalloon_in2019_v06
    2019-11-26 23:04 [view ] -10.8298 132.1785 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-26 23:05 [view ] -10.8298 132.1792 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapping CPCs CSIRO sampling
    2019-11-26 23:05 [view ] -10.8298 132.1797 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Added Butonal to both CPCs
    2019-11-26 23:18 [view ] -10.8298 132.2137 WeatherBalloon_in2019_v06
    2019-11-27 02:16 [view ] -10.8323 132.6498 Deployed WeatherBalloon_in2019_v06
    2019-11-27 04:37 [view ] -10.9067 132.9552 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_sst_038.asvp
    2019-11-27 05:16 [view ] -10.9767 133.0282 Deployed WeatherBalloon_in2019_v06
    2019-11-27 05:50 [view ] -11.0423 133.0947 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_010.asvp C
    2019-11-27 07:10 [view ] -11.2193 133.0472 EM710 [view] Stop GSM_in2019_v06 Stop logging on station for CTD C
    2019-11-27 07:12 [view ] -11.2193 133.0473 SBP [view] Stop GSM_in2019_v06
    2019-11-27 07:18 [view ] -11.2195 133.0472 Microbiology_in2019_v06
    2019-11-27 08:15 [view ] -11.2190 133.0478 Deployed WeatherBalloon_in2019_v06 08:15 UTC Launch
    2019-11-27 11:20 [view ] -11.2178 133.0492 Deployed WeatherBalloon_in2019_v06 11:18 UTC Launch
    2019-11-27 13:03 [view ] -11.2192 133.0482 POSMV [view] new usb GSM_in2019_v06 change over usb
    2019-11-27 14:15 [view ] -11.2203 133.0472 Deployed WeatherBalloon_in2019_v06
    2019-11-27 16:30 [view ] -11.2202 133.0473 Microbiology_in2019_v06
    2019-11-27 16:40 [view ] -11.2197 133.0478 Underway Stephen Tibben Hydrochem Lab : TSG61 Sample TSG_Samples_in2019_v06
    2019-11-27 16:42 [view ] -11.2195 133.0480 Underway Stephen Tibben Hydrochem Lab : TSG62 Sample TSG_Samples_in2019_v06
    2019-11-27 16:43 [view ] -11.2195 133.0480 Underway Stephen Tibben Hydrochem Lab : TSG63 Sample TSG_Samples_in2019_v06
    2019-11-27 17:15 [view ] -11.2182 133.0490 Deployed WeatherBalloon_in2019_v06
    2019-11-27 20:16 [view ] -11.2162 133.0500 Deployed WeatherBalloon_in2019_v06
    2019-11-27 23:15 [view ] -11.2127 133.0513 Deployed WeatherBalloon_in2019_v06
    2019-11-28 01:30 [view ] -11.2115 133.0428 Microbiology_in2019_v06
    2019-11-28 02:16 [view ] -11.2082 133.0465 Deployed WeatherBalloon_in2019_v06
    2019-11-28 02:26 [view ] -11.1930 133.0590 EM710 [view] SVP GSM_in2019_v06 Add new rCTD from file 276 - 2am UTC
    2019-11-28 02:28 [view ] -11.1903 133.0603 EM710 [view] Start GSM_in2019_v06 Start loggin EM710 line 0206
    2019-11-28 02:28 [view ] -11.1887 133.0610 SBP [view] Start GSM_in2019_v06 Start logging Line 030 segy Heading over object at 11 07.67S, 133 05.36 E
    2019-11-28 05:09 [view ] -10.8445 132.8967 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_011.asvp Created using TSS
    2019-11-28 05:15 [view ] -10.8332 132.8838 Deployed WeatherBalloon_in2019_v06
    2019-11-28 08:16 [view ] -10.8250 132.3970 Deployed WeatherBalloon_in2019_v06
    2019-11-28 08:47 [view ] -10.8243 132.3137 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_012.asvp Modified for TSS
    2019-11-28 11:16 [view ] -10.9142 131.9557 Deployed WeatherBalloon_in2019_v06
    2019-11-28 11:38 [view ] -10.9550 131.9158 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_013.asvp Modified using TSS
    2019-11-28 12:46 [view ] -11.0798 131.7998 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_014.asvp Synthetic profile derived from RTOFS_013.
    2019-11-28 13:39 [view ] -11.1645 131.7203 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_016.asvp Synthetic profile using TSS
    2019-11-28 14:16 [view ] -11.2192 131.6790 Deployed WeatherBalloon_in2019_v06
    2019-11-28 15:29 [view ] -11.3432 131.6652 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_017.asvp Modified for TSS
    2019-11-28 16:28 [view ] -11.4645 131.6558 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_xbt_031.asvp
    2019-11-28 17:17 [view ] -11.5818 131.6467 Deployed WeatherBalloon_in2019_v06 Ship still travelling with some small speed when balloon launched.
    2019-11-28 20:17 [view ] -11.9185 131.3367 Deployed WeatherBalloon_in2019_v06
    2019-11-28 23:16 [view ] -12.0797 131.0480 Deployed WeatherBalloon_in2019_v06
    2019-11-29 00:49 [view ] -12.0780 130.9052 EM710 [view] Stop GSM_in2019_v06 At Waypoint station near Gunns Rock
    2019-11-29 00:52 [view ] -12.0778 130.9050 SBP [view] Stop GSM_in2019_v06 At station waypoint near Gunns Rock
    2019-11-29 02:15 [view ] -12.0795 130.9005 Deployed WeatherBalloon_in2019_v06 02:15 UTC Launch
    2019-11-29 03:28 [view ] -12.0797 130.9007 CPC3772 [view] Observation AIRBOX_in2019_v06 High counts Very high counts on the CPC. Before checking this, we noticed a weird smell, like burning plastic. The high CPC counts are possibly from burning trash on the ship
    2019-11-29 03:29 [view ] -12.0797 130.9006 Oxygen Analyser [view] Outage in2019_v06_Atmospherics pc restarted - com port locked
    2019-11-29 05:17 [view ] -12.0785 130.9000 Deployed WeatherBalloon_in2019_v06
    2019-11-29 08:16 [view ] -12.0800 130.9022 Deployed WeatherBalloon_in2019_v06
    2019-11-29 11:15 [view ] -12.0797 130.9022 Deployed WeatherBalloon_in2019_v06
    2019-11-29 14:15 [view ] -12.0818 130.9023 Deployed WeatherBalloon_in2019_v06
    2019-11-29 14:30 [view ] -12.0832 130.9015 EM710 [view] Start GSM_in2019_v06 Underway to Berrimah Site
    2019-11-29 14:52 [view ] -12.1217 130.8625 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_ctd_297_modifed.asvp CTD 297 modified for TSS
    2019-11-29 14:55 [view ] -12.1287 130.8573 SBP [view] Start GSM_in2019_v06
    2019-11-29 17:16 [view ] -12.2552 130.4870 Deployed WeatherBalloon_in2019_v06
    2019-11-29 18:02 [view ] -12.3118 130.4107 EM710 [view] Stop GSM_in2019_v06 Stopped logging EM710 & SBP - Stationary
    2019-11-29 18:03 [view ] -12.3118 130.4107 SBP [view] Stop GSM_in2019_v06 Stopped logging EM710 & SBP - Stationary
    2019-11-29 20:16 [view ] -12.3107 130.4113 Deployed WeatherBalloon_in2019_v06
    2019-11-29 22:37 [view ] -12.3107 130.4113 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-29 23:15 [view ] -12.3107 130.4113 Deployed WeatherBalloon_in2019_v06
    2019-11-30 02:16 [view ] -12.3060 130.4057 Deployed WeatherBalloon_in2019_v06
    2019-11-30 05:20 [view ] -12.3095 130.4020 Deployed WeatherBalloon_in2019_v06
    2019-11-30 08:16 [view ] -12.3133 130.4030 Deployed WeatherBalloon_in2019_v06 Special twin launch
    2019-11-30 09:10 [view ] -12.3127 130.4110 EK60 [view] Start GSM_in2019_v06 Start pinging to test ranger USBL
    2019-11-30 11:17 [view ] -12.3105 130.4097 WeatherBalloon_in2019_v06
    2019-11-30 14:13 [view ] -12.3115 130.4095 Deployed WeatherBalloon_in2019_v06
    2019-11-30 17:16 [view ] -12.3143 130.4058 Deployed WeatherBalloon_in2019_v06
    2019-11-30 20:16 [view ] -12.3133 130.4068 Deployed WeatherBalloon_in2019_v06 20:15 (UTC) Launch
    2019-11-30 23:12 [view ] -12.3138 130.4068 CPC3772 [view] Fault AIRBOX_in2019_v06 QUT CPC aerosol flow error Swapped CPCs to QUT CPC. Aerosol flow error on software. Zero counts. Zero flow with gilibrator.
    2019-11-30 23:12 [view ] -12.3138 130.4068 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-11-30 23:15 [view ] -12.3138 130.4068 CPC3772 [view] Observation AIRBOX_in2019_v06 Butanol leak from dryer Moved dryer from QUT CPC to CSIRO CPC this morning as part of normal maintenance routine. The tubing connected to the bottom of the dryer became caught on something and was pulled out, resulting in a small (~1 mL or less) butanol leak on the bench. Leak cleaned up using chemical cleaning pads in the AIRBOX, and door was held open for 10-20 minutes to allow fumes to vent out. Incident reported to voyage manager
    2019-11-30 23:16 [view ] -12.3138 130.4068 Deployed WeatherBalloon_in2019_v06
    2019-12-01 02:18 [view ] -12.3132 130.4045 Deployed WeatherBalloon_in2019_v06
    2019-12-01 03:00 [view ] -12.3127 130.4042 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Disconnected from sample line Disconnected CPC from sample line for maintenance. Sample line was not immediately blocked so there may have been some samples taken from lab air
    2019-12-01 04:55 [view ] -12.3127 130.4042 CPC3772 [view] Start AIRBOX_in2019_v06 Restarted After Cleaning/Swapped CPCs Cleaned orifice inside CPC. Swapped CPCs this morning. QUT sampling (QUT had the orifice cleaned)
    2019-12-01 05:15 [view ] -12.3125 130.4042 Deployed WeatherBalloon_in2019_v06 Caradi special
    2019-12-01 05:37 [view ] -12.3125 130.4042 POSMV [view] Start GSM_in2019_v06 Restart Ethernet logging Ethernet logging was not on. Restarted. Vessel Stationary (not logging MB data). Estimated off for 12 hours
    2019-12-01 08:16 [view ] -12.3152 130.4060 Deployed WeatherBalloon_in2019_v06
    2019-12-01 11:57 [view ] -12.3143 130.4062 Deployed WeatherBalloon_in2019_v06
    2019-12-01 14:16 [view ] -12.3123 130.4042 Deployed WeatherBalloon_in2019_v06
    2019-12-01 17:15 [view ] -12.3098 130.4115 Deployed WeatherBalloon_in2019_v06
    2019-12-01 20:15 [view ] -12.3093 130.4155 Deployed WeatherBalloon_in2019_v06
    2019-12-01 23:17 [view ] -12.3105 130.4122 Deployed WeatherBalloon_in2019_v06
    2019-12-02 01:12 [view ] -12.3103 130.4103 Picarro Spectrometer [view] Change in2019_v06_Atmospherics Disconnect Picarro chiller for comparison with Spectronus data -Disconnect Picarro chiller for comparison with Spectronus data Reconnected chiller 8:19am-8:20am UTC. (17:49-18:00 Local) 2/12/19
    2019-12-02 02:19 [view ] -12.3107 130.4100 Deployed WeatherBalloon_in2019_v06
    2019-12-02 05:16 [view ] -12.3133 130.4100 Deployed WeatherBalloon_in2019_v06
    2019-12-02 07:02 [view ] -12.3173 130.4103 WeatherBalloon_in2019_v06
    2019-12-02 08:22 [view ] -12.3152 130.4123 Deployed WeatherBalloon_in2019_v06
    2019-12-02 11:16 [view ] -12.3147 130.4158 Deployed WeatherBalloon_in2019_v06
    2019-12-02 14:15 [view ] -12.3170 130.4147 Deployed WeatherBalloon_in2019_v06 14:15(UTC) launch
    2019-12-02 17:17 [view ] -12.3157 130.4087 Deployed WeatherBalloon_in2019_v06
    2019-12-02 20:21 [view ] -12.3162 130.4090 Deployed WeatherBalloon_in2019_v06
    2019-12-02 22:54 [view ] -12.3162 130.4130 Both Auto Trim in2019_v06_VSAT had unexplained outages on VSAT although sig str and tracking looked good. seems OK now
    2019-12-02 23:15 [view ] -12.3160 130.4133 Deployed WeatherBalloon_in2019_v06 Big one
    2019-12-03 02:15 [view ] -12.3152 130.4090 Deployed WeatherBalloon_in2019_v06
    2019-12-03 03:56 [view ] -12.3128 130.4082 POSMV [view] new usb GSM_in2019_v06 USB 5. Logging is automatic?? cannot stop/start
    2019-12-03 03:57 [view ] -12.3128 130.4082 POSMV [view] Start GSM_in2019_v06 Restart ethernet logging Session 3
    2019-12-03 05:13 [view ] -12.3155 130.4087 Deployed WeatherBalloon_in2019_v06
    2019-12-03 08:16 [view ] -12.3180 130.4145 Deployed WeatherBalloon_in2019_v06
    2019-12-03 10:15 [view ] -12.3173 130.4147 CPC 3772 [view] Maintenance in2019_v06_Atmospherics Filled and emptied butanol
    2019-12-03 11:15 [view ] -12.3162 130.4148 Deployed WeatherBalloon_in2019_v06
    2019-12-03 14:15 [view ] -12.3133 130.4152 Deployed WeatherBalloon_in2019_v06
    2019-12-03 17:12 [view ] -12.3157 130.4150 Deployed WeatherBalloon_in2019_v06
    2019-12-03 20:15 [view ] -12.3207 130.4143 Deployed WeatherBalloon_in2019_v06
    2019-12-03 20:53 [view ] -12.3203 130.4165 Picarro Spectrometer [view] Change in2019_v06_Atmospherics Restarted PC, changed active user to invesigator\support
    2019-12-03 21:59 [view ] -12.3117 130.4120 SMPS [view] Fault AIRBOX_in2019_v06 Failed to set scan time Checked SMPS distrbution for daily checks. Had the error "Failed to set scan time: not sampling". Unsure of how long it had this error/how long there was no sampling
    2019-12-03 22:43 [view ] -12.3117 130.4120 Picarro Spectrometer [view] Outage in2019_v06_Atmospherics Modifications to picarro logins. System now operating normally
    2019-12-03 23:15 [view ] -12.3113 130.4122 Deployed WeatherBalloon_in2019_v06
    2019-12-04 02:15 [view ] -12.3107 130.4103 Deployed WeatherBalloon_in2019_v06
    2019-12-04 02:57 [view ] -12.3112 130.4103 Underway Stephen Tibben Hydrochem Lab : TSG64 Sample TSG_Samples_in2019_v06
    2019-12-04 02:59 [view ] -12.3112 130.4103 Underway Stephen Tibben Hydrochem Lab : TSG65 Sample TSG_Samples_in2019_v06
    2019-12-04 03:01 [view ] -12.3112 130.4103 Underway Stephen Tibben Hydrochem Lab : TSG66 Sample TSG_Samples_in2019_v06
    2019-12-04 05:16 [view ] -12.3128 130.4107 Deployed WeatherBalloon_in2019_v06
    2019-12-04 08:15 [view ] -12.3125 130.4123 Deployed WeatherBalloon_in2019_v06 08:15 UTC Launch
    2019-12-04 11:16 [view ] -12.3143 130.4127 Deployed WeatherBalloon_in2019_v06
    2019-12-04 14:16 [view ] -12.3097 130.4132 Deployed WeatherBalloon_in2019_v06
    2019-12-04 17:15 [view ] -12.3112 130.4135 Deployed WeatherBalloon_in2019_v06
    2019-12-04 20:15 [view ] -12.3138 130.4120 Deployed WeatherBalloon_in2019_v06
    2019-12-04 22:54 [view ] -12.3145 130.4163 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapping CPCs CSIRO sampling
    2019-12-04 23:16 [view ] -12.3143 130.4163 Deployed WeatherBalloon_in2019_v06
    2019-12-05 00:45 [view ] -12.3127 130.4163 Stabilised Platform Maintenance in2019_v06_Atmospherics platform restarted restarted to upgrade to newest code. Includes data output to influx
    2019-12-05 02:13 [view ] -12.3112 130.4162 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_356.asvp
    2019-12-05 02:17 [view ] -12.3110 130.4162 Deployed WeatherBalloon_in2019_v06
    2019-12-05 05:16 [view ] -12.3090 130.4158 Deployed WeatherBalloon_in2019_v06
    2019-12-05 08:15 [view ] -12.3087 130.4160 Deployed WeatherBalloon_in2019_v06
    2019-12-05 11:14 [view ] -12.3107 130.4172 Deployed WeatherBalloon_in2019_v06
    2019-12-05 14:15 [view ] -12.3113 130.4173 Deployed WeatherBalloon_in2019_v06
    2019-12-05 14:36 [view ] -12.3108 130.4173 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_382.asvp
    2019-12-05 17:15 [view ] -12.3080 130.4175 Deployed WeatherBalloon_in2019_v06
    2019-12-05 19:24 [view ] -12.3055 130.4168 EM710 [view] Start GSM_in2019_v06 Start loggin EM710 towards Cullen Bay Drop passenger off Darwin
    2019-12-05 19:26 [view ] -12.3055 130.4168 SBP [view] Start GSM_in2019_v06 Start logging after CTD Drop passenger off Darwin, near Cullen Bay
    2019-12-05 19:27 [view ] -12.3055 130.4168 SBP [view] Start GSM_in2019_v06 Start loggin SBP120 towards Cullen Bay
    2019-12-05 19:28 [view ] -12.3053 130.4168 EM710 [view] SVP GSM_in2019_v06 Add new CTD from file seasave 2c 390
    2019-12-05 19:29 [view ] -12.3053 130.4168 Underway Stephen Tibben Hydrochem Lab : TSG67 Sample TSG_Samples_in2019_v06
    2019-12-05 19:30 [view ] -12.3053 130.4168 Underway Stephen Tibben Hydrochem Lab : TSG68 Sample TSG_Samples_in2019_v06
    2019-12-05 19:32 [view ] -12.3053 130.4168 Underway Stephen Tibben Hydrochem Lab : TSG69 Sample TSG_Samples_in2019_v06
    2019-12-05 20:16 [view ] -12.3103 130.5007 Deployed WeatherBalloon_in2019_v06
    2019-12-05 20:23 [view ] -12.3103 130.5230 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_394.asvp
    2019-12-05 22:03 [view ] -12.3815 130.7575 EM710 [view] Stop GSM_in2019_v06 Stopping at passenger de-embark spot
    2019-12-05 22:05 [view ] -12.3815 130.7575 SBP [view] Stop GSM_in2019_v06 Stopping at passenger de-embark spot
    2019-12-05 23:02 [view ] -12.3815 130.7575 EM710 [view] Start GSM_in2019_v06 Start logging EM710 return from dropoff passenger
    2019-12-05 23:02 [view ] -12.3815 130.7575 SBP [view] Start GSM_in2019_v06 Start logging SBP120 return from dropoff passenger
    2019-12-05 23:15 [view ] -12.3827 130.7577 Deployed WeatherBalloon_in2019_v06 23:15 (UTC) Launch
    2019-12-06 01:52 [view ] -12.3082 130.4223 SBP [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-06 01:53 [view ] -12.3095 130.4220 EM710 [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-06 02:16 [view ] -12.3102 130.4163 Deployed WeatherBalloon_in2019_v06
    2019-12-06 02:35 [view ] -12.3105 130.4163 Stabilised Platform Change in2019_v06_Atmospherics 5 point profile changed Profile changed from ((pitch, roll), 15s each): (0, -8), (0.0), (0, 8), (0,0), (-8,0), (0,0), (8,0), (0,0) to: (0, -8), (0.0), (-8, 0), (0,0), (0,8), (0,0), (8,0), (0,0)
    2019-12-06 03:17 [view ] -12.3025 130.4122 EM710 [view] Start GSM_in2019_v06 Start loggin EM710 towards Tiwi Is
    2019-12-06 03:17 [view ] -12.3012 130.4118 SBP [view] Start GSM_in2019_v06 Start loggin EM710 towards Tiwi Is
    2019-12-06 04:16 [view ] -12.1430 130.3532 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_394_modified.asvp SVP of original CTD modified for TSS 1547.2
    2019-12-06 05:06 [view ] -12.0065 130.2987 SBP [view] Stop GSM_in2019_v06 @ Station
    2019-12-06 05:09 [view ] -12.0062 130.2977 EM710 [view] Stop GSM_in2019_v06 Stop logging
    2019-12-06 05:16 [view ] -12.0057 130.2965 Deployed WeatherBalloon_in2019_v06
    2019-12-06 08:15 [view ] -12.0052 130.2965 Deployed WeatherBalloon_in2019_v06
    2019-12-06 08:50 [view ] -12.0055 130.2965 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_rctd_005.asvp Used rapid cast winch got a brake error so cast only to 15m
    2019-12-06 09:03 [view ] -12.0065 130.2965 EM710 [view] Start GSM_in2019_v06 Start logging transit C
    2019-12-06 09:07 [view ] -12.0073 130.2937 SBP [view] Start GSM_in2019_v06 Start logging transit
    2019-12-06 11:15 [view ] -12.1388 129.9875 Deployed WeatherBalloon_in2019_v06
    2019-12-06 14:16 [view ] -12.2768 130.2735 Deployed WeatherBalloon_in2019_v06
    2019-12-06 14:31 [view ] -12.2863 130.3153 EM710 [view] SVP GSM_in2019_v06 Rising TSS approaching station used old CTD394
    2019-12-06 15:11 [view ] -12.3118 130.4183 SBP [view] Stop GSM_in2019_v06 Stopped on station C
    2019-12-06 15:20 [view ] -12.3117 130.4180 EM710 [view] Stop GSM_in2019_v06 On Station Berrimah
    2019-12-06 17:15 [view ] -12.3125 130.4180 Deployed WeatherBalloon_in2019_v06
    2019-12-06 20:16 [view ] -12.3107 130.4182 Deployed WeatherBalloon_in2019_v06
    2019-12-06 20:16 [view ] -12.3107 130.4182 Deployed WeatherBalloon_in2019_v06
    2019-12-06 23:16 [view ] -12.3078 130.4162 Deployed WeatherBalloon_in2019_v06
    2019-12-06 23:36 [view ] -12.3080 130.4168 Aethelometer [view] Restart AIRBOX_in2019_v06 Restarted After Data Backup Backed up data to VHTDMA computer
    2019-12-07 02:16 [view ] -12.3122 130.4202 Deployed WeatherBalloon_in2019_v06
    2019-12-07 04:59 [view ] -12.3108 130.4167 EM710 [view] Start GSM_in2019_v06 LOgging whilst Drifting over
    2019-12-07 05:15 [view ] -12.3107 130.4063 Deployed WeatherBalloon_in2019_v06
    2019-12-07 06:43 [view ] -12.3095 130.3818 EM710 [view] Start GSM_in2019_v06 Start logging moving to next CTD station
    2019-12-07 07:59 [view ] -12.3068 130.4337 EM710 [view] SVP GSM_in2019_v06 Last CTD added. Still on station
    2019-12-07 08:15 [view ] -12.3072 130.4337 Deployed WeatherBalloon_in2019_v06
    2019-12-07 11:19 [view ] -12.3095 130.4350 Deployed WeatherBalloon_in2019_v06
    2019-12-07 14:14 [view ] -12.3112 130.4347 Deployed WeatherBalloon_in2019_v06
    2019-12-07 17:16 [view ] -12.3115 130.4345 Deployed WeatherBalloon_in2019_v06
    2019-12-07 20:15 [view ] -12.3153 130.4313 Deployed WeatherBalloon_in2019_v06 20:15 (UTC) Launch
    2019-12-07 22:26 [view ] -12.3148 130.4270 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-07 23:09 [view ] -12.3142 130.4267 Stabilised Platform Maintenance in2019_v06_Atmospherics added limit to acceleration. started playing at 22:22. finished now limiting the acceleration has massively reduced the wobble in the platform, as evidenced by the pitch/roll rates.
    2019-12-07 23:15 [view ] -12.3142 130.4265 Deployed WeatherBalloon_in2019_v06
    2019-12-08 02:15 [view ] -12.3148 130.4305 Deployed WeatherBalloon_in2019_v06
    2019-12-08 05:15 [view ] -12.3133 130.4308 Deployed WeatherBalloon_in2019_v06
    2019-12-08 08:15 [view ] -12.3102 130.4482 Deployed WeatherBalloon_in2019_v06
    2019-12-08 11:16 [view ] -12.3112 130.4318 Deployed WeatherBalloon_in2019_v06
    2019-12-08 14:16 [view ] -12.3112 130.4322 Deployed WeatherBalloon_in2019_v06
    2019-12-08 15:49 [view ] -12.3097 130.4328 POSMV [view] new usb GSM_in2019_v06 change to USB5
    2019-12-08 17:15 [view ] -12.3073 130.4385 Deployed WeatherBalloon_in2019_v06
    2019-12-08 20:15 [view ] -12.3085 130.4397 Deployed WeatherBalloon_in2019_v06
    2019-12-08 22:26 [view ] -12.3083 130.4315 Aethelometer [view] Fault AIRBOX_in2019_v06 Memory card not in properly Fixed
    2019-12-08 22:53 [view ] -12.3070 130.4308 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-08 22:53 [view ] -12.3070 130.4308 CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapped CPCs, QUT sampling
    2019-12-08 23:42 [view ] -12.3062 130.4307 Deployed WeatherBalloon_in2019_v06 Failed PTU sensor on the first one, had to do another one.
    2019-12-09 02:15 [view ] -12.3097 130.4323 Deployed WeatherBalloon_in2019_v06
    2019-12-09 03:27 [view ] -12.3065 130.4358 FAS – Filter Aerosol Samplers Observation in2019_v06_Atmospherics Totaliser interference and Cals Note: With right hand side totaliser calibrated (between times of samples 14 and 15) and still turning valves and pumps off (MFC’s were still on but have been changed to turn off when not in use now) when samplers are not in use the totalisers are still slowly counting. Over around two days these values were 1092.7m3 814.5m3 and 699.4m3 during the down time in the last few samples. Talking to Ian and he thinks it could be electrical interference. The values are zeroed before sampling so not sure if this is an issue or not. I’m still using the left hand side totaliser for the samples so they are consistent with the rest of the voyage and will calibrate the left one before packing up so the samples can be corrected. The difference between the left and the right last samples were 38615.9 (L) and 38816.7 (R/Calibrated) For most of the samples I’ve taken I’ve been putting a “L” for left and a “R” for right anyway.
    2019-12-09 05:15 [view ] -12.3072 130.4363 Deployed WeatherBalloon_in2019_v06
    2019-12-09 06:42 [view ] -12.3098 130.4068 EM710 [view] Start GSM_in2019_v06
    2019-12-09 07:47 [view ] -12.3860 130.2322 SBP [view] Start GSM_in2019_v06
    2019-12-09 08:20 [view ] -12.4767 130.1880 Deployed WeatherBalloon_in2019_v06
    2019-12-09 11:16 [view ] -12.6735 130.0912 Deployed WeatherBalloon_in2019_v06
    2019-12-09 14:15 [view ] -12.6765 130.0917 Deployed WeatherBalloon_in2019_v06 14:15(UTC) launch
    2019-12-09 17:16 [view ] -12.6727 130.0923 Deployed WeatherBalloon_in2019_v06
    2019-12-09 17:16 [view ] -12.6727 130.0923 Deployed WeatherBalloon_in2019_v06
    2019-12-09 20:17 [view ] -12.6727 130.0923 Deployed WeatherBalloon_in2019_v06
    2019-12-09 22:35 [view ] -12.6177 130.1193 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-09 23:07 [view ] -12.5477 130.1535 EM710 [view] Start GSM_in2019_v06 Transit return
    2019-12-09 23:12 [view ] -12.5370 130.1587 SBP [view] Start GSM_in2019_v06 Transit return
    2019-12-09 23:15 [view ] -12.5310 130.1617 Deployed WeatherBalloon_in2019_v06
    2019-12-09 23:17 [view ] -12.5263 130.1633 SBP [view] File GSM_in2019_v06 New segy file 038
    2019-12-10 00:03 [view ] -12.4295 130.2098 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_398_edit.asvp Edited the CTD file from 1549 to 1550 based on SST
    2019-12-10 01:24 [view ] -12.3173 130.3415 EM710 [view] SVP GSM_in2019_v06 Revert back to CTD SVP profile 398
    2019-12-10 01:58 [view ] -12.3078 130.4170 SBP [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-10 01:59 [view ] -12.3087 130.4182 EM710 [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-10 02:16 [view ] -12.3128 130.4158 Deployed WeatherBalloon_in2019_v06 End of tank - slow inflation.
    2019-12-10 05:18 [view ] -12.3077 130.4203 Deployed WeatherBalloon_in2019_v06
    2019-12-10 08:16 [view ] -12.3055 130.4212 Deployed WeatherBalloon_in2019_v06
    2019-12-10 10:26 [view ] -12.3057 130.4217 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold G050-Y30 Storm coming. Smell smoke coming from up the coast from around Darwin?
    2019-12-10 10:51 [view ] -12.3050 130.4210 Flask Sample Sample Taken in2019_v06_Atmospherics Flask Sample taken off Air Chem Lab Manifold G050-Y29 Storm coming. Smell smoke coming up te coast from around Darwin
    2019-12-10 11:15 [view ] -12.3047 130.4207 Deployed WeatherBalloon_in2019_v06
    2019-12-10 14:15 [view ] -12.3058 130.4222 Deployed WeatherBalloon_in2019_v06
    2019-12-10 17:32 [view ] -12.3048 130.4230 Deployed WeatherBalloon_in2019_v06
    2019-12-10 19:13 [view ] -12.3043 130.4232 Underway Stephen Tibben Hydrochem Lab : TSG70 Sample TSG_Samples_in2019_v06
    2019-12-10 19:14 [view ] -12.3043 130.4232 Underway Stephen Tibben Hydrochem Lab : TSG71 Sample TSG_Samples_in2019_v06
    2019-12-10 19:15 [view ] -12.3043 130.4232 Underway Stephen Tibben Hydrochem Lab : TSG72 Sample TSG_Samples_in2019_v06
    2019-12-10 20:16 [view ] -12.3043 130.4232 Deployed WeatherBalloon_in2019_v06
    2019-12-10 22:40 [view ] -12.3037 130.4232 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-10 23:07 [view ] -12.3028 130.4230 CCNC [view] Maintenance in2019_v06_Atmospherics MilliQ filled Zero check ok (0-1)
    2019-12-10 23:15 [view ] -12.3023 130.4227 Deployed WeatherBalloon_in2019_v06
    2019-12-11 02:16 [view ] -12.3055 130.4217 Deployed WeatherBalloon_in2019_v06
    2019-12-11 05:17 [view ] -12.3057 130.4222 Deployed WeatherBalloon_in2019_v06
    2019-12-11 08:15 [view ] -12.3012 130.4268 Deployed WeatherBalloon_in2019_v06 08:15 UTC Launch
    2019-12-11 11:16 [view ] -12.3120 130.2760 Deployed WeatherBalloon_in2019_v06
    2019-12-11 14:19 [view ] -12.3140 130.2730 Deployed WeatherBalloon_in2019_v06
    2019-12-11 17:39 [view ] -12.3110 130.2760 Deployed WeatherBalloon_in2019_v06 Launch. no ship temp and rh. Launched at 3:05
    2019-12-11 20:16 [view ] -12.3100 130.2760 Deployed WeatherBalloon_in2019_v06 Grafana not reporting Temperature or humidity - used values of 30 degrees and 70% respectively.
    2019-12-11 22:29 [view ] SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-11 22:29 [view ] CPC3772 [view] Fault AIRBOX_in2019_v06 CPC Low counts after filling liquid CPC reported low liquid level. Filled with butanol. CPC still showing low counts with an occasional spike to normal lvels. Will monitor to see if it improves. if not, switch to CSIRO CPC
    2019-12-11 23:04 [view ] CPC3772 [view] Maintenance AIRBOX_in2019_v06 Swapping CPCs CSIRO sampling Due to fault with QUT CPC (low counts even after liquid topup)
    2019-12-11 23:14 [view ] Deployed WeatherBalloon_in2019_v06
    2019-12-12 02:19 [view ] -12.3100 130.4182 Deployed WeatherBalloon_in2019_v06
    2019-12-12 03:10 [view ] -12.3160 130.2803 EM710 [view] Start GSM_in2019_v06 Start logging transit 8 mile track return
    2019-12-12 03:11 [view ] -12.3158 130.2808 SBP [view] Start GSM_in2019_v06 Start logging transit 8mile return
    2019-12-12 03:37 [view ] -12.3118 130.3260 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_400_edit.asvp
    2019-12-12 03:41 [view ] -12.3113 130.3340 SBP [view] File GSM_in2019_v06 restart processing file. No other changes
    2019-12-12 04:18 [view ] -12.3073 130.4122 SBP [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-12 04:20 [view ] -12.3075 130.4135 EM710 [view] Stop GSM_in2019_v06 Stop logging. Back on station
    2019-12-12 05:15 [view ] -12.3100 130.4150 Deployed WeatherBalloon_in2019_v06
    2019-12-12 08:16 [view ] -12.3090 130.4150 Deployed WeatherBalloon_in2019_v06
    2019-12-12 09:48 [view ] -12.3060 130.4138 EM710 [view] Start GSM_in2019_v06 Moving to deep water spot off Bathurst Island
    2019-12-12 09:49 [view ] -12.3048 130.4128 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_406.asvp
    2019-12-12 10:00 [view ] -12.2872 130.3993 SBP [view] Start GSM_in2019_v06
    2019-12-12 10:33 [view ] -12.2147 130.3933 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_406_modified.asvp ctd 406 modified for TSS
    2019-12-12 11:08 [view ] -12.1652 130.3112 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_woa09_001.asvp Profile created using WOA09
    2019-12-12 11:15 [view ] -12.1560 130.2920 Deployed WeatherBalloon_in2019_v06
    2019-12-12 12:42 [view ] -12.0175 130.0787 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_woa09_002.asvp
    2019-12-12 13:36 [view ] -11.8915 129.9657 CPC 3772 [view] Maintenance in2019_v06_Atmospherics Butanol filled and emptied
    2019-12-12 14:15 [view ] Deployed WeatherBalloon_in2019_v06
    2019-12-12 14:23 [view ] -11.7643 129.9065 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_xbt_032.asvp Only to 29m?? Extended to 150m manually
    2019-12-12 15:13 [view ] -11.6638 129.9005 SBP [view] Stop GSM_in2019_v06 On Station
    2019-12-12 16:30 [view ] -11.6618 129.9038 Microbiology_in2019_v06
    2019-12-12 16:30 [view ] -11.6618 129.9038 Microbiology_in2019_v06
    2019-12-12 17:15 [view ] -11.6630 129.9030 Deployed WeatherBalloon_in2019_v06
    2019-12-12 20:16 [view ] -11.6638 129.9035 Deployed WeatherBalloon_in2019_v06
    2019-12-12 22:43 [view ] -11.6590 129.9050 EM710 [view] Start GSM_in2019_v06 Trough mapping
    2019-12-12 22:45 [view ] -11.6585 129.9052 SBP [view] Start GSM_in2019_v06 Trough mapping
    2019-12-12 22:52 [view ] -11.6560 129.9058 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_415.asvp
    2019-12-12 23:04 [view ] -11.6325 129.9008 EM122 [view] SVP GSM_in2019_v06 Added 415 profile Need to correct line 0306 and 0307 for refraction
    2019-12-12 23:18 [view ] -11.6348 129.9063 Deployed WeatherBalloon_in2019_v06
    2019-12-12 23:30 [view ] -11.6523 129.9055 EM710 [view] Stop GSM_in2019_v06 Stop mapping of trough
    2019-12-12 23:31 [view ] -11.6520 129.9055 SBP [view] Stop GSM_in2019_v06 Stop mapping of trough, back on ctd station
    2019-12-13 00:00 [view ] -11.6457 129.9040 EM710 [view] Start GSM_in2019_v06 Drift back to original ctd station
    2019-12-13 00:28 [view ] -11.6615 129.9023 EM710 [view] Stop GSM_in2019_v06 Stop logging. Back on station after drifting
    2019-12-13 00:56 [view ] -11.6548 129.9040 EM710 [view] Start GSM_in2019_v06 Back to Darwin Station
    2019-12-13 00:57 [view ] -11.6545 129.9040 SBP [view] Start GSM_in2019_v06 Start logging back to Darwin Station
    2019-12-13 00:58 [view ] -11.6543 129.9040 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_416.asvp
    2019-12-13 01:12 [view ] -11.6735 129.9010 EM710 [view] SVP GSM_in2019_v06 New SVP applied in2019_v06_CTD_417.asvp
    2019-12-13 01:47 [view ] -11.7558 129.9017 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_ctd_417_edit.asvp May have to look at refraction edits for 315 and 316
    2019-12-13 02:16 [view ] -11.8305 129.9142 Deployed WeatherBalloon_in2019_v06 02:15 (UTC) Launch
    2019-12-13 03:13 [view ] -11.9643 130.0152 EM710 [view] SVP GSM_in2019_v06 Reverted back to SVP file in2019_v06_ctd_417.asvp
    2019-12-13 05:00 [view ] -12.2025 130.2712 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_xbt_033.asvp
    2019-12-13 05:16 [view ] -12.2398 130.3125 Deployed WeatherBalloon_in2019_v06
    2019-12-13 05:59 [view ] -12.3125 130.4173 EM710 [view] Stop GSM_in2019_v06 On station
    2019-12-13 08:14 [view ] -12.3105 130.4178 Deployed WeatherBalloon_in2019_v06
    2019-12-13 09:23 [view ] -12.3082 130.4247 Deployed WeatherBalloon_in2019_v06 Special balloon for the storm
    2019-12-13 11:15 [view ] -12.3093 130.4307 Deployed WeatherBalloon_in2019_v06
    2019-12-13 14:11 [view ] -12.3097 130.4198 POSMV [view] new usb GSM_in2019_v06 usb6
    2019-12-13 14:16 [view ] -12.3098 130.4198 Deployed WeatherBalloon_in2019_v06 Still missing temp and RH - used 30 C and 70% respectively.
    2019-12-13 14:51 [view ] -12.3103 130.4197 Underway Jack McDonald Hydrochem Lab : TSG73 Sample TSG_Samples_in2019_v06
    2019-12-13 14:55 [view ] -12.3103 130.4197 Underway Jack McDonald Hydrochem Lab : TSG74 Sample TSG_Samples_in2019_v06
    2019-12-13 14:57 [view ] -12.3103 130.4197 Underway Jack McDonald Hydrochem Lab : TSG75 Sample TSG_Samples_in2019_v06
    2019-12-13 17:16 [view ] -12.3137 130.4198 Deployed WeatherBalloon_in2019_v06
    2019-12-13 20:16 [view ] -12.3100 130.4342 Deployed WeatherBalloon_in2019_v06
    2019-12-13 23:16 [view ] -12.3090 130.4348 Deployed WeatherBalloon_in2019_v06
    2019-12-13 23:21 [view ] -12.3087 130.4348 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
    2019-12-14 02:16 [view ] -12.3095 130.4107 Deployed WeatherBalloon_in2019_v06 waterspouts 30 min ago
    2019-12-14 05:14 [view ] -12.3123 130.4097 Deployed WeatherBalloon_in2019_v06
    2019-12-14 08:15 [view ] -12.3097 130.4243 Deployed WeatherBalloon_in2019_v06
    2019-12-14 09:42 [view ] -12.3115 130.4245 CPC3772 [view] Stop AIRBOX_in2019_v06 End of sampling shutdown
    2019-12-14 09:43 [view ] -12.3115 130.4245 SMPS [view] Stop AIRBOX_in2019_v06 End of sampling shutdown
    2019-12-14 09:43 [view ] -12.3115 130.4245 CIMS [view] Stop AIRBOX_in2019_v06 End of sampling shutdown
    2019-12-14 09:43 [view ] -12.3115 130.4245 Aethelometer [view] Stop AIRBOX_in2019_v06 End of sampling shutdown
    2019-12-14 11:15 [view ] -12.3120 130.4245 Deployed WeatherBalloon_in2019_v06
    2019-12-14 14:15 [view ] -12.3115 130.4162 Deployed WeatherBalloon_in2019_v06
    2019-12-14 17:16 [view ] -12.3155 130.4173 Deployed WeatherBalloon_in2019_v06
    2019-12-14 20:16 [view ] -12.3125 130.4182 Deployed WeatherBalloon_in2019_v06 20:15 (UTC) Launch
    2019-12-14 20:43 [view ] -12.3118 130.4182 Stabilised Platform Fault in2019_v06_Atmospherics streaming collector briefly stopped will have to repopulate current hour from raw file
    2019-12-14 23:15 [view ] -12.3075 130.4170 Deployed WeatherBalloon_in2019_v06
    2019-12-15 02:15 [view ] -12.3113 130.4143 Deployed WeatherBalloon_in2019_v06
    2019-12-15 05:15 [view ] -12.3155 130.4137 Deployed WeatherBalloon_in2019_v06
    2019-12-15 08:17 [view ] -12.3122 130.4167 Deployed WeatherBalloon_in2019_v06
    2019-12-15 11:15 [view ] -12.3108 130.4165 Deployed WeatherBalloon_in2019_v06
    2019-12-15 14:16 [view ] -12.3095 130.4152 Deployed WeatherBalloon_in2019_v06
    2019-12-15 17:15 [view ] -12.3123 130.4128 Deployed WeatherBalloon_in2019_v06
    2019-12-15 20:30 [view ] -12.3093 130.4147 Deployed WeatherBalloon_in2019_v06
    2019-12-15 23:16 [view ] -12.3095 130.4147 Deployed WeatherBalloon_in2019_v06
    2019-12-16 02:15 [view ] -12.3097 130.4140 Deployed WeatherBalloon_in2019_v06
    2019-12-16 05:17 [view ] -12.3080 130.4137 Deployed WeatherBalloon_in2019_v06 Could not get RH value - used estimate of 70%.
    2019-12-16 08:14 [view ] -12.3100 130.4140 Deployed WeatherBalloon_in2019_v06
    2019-12-16 11:16 [view ] -12.3070 130.4143 Deployed WeatherBalloon_in2019_v06
    2019-12-16 14:18 [view ] -12.3073 130.4140 Deployed WeatherBalloon_in2019_v06 14:15(UTC) launch Thanks guys, hope you got some good data :)
    2019-12-16 14:34 [view ] -12.3058 130.4125 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_018.asvp
    2019-12-16 14:35 [view ] -12.3055 130.4130 EM710 [view] Start GSM_in2019_v06
    2019-12-16 14:41 [view ] -12.3048 130.4203 SBP [view] Start GSM_in2019_v06
    2019-12-16 18:35 [view ] -12.3078 130.6020 EM710 [view] SVP GSM_in2019_v06 New SVP Applied in2019_v06_RTOFS_018_edit.asvp
    2019-12-16 18:48 [view ] -12.3058 130.6005 SBP [view] Stop GSM_in2019_v06 Waiting for 45min to enter port
    2019-12-16 18:49 [view ] -12.3058 130.6007 EM710 [view] Stop GSM_in2019_v06 Waiting for 45min to enter port
    2019-12-16 19:20 [view ] -12.3037 130.6040 EM710 [view] Start GSM_in2019_v06 Start loggin EM710 towards Darwin port
    2019-12-16 19:20 [view ] -12.3033 130.6042 SBP [view] Start GSM_in2019_v06 Start loggin EM710 towards Darwin port
    2019-12-16 19:45 [view ] -12.3130 130.6523 Stabilised Platform Stop in2019_v06_Atmospherics tracking stopped for port
    2019-12-16 20:17 [view ] -12.3400 130.7150 Picarro Spectrometer [view] Maintenance in2019_v06_Atmospherics Calibration Started
    2019-12-16 21:01 [view ] -12.4203 130.7763 EM710 [view] Stop GSM_in2019_v06 Pilot onboard, heading into Darwin port
    2019-12-16 21:02 [view ] -12.4223 130.7778 SBP [view] Stop GSM_in2019_v06 Pilot onboard, heading into Darwin port
    2019-12-16 22:46 [view ] -12.4718 130.8468 Gravity Meter [view] Stop GSM_in2019_v06 At Darwin Port
    2019-12-16 23:44 [view ] Picarro Spectrometer [view] Maintenance in2019_v06_Atmospherics Calibration complete
    2019-12-17 00:03 [view ] Aerosol Lab [view] Change in2019_v06_Atmospherics Lab temp reduced to 22 for port period
    2019-12-18 01:11 [view ] MAAP [view] Maintenance in2019_v06_Atmospherics VSCC cleaned a little bit of black carbon, but not too bad
    2019-12-18 01:24 [view ] MAAP [view] Maintenance in2019_v06_Atmospherics HEPA zero check Tested with zero filter 1036015 Zero check passed - instrument reports zero as expected
    2019-12-18 01:42 [view ] MAAP [view] Maintenance in2019_v06_Atmospherics Flow check Tested flow with Gilibrator with high flow cell 1810008-H. Air drawn from Lab, plumbed into MAAP input System nominal (MAAP reported) flow: 448Nl/h, 500l/h Gilibrator flow (average of 5): 8.008 L/min
    2019-12-18 02:10 [view ] CCNC [view] Maintenance in2019_v06_Atmospherics Quarterly maintenance Sheath filter replaced. Desiccant tube inspected, looks good Sample flow calibration not possible - standard flow gilibrator cell not here (getting repaired) OPC water trap has no liquid MilliQ refilled HEPA zero good 0-1

    Save this list as

    Deployments by start time:- Click on column header to sort. Use link on 'Deployment' to see full details. Use the CSV button at the bottom to export data (tab delimited).

    Search for deployments from this voyage and others

    Deployment OperationStationCastGearProject Start and end timesStart LocationEnd LocationDepthDescription
    Underway System [details]   Air Sampling Inlet Mode,Air Temperature Sensor - ROTRONIC T&RH HC2A-S3,Air Temperature Sensor - ROTRONIC T&RH HC2A-S3,Air Temperature Sensor - ROTRONIC T&RH HC2A-S3,Air Temperature Sensor - ROTRONIC T&RH HC2A-S3,Autosal Salinometer,Burket Flow meter,Burket Flow meter,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO Hobart pCO2,CSIRO air sampling inlet,CSIRO air sampling inlet,Chelsea Chelsea Aquatracka III Fluorometer,Depth: TECHSAS-DERIVED. For more information contact the Data Acquisition and Processing group.,Fluorometer Concentration,Gyrocompass,IMOS Port Pyranometer-SN 35122F3,IMOS Port Radiometer-SN 29140F3,IMOS Stbd Pyranometer-SN 29125F3,IMOS Stbd Radiometer-SN 29140F3,IMOS wind monitor,IMOS wind monitor,IMOS wind monitor,IMOS wind monitor,ISAR SST,Kobold MIK-C Flow meter,Kobold MIK-C Fluorometer Flow Meter,Kongsberg Maritime Skipper DL850 doppler log,Kongsberg Maritime Skipper DL850 doppler log,Kongsberg Maritime Skipper DL850 doppler log,Kongsberg Maritime Skipper DL850 doppler log,Kongsberg Maritime Skipper DL850 doppler log,Kongsberg Maritime Skipper DL850 doppler log,LI-COR LI-190R Quantum Sensor,LI-COR LI-190R Quantum Sensor,MAAP Status,Multiangle Absorption Photometer (MAAP),Multiangle Absorption Photometer (MAAP),Optode Dissolved Oxygen Concentration,Optode Dissolved Oxygen Concentration,Optode Dissolved Oxygen Concentration,Ozone Monitor RVT1,Ozone Monitor RVT1,Ozone Monitor RVT2,Ozone Monitor RVT2,Picarro Greenhouse Gas Spectrometer CO2,CH4,H2o,Picarro Greenhouse Gas Spectrometer CO2,CH4,H2o,Picarro Greenhouse Gas Spectrometer CO2,CH4,H2o,Port Dew Point,Port Rain Gauge,Port drop keel sensor,RM Young 05106 wind monitor-75621,RM Young 05106 wind monitor-75621,RM Young 05106 wind monitor-75621,RM Young 05106 wind monitor-75621,RM Young Wind Sensor Type 05106,RM Young Wind Sensor Type 05106,RM Young Wind Sensor Type 05106,RM Young Wind Sensor Type 05106,RM Young Wind Sensor Type 05107,Remote Temperature (T) - SN 1061,Seapath 330+,Seapath 330+,Seapath 330+,Seapath 330+,Starboard Dew Point,Starboard Rain Gauge,Starboard drop keel sensor,ThermoSalinoGraph (TSG)-SN 3439,Vaisala Ship's Barometer PTB330 2019-10-19 10:32 2019-11-10 09:22 -12.4722 130.8460 -12.4724 130.8455
    ADCP Data [details]   Teledyne RDI ADCP 150 kHz 2549 2019-10-19 22:24 2019-12-17 08:59 -12.4211 130.7783 -12.4718 130.8468 781.9
    CTD Cast / Hydrology [details]   Cast 1 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-21 07:34 2019-10-21 07:51 -13.3240 123.7075
    CTD Cast / Hydrology [details]   Cast 2 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-21 15:45 2019-10-21 16:16 -13.4989 122.5010
    CTD Cast / Hydrology [details]   Cast 3 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-21 19:24 2019-10-21 20:15 -13.1703 122.1006
    CTD Cast / Hydrology [details]   Cast 4 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-22 12:20 2019-10-22 14:01 -13.8796 120.5503
    CTD Cast / Hydrology [details]   Cast 5 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-22 21:25 2019-10-22 21:59 -14.6709 121.6726
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 19:33 40.1
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 19:36 966.8
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 20:14 997.4
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 21:14 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 21:23 1020.1
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-23 22:09 939.8
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 00:01 999.8
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 01:17 1093.8
    Towed CTD [details] 1   Triaxus 2019-10-24 01:54 2019-10-24 04:56 -14.2930 121.2613 -14.2408 121.0886 106 Leg 1Leg3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 05:16 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 05:43 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 06:35 930.7
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 06:46 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 07:31 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 08:44 1090.2
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 09:36 1100.3
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-24 10:32 1042.8
    CTD Cast / Hydrology [details]   Cast 6 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-24 10:42 2019-10-24 12:18 -14.2505 121.1959
    Towed CTD [details] 1   Triaxus 2019-10-24 11:25 2019-10-24 20:23 -14.2565 121.2796 -14.3492 121.2388 106 Leg 1Leg4
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-25 02:00 1001
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-25 03:02 1000.4
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-25 04:08 822.6
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-25 04:16 1032.6
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-25 05:11 950
    Towed CTD [details] 1   Triaxus 2019-10-26 04:44 2019-10-26 14:48 -14.3487 121.2463 -14.3489 121.2351 103 Leg 1Leg6
    CTD Cast / Hydrology [details]   Cast 7 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-26 09:33 2019-10-26 10:03 -14.0381 122.2272
    CTD Cast [details]   Cast 8 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 01:28 2019-10-27 02:10 -13.4898 121.5301
    CTD Cast [details]   Cast 9 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 03:29 2019-10-27 04:13 -13.4905 121.5300
    CTD Cast [details]   Cast 10 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 05:29 2019-10-27 06:20 -13.4901 121.5299
    CTD Cast / Hydrology [details]   Cast 11 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 07:29 2019-10-27 08:18 -13.4889 121.5300
    CTD Cast [details]   Cast 12 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 09:29 2019-10-27 10:06 -13.4888 121.5316
    CTD Cast [details]   Cast 13 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 11:29 2019-10-27 12:06 -13.4901 121.5310
    CTD Cast / Hydrology [details]   Cast 14 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 13:29 2019-10-27 14:09 -13.4901 121.5302
    CTD Cast [details]   Cast 15 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 15:29 2019-10-27 16:06 -13.4896 121.5299
    CTD Cast [details]   Cast 16 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 17:25 2019-10-27 18:07 -13.4898 121.5302
    CTD Cast [details]   Cast 17 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 19:28 2019-10-27 20:03 -13.4888 121.5312
    CTD Cast [details]   Cast 18 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 21:29 2019-10-27 22:06 -13.4881 121.5297
    CTD Cast [details]   Cast 19 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-27 23:28 2019-10-28 00:04 -13.4903 121.5294
    CTD Cast / Hydrology [details]   Cast 20 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 01:28 2019-10-28 02:14 -13.4899 121.5304
    CTD Cast [details]   Cast 21 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 03:30 2019-10-28 04:07 -13.4897 121.5302
    CTD Cast [details]   Cast 22 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 05:29 2019-10-28 06:08 -13.4900 121.5302
    CTD Cast [details]   Cast 23 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 07:29 2019-10-28 08:06 -13.4878 121.5305
    CTD Cast [details]   Cast 24 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 09:30 2019-10-28 10:06 -13.4875 121.5309
    CTD Cast [details]   Cast 25 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 11:29 2019-10-28 12:06 -13.4894 121.5293
    CTD Cast [details]   Cast 26 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 13:29 2019-10-28 14:05 -13.4902 121.5304
    CTD Cast [details]   Cast 27 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 15:31 2019-10-28 16:07 -13.4880 121.5310
    CTD Cast [details]   Cast 28 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 17:30 2019-10-28 18:05 -13.4897 121.5300
    CTD Cast [details]   Cast 29 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 19:31 2019-10-28 20:10 -13.4889 121.5316
    CTD Cast [details]   Cast 30 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 21:29 2019-10-28 22:05 -13.4889 121.5311
    CTD Cast [details]   Cast 31 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-28 23:31 2019-10-29 00:09 -13.4901 121.5297
    CTD Cast / Hydrology [details]   Cast 32 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 01:30 2019-10-29 02:35 -13.4895 121.5302
    CTD Cast [details]   Cast 33 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 05:54 2019-10-29 06:20 -13.7974 121.9579
    CTD Cast [details]   Cast 34 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 07:59 2019-10-29 08:20 -13.7979 121.9571
    CTD Cast / Hydrology [details]   Cast 35 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 09:59 2019-10-29 10:30 -13.7993 121.9570
    CTD Cast [details]   Cast 36 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 11:59 2019-10-29 12:20 -13.7980 121.9578
    CTD Cast [details]   Cast 37 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 14:04 2019-10-29 14:24 -13.7986 121.9582
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-29 15:34 966.3
    CTD Cast [details]   Cast 38 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 16:01 2019-10-29 16:21 -13.7979 121.9577
    CTD Cast [details]   Cast 39 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 17:59 2019-10-29 18:21 -13.7980 121.9575
    CTD Cast [details]   Cast 40 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 19:01 2019-10-29 19:23 -13.7981 121.9560
    CTD Cast [details]   Cast 41 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 19:59 2019-10-29 20:20 -13.7989 121.9561
    CTD Cast / Hydrology [details]   Cast 42 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-29 21:58 2019-10-29 22:45 -13.7994 121.9575
    CTD Cast [details]   Cast 43 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 00:05 2019-10-30 00:25 -13.7980 121.9584
    CTD Cast [details]   Cast 44 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 01:59 2019-10-30 02:20 -13.7975 121.9587
    CTD Cast / Hydrology [details]   Cast 45 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 03:58 2019-10-30 04:36 -13.7970 121.9596
    CTD Cast [details]   Cast 46 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 06:03 2019-10-30 06:26 -13.7980 121.9572
    CTD Cast [details]   Cast 47 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 08:03 2019-10-30 08:25 -13.7986 121.9574
    CTD Cast [details]   Cast 48 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 09:59 2019-10-30 10:19 -13.7968 121.9561
    CTD Cast [details]   Cast 49 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 11:59 2019-10-30 12:19 -13.7979 121.9580
    CTD Cast [details]   Cast 50 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 13:59 2019-10-30 14:21 -13.7981 121.9582
    CTD Cast [details]   Cast 51 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 15:59 2019-10-30 16:19 -13.7973 121.9582
    CTD Cast [details]   Cast 52 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 18:00 2019-10-30 18:19 -13.7976 121.9573
    CTD Cast [details]   Cast 53 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 19:59 2019-10-30 20:19 -13.7981 121.9576
    CTD Cast [details]   Cast 54 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-30 21:59 2019-10-30 22:19 -13.7990 121.9576
    CTD Cast / Hydrology [details]   Cast 55 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-31 00:00 2019-10-31 00:38 -13.7979 121.9578
    CTD Cast [details]   Cast 56 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-31 02:00 2019-10-31 02:21 -13.7977 121.9584
    CTD Cast [details]   Cast 57 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-31 03:59 2019-10-31 04:21 -13.7976 121.9584
    CTD Cast / Hydrology [details]   Cast 58 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-31 05:59 2019-10-31 06:34 -13.7978 121.9577
    CTD Cast [details]   Cast 59 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-10-31 08:01 2019-10-31 08:22 -13.7979 121.9584
    XBT Cast [details]   Sippican Deep Blue 2548 2019-10-31 21:33 769.3
    CTD Cast / Hydrology [details]   Cast 60 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-01 08:39 2019-11-01 10:45 -14.2726 121.3237
    Towed CTD [details] 2   Triaxus 2019-11-01 23:47 2019-11-02 11:59 -14.3570 121.3576 -14.1902 121.3910 106 Leg 2Leg1
    Towed CTD [details] 2   Triaxus 2019-11-02 12:26 2019-11-03 00:09 -14.2025 121.3931 -14.3136 121.2546 106 Leg 2Leg2
    Towed CTD [details] 2   Triaxus 2019-11-03 00:39 2019-11-03 14:11 -14.3331 121.2544 -14.2011 121.3503 106 Leg 2Leg3
    CTD Cast / Hydrology [details]   Cast 61 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-03 04:45 2019-11-03 06:27 -14.2830 121.3615
    CTD Cast / Hydrology [details]   Cast 62 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-03 08:10 2019-11-03 09:01 -14.2017 121.3465
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-03 14:39 1100.3
    Towed CTD [details] 2   Triaxus 2019-11-03 20:18 2019-11-04 09:47 -14.2012 121.3378 -14.3096 121.4622 106 Leg 2Leg4
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-04 10:01 1100.3
    Towed CTD [details] 2   Triaxus 2019-11-04 13:15 2019-11-04 21:46 -14.2572 121.4604 -14.3921 121.3740 105.7 Leg 2Leg6
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-04 22:16 939.8
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-04 23:21 597.2
    CTD Cast / Hydrology [details]   Cast 63 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 03:45 2019-11-05 04:30 -13.7973 121.9564
    CTD Cast [details]   Cast 64 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 09:29 2019-11-05 09:51 -13.7980 121.9577
    CTD Cast [details]   Cast 65 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 11:29 2019-11-05 11:51 -13.7979 121.9578
    CTD Cast [details]   Cast 66 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 13:23 2019-11-05 13:52 -13.7977 121.9578
    CTD Cast [details]   Cast 67 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 15:37 2019-11-05 16:02 -13.7980 121.9581
    CTD Cast [details]   Cast 68 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 17:22 2019-11-05 17:49 -13.7978 121.9579
    CTD Cast [details]   Cast 69 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 19:29 2019-11-05 19:49 -13.7987 121.9568
    CTD Cast [details]   Cast 70 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 21:29 2019-11-05 21:49 -13.7980 121.9572
    CTD Cast [details]   Cast 71 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-05 23:29 2019-11-05 23:50 -13.7974 121.9579
    CTD Cast [details]   Cast 72 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 01:30 2019-11-06 01:49 -13.7976 121.9575
    CTD Cast / Hydrology [details]   Cast 73 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 03:30 2019-11-06 04:16 -13.7973 121.9575
    CTD Cast [details]   Cast 74 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 05:29 2019-11-06 05:49 -13.7978 121.9577
    CTD Cast [details]   Cast 75 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 07:21 2019-11-06 07:49 -13.7980 121.9595
    CTD Cast [details]   Cast 76 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 09:21 2019-11-06 09:49 -13.7975 121.9576
    CTD Cast [details]   Cast 77 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 11:29 2019-11-06 11:49 -13.7977 121.9582
    CTD Cast [details]   Cast 78 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 13:29 2019-11-06 13:49 -13.7977 121.9579
    CTD Cast [details]   Cast 79 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 15:32 2019-11-06 15:52 -13.7978 121.9578
    CTD Cast [details]   Cast 80 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 17:29 2019-11-06 17:49 -13.7978 121.9581
    CTD Cast [details]   Cast 81 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 19:19 2019-11-06 19:49 -13.7975 121.9572
    CTD Cast [details]   Cast 82 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 21:29 2019-11-06 21:49 -13.7981 121.9576
    CTD Cast [details]   Cast 83 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-06 23:29 2019-11-06 23:49 -13.7973 121.9577
    CTD Cast / Hydrology [details]   Cast 84 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 01:29 2019-11-07 02:20 -13.7976 121.9579
    CTD Cast [details]   Cast 85 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 03:30 2019-11-07 03:50 -13.7975 121.9580
    CTD Cast [details]   Cast 86 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 05:29 2019-11-07 05:49 -13.7977 121.9580
    CTD Cast [details]   Cast 87 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 07:29 2019-11-07 07:50 -13.7973 121.9595
    CTD Cast [details]   Cast 88 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 09:29 2019-11-07 09:48 -13.7975 121.9574
    CTD Cast [details]   Cast 89 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 11:25 2019-11-07 11:49 -13.7978 121.9577
    CTD Cast [details]   Cast 90 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 13:29 2019-11-07 13:49 -13.7976 121.9578
    CTD Cast [details]   Cast 91 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 15:29 2019-11-07 15:49 -13.7980 121.9578
    CTD Cast [details]   Cast 92 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 17:31 2019-11-07 17:51 -13.7975 121.9578
    CTD Cast [details]   Cast 93 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 19:29 2019-11-07 19:49 -13.7983 121.9570
    CTD Cast / Hydrology [details]   Cast 94 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-07 21:29 2019-11-07 22:12 -13.7982 121.9583
    CTD Cast / Hydrology [details]   Cast 95 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-08 03:54 2019-11-08 04:42 -14.4182 121.3699
    CTD Cast / Hydrology [details]   Cast 96 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-08 14:18 2019-11-08 14:39 -13.4996 122.5011
    CTD Cast / Hydrology [details]   Cast 97 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-13 01:12 2019-11-13 01:24 -11.2051 133.4331
    CTD Cast / Hydrology [details]   Cast 98 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-13 03:35 2019-11-13 03:46 -11.2078 133.4319
    CTD Cast / Hydrology [details]   Cast 99 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 01:05 2019-11-14 01:13 -11.2070 133.4305
    CTD Cast [details]   Cast 100 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 19:29 2019-11-14 19:34 -11.2062 133.4353
    CTD Cast [details]   Cast 101 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 20:01 2019-11-14 20:05 -11.2052 133.4380
    CTD Cast [details]   Cast 102 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 20:32 2019-11-14 20:36 -11.2041 133.4412
    CTD Cast [details]   Cast 103 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 21:00 2019-11-14 21:05 -11.2044 133.4426
    CTD Cast [details]   Cast 104 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 21:30 2019-11-14 21:34 -11.2068 133.4426
    CTD Cast [details]   Cast 105 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 21:59 2019-11-14 22:04 -11.2074 133.4444
    CTD Cast [details]   Cast 106 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 22:29 2019-11-14 22:34 -11.2074 133.4463
    CTD Cast [details]   Cast 107 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 22:59 2019-11-14 23:04 -11.2073 133.4469
    CTD Cast [details]   Cast 108 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 23:30 2019-11-14 23:34 -11.2073 133.4469
    CTD Cast [details]   Cast 109 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-14 23:59 2019-11-15 00:04 -11.2077 133.4459
    CTD Cast [details]   Cast 110 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 00:29 2019-11-15 00:34 -11.2066 133.4450
    CTD Cast [details]   Cast 111 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 00:58 2019-11-15 01:05 -11.2051 133.4455
    CTD Cast [details]   Cast 112 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 01:29 2019-11-15 01:34 -11.2040 133.4460
    CTD Cast [details]   Cast 113 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 01:59 2019-11-15 02:04 -11.2009 133.4464
    CTD Cast [details]   Cast 114 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 02:30 2019-11-15 02:35 -11.2008 133.4465
    CTD Cast [details]   Cast 115 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 03:00 2019-11-15 03:05 -11.2012 133.4462
    CTD Cast [details]   Cast 116 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 03:30 2019-11-15 03:35 -11.2020 133.4458
    CTD Cast [details]   Cast 117 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 03:59 2019-11-15 04:04 -11.2027 133.4455
    CTD Cast [details]   Cast 118 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 04:30 2019-11-15 04:35 -11.2039 133.4450
    CTD Cast [details]   Cast 119 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 05:00 2019-11-15 05:05 -11.2062 133.4441
    CTD Cast [details]   Cast 120 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 05:30 2019-11-15 05:34 -11.2099 133.4431
    CTD Cast [details]   Cast 121 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 06:00 2019-11-15 06:04 -11.2145 133.4433
    CTD Cast [details]   Cast 122 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 06:30 2019-11-15 06:34 -11.2218 133.4442
    CTD Cast [details]   Cast 123 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 06:59 2019-11-15 07:04 -11.2314 133.4454
    CTD Cast [details]   Cast 124 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 07:30 2019-11-15 07:34 -11.2307 133.4450
    CTD Cast [details]   Cast 125 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 07:59 2019-11-15 08:04 -11.2246 133.4451
    CTD Cast [details]   Cast 126 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 08:29 2019-11-15 08:34 -11.2249 133.4459
    CTD Cast [details]   Cast 127 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 09:02 2019-11-15 09:06 -11.2194 133.4458
    CTD Cast [details]   Cast 128 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 09:29 2019-11-15 09:34 -11.2151 133.4440
    CTD Cast [details]   Cast 129 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 09:59 2019-11-15 10:04 -11.2106 133.4413
    CTD Cast [details]   Cast 130 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 10:29 2019-11-15 10:34 -11.2057 133.4382
    CTD Cast [details]   Cast 131 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 10:59 2019-11-15 11:04 -11.2059 133.4377
    CTD Cast [details]   Cast 132 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 11:29 2019-11-15 11:34 -11.2062 133.4371
    CTD Cast [details]   Cast 133 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 11:59 2019-11-15 12:04 -11.2068 133.4358
    CTD Cast [details]   Cast 134 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 12:29 2019-11-15 12:35 -11.2074 133.4348
    CTD Cast [details]   Cast 135 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 12:59 2019-11-15 13:04 -11.2070 133.4341
    CTD Cast [details]   Cast 136 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 13:30 2019-11-15 13:34 -11.2070 133.4340
    CTD Cast [details]   Cast 137 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 14:00 2019-11-15 14:04 -11.2065 133.4336
    CTD Cast [details]   Cast 138 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 14:29 2019-11-15 14:34 -11.2063 133.4334
    CTD Cast [details]   Cast 139 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 15:00 2019-11-15 15:04 -11.2058 133.4332
    CTD Cast [details]   Cast 140 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 15:30 2019-11-15 15:34 -11.2060 133.4332
    CTD Cast [details]   Cast 141 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 15:59 2019-11-15 16:04 -11.2070 133.4333
    CTD Cast [details]   Cast 142 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 16:29 2019-11-15 16:34 -11.2076 133.4335
    CTD Cast [details]   Cast 143 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 17:00 2019-11-15 17:05 -11.2089 133.4343
    CTD Cast [details]   Cast 144 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 17:29 2019-11-15 17:33 -11.2094 133.4350
    CTD Cast [details]   Cast 145 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 17:59 2019-11-15 18:04 -11.2099 133.4361
    CTD Cast [details]   Cast 146 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 18:29 2019-11-15 18:34 -11.2100 133.4366
    CTD Cast [details]   Cast 147 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 18:59 2019-11-15 19:04 -11.2102 133.4374
    CTD Cast [details]   Cast 148 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 19:29 2019-11-15 19:34 -11.2102 133.4374
    CTD Cast [details]   Cast 149 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 19:59 2019-11-15 20:04 -11.2099 133.4379
    CTD Cast [details]   Cast 150 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 20:29 2019-11-15 20:34 -11.2093 133.4391
    CTD Cast [details]   Cast 151 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 20:59 2019-11-15 21:04 -11.2083 133.4407
    CTD Cast [details]   Cast 152 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 21:30 2019-11-15 21:35 -11.2072 133.4428
    CTD Cast [details]   Cast 153 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 21:58 2019-11-15 22:03 -11.2067 133.4434
    CTD Cast [details]   Cast 154 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 22:30 2019-11-15 22:35 -11.2067 133.4434
    CTD Cast [details]   Cast 155 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 23:00 2019-11-15 23:05 -11.2066 133.4434
    CTD Cast [details]   Cast 156 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-15 23:29 2019-11-15 23:35 -11.2063 133.4436
    CTD Cast [details]   Cast 157 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 00:00 2019-11-16 00:05 -11.2060 133.4438
    CTD Cast [details]   Cast 158 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 00:32 2019-11-16 00:36 -11.2054 133.4437
    CTD Cast [details]   Cast 159 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 01:00 2019-11-16 01:04 -11.2048 133.4439
    CTD Cast [details]   Cast 160 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 01:30 2019-11-16 01:34 -11.2050 133.4437
    CTD Cast [details]   Cast 161 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 01:59 2019-11-16 02:04 -11.2052 133.4436
    CTD Cast [details]   Cast 162 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 02:30 2019-11-16 02:34 -11.2056 133.4433
    CTD Cast [details]   Cast 163 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 03:00 2019-11-16 03:04 -11.2064 133.4426
    CTD Cast [details]   Cast 164 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 03:29 2019-11-16 03:34 -11.2075 133.4418
    CTD Cast [details]   Cast 165 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 03:59 2019-11-16 04:05 -11.2092 133.4405
    CTD Cast [details]   Cast 166 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 04:29 2019-11-16 04:35 -11.2084 133.4407
    CTD Cast [details]   Cast 167 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 04:57 2019-11-16 05:05 -11.2087 133.4406
    CTD Cast [details]   Cast 168 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 05:28 2019-11-16 05:35 -11.2106 133.4401
    CTD Cast [details]   Cast 169 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 05:59 2019-11-16 06:05 -11.2103 133.4389
    CTD Cast [details]   Cast 170 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 06:29 2019-11-16 06:35 -11.2099 133.4387
    CTD Cast [details]   Cast 171 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 06:59 2019-11-16 07:10 -11.2111 133.4395
    CTD Cast [details]   Cast 172 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 07:29 2019-11-16 07:34 -11.2116 133.4402
    CTD Cast [details]   Cast 173 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 08:00 2019-11-16 08:05 -11.2114 133.4388
    CTD Cast [details]   Cast 174 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 08:27 2019-11-16 08:35 -11.2112 133.4374
    CTD Cast [details]   Cast 175 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 08:59 2019-11-16 09:05 -11.2111 133.4372
    CTD Cast [details]   Cast 176 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 09:29 2019-11-16 09:35 -11.2111 133.4370
    CTD Cast [details]   Cast 177 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 09:58 2019-11-16 10:05 -11.2111 133.4383
    CTD Cast [details]   Cast 178 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 10:29 2019-11-16 10:35 -11.2110 133.4399
    CTD Cast [details]   Cast 179 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 10:59 2019-11-16 11:09 -11.2111 133.4416
    CTD Cast [details]   Cast 180 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 11:29 2019-11-16 11:35 -11.2120 133.4405
    CTD Cast [details]   Cast 181 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 11:59 2019-11-16 12:04 -11.2131 133.4393
    CTD Cast [details]   Cast 182 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 12:29 2019-11-16 12:35 -11.2133 133.4388
    CTD Cast [details]   Cast 183 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 12:59 2019-11-16 13:06 -11.2137 133.4381
    CTD Cast [details]   Cast 184 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 13:29 2019-11-16 13:35 -11.2140 133.4370
    CTD Cast [details]   Cast 185 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 14:00 2019-11-16 14:08 -11.2136 133.4359
    CTD Cast [details]   Cast 186 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 14:27 2019-11-16 14:35 -11.2127 133.4344
    CTD Cast [details]   Cast 187 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 14:59 2019-11-16 15:05 -11.2109 133.4330
    CTD Cast [details]   Cast 188 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 15:29 2019-11-16 15:35 -11.2085 133.4312
    CTD Cast [details]   Cast 189 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 15:59 2019-11-16 16:04 -11.2074 133.4308
    CTD Cast [details]   Cast 190 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 16:29 2019-11-16 16:34 -11.2062 133.4305
    CTD Cast [details]   Cast 191 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 17:00 2019-11-16 17:06 -11.2055 133.4303
    CTD Cast [details]   Cast 192 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 17:29 2019-11-16 17:35 -11.2055 133.4303
    CTD Cast [details]   Cast 193 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 18:01 2019-11-16 18:07 -11.2070 133.4307
    CTD Cast [details]   Cast 194 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 18:29 2019-11-16 18:35 -11.2084 133.4317
    CTD Cast [details]   Cast 195 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 18:59 2019-11-16 19:05 -11.2096 133.4328
    CTD Cast [details]   Cast 196 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 19:29 2019-11-16 19:34 -11.2097 133.4327
    CTD Cast [details]   Cast 197 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 19:59 2019-11-16 20:04 -11.2089 133.4326
    CTD Cast [details]   Cast 198 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 20:29 2019-11-16 20:34 -11.2087 133.4328
    CTD Cast [details]   Cast 199 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 20:59 2019-11-16 21:04 -11.2086 133.4329
    CTD Cast / Hydrology [details]   Cast 200 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-16 21:30 2019-11-16 21:38 -11.2081 133.4334
    CTD Cast / Hydrology [details]   Cast 201 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-17 04:30 2019-11-17 04:47 -11.2237 133.0269
    CTD Cast / Hydrology [details]   Cast 202 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-17 17:02 2019-11-17 17:14 -11.2280 133.0230
    CTD Cast / Hydrology [details]   Cast 203 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-19 01:33 2019-11-19 01:38 -12.0939 130.6266
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-19 01:51 610.3
    CTD Cast [details]   Cast 204 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 19:30 2019-11-22 19:36 -12.3118 130.4016
    CTD Cast [details]   Cast 205 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 19:59 2019-11-22 20:03 -12.3116 130.4014
    CTD Cast [details]   Cast 206 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 20:29 2019-11-22 20:34 -12.3098 130.3995
    CTD Cast [details]   Cast 207 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 21:00 2019-11-22 21:04 -12.3069 130.3991
    CTD Cast [details]   Cast 208 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 21:29 2019-11-22 21:33 -12.3069 130.3991
    CTD Cast [details]   Cast 209 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 22:00 2019-11-22 22:04 -12.3098 130.4012
    CTD Cast [details]   Cast 210 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 22:29 2019-11-22 22:33 -12.3100 130.4011
    CTD Cast [details]   Cast 211 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 23:00 2019-11-22 23:03 -12.3105 130.4007
    CTD Cast [details]   Cast 212 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-22 23:30 2019-11-22 23:34 -12.3110 130.4004
    CTD Cast [details]   Cast 213 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 00:00 2019-11-23 00:03 -12.3114 130.4002
    CTD Cast [details]   Cast 214 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 00:30 2019-11-23 00:33 -12.3123 130.3999
    CTD Cast [details]   Cast 215 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 01:00 2019-11-23 01:03 -12.3138 130.4002
    CTD Cast [details]   Cast 216 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 01:30 2019-11-23 01:34 -12.3152 130.4027
    CTD Cast [details]   Cast 217 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 02:00 2019-11-23 02:04 -12.3147 130.4039
    CTD Cast [details]   Cast 218 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 02:30 2019-11-23 02:34 -12.3141 130.4045
    CTD Cast [details]   Cast 219 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 03:00 2019-11-23 03:04 -12.3137 130.4047
    CTD Cast [details]   Cast 220 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 03:30 2019-11-23 03:34 -12.3139 130.4046
    CTD Cast [details]   Cast 221 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 04:00 2019-11-23 04:04 -12.3140 130.4046
    CTD Cast [details]   Cast 222 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 04:30 2019-11-23 04:34 -12.3135 130.4048
    CTD Cast [details]   Cast 223 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 05:00 2019-11-23 05:04 -12.3128 130.4051
    CTD Cast [details]   Cast 224 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 05:30 2019-11-23 05:34 -12.3128 130.4051
    CTD Cast [details]   Cast 225 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 06:00 2019-11-23 06:04 -12.3123 130.4052
    CTD Cast [details]   Cast 226 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 06:31 2019-11-23 06:35 -12.3123 130.4052
    CTD Cast [details]   Cast 227 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 07:01 2019-11-23 07:05 -12.3117 130.4053
    CTD Cast [details]   Cast 228 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 07:30 2019-11-23 07:34 -12.3131 130.4052
    CTD Cast [details]   Cast 229 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 08:00 2019-11-23 08:04 -12.3155 130.4050
    CTD Cast [details]   Cast 230 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 08:30 2019-11-23 08:35 -12.3166 130.4051
    CTD Cast [details]   Cast 231 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 09:00 2019-11-23 09:04 -12.3153 130.4056
    CTD Cast [details]   Cast 232 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 09:30 2019-11-23 09:34 -12.3161 130.4053
    CTD Cast [details]   Cast 233 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 10:00 2019-11-23 10:04 -12.3160 130.4053
    CTD Cast [details]   Cast 234 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 10:31 2019-11-23 10:35 -12.3151 130.4056
    CTD Cast [details]   Cast 235 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 11:01 2019-11-23 11:05 -12.3153 130.4056
    CTD Cast [details]   Cast 236 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 11:30 2019-11-23 11:33 -12.3167 130.4050
    CTD Cast [details]   Cast 237 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 12:00 2019-11-23 12:05 -12.3173 130.4044
    CTD Cast [details]   Cast 238 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 12:29 2019-11-23 12:33 -12.3163 130.4017
    CTD Cast [details]   Cast 239 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 12:59 2019-11-23 13:04 -12.3173 130.4022
    CTD Cast [details]   Cast 240 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 13:31 2019-11-23 13:35 -12.3186 130.4026
    CTD Cast [details]   Cast 241 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 14:00 2019-11-23 14:04 -12.3189 130.4029
    CTD Cast [details]   Cast 242 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 14:30 2019-11-23 14:34 -12.3193 130.4043
    CTD Cast [details]   Cast 243 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 15:00 2019-11-23 15:04 -12.3187 130.4068
    CTD Cast [details]   Cast 244 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 15:31 2019-11-23 15:35 -12.3171 130.4086
    CTD Cast [details]   Cast 245 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 16:01 2019-11-23 16:05 -12.3157 130.4092
    CTD Cast [details]   Cast 246 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 16:31 2019-11-23 16:34 -12.3146 130.4095
    CTD Cast [details]   Cast 247 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 16:59 2019-11-23 17:03 -12.3142 130.4095
    CTD Cast [details]   Cast 248 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 17:30 2019-11-23 17:33 -12.3133 130.4096
    CTD Cast [details]   Cast 249 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 17:59 2019-11-23 18:03 -12.3120 130.4097
    CTD Cast [details]   Cast 250 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 18:30 2019-11-23 18:34 -12.3114 130.4095
    CTD Cast [details]   Cast 251 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 19:00 2019-11-23 19:04 -12.3097 130.4089
    CTD Cast [details]   Cast 252 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 19:29 2019-11-23 19:33 -12.3085 130.4078
    CTD Cast [details]   Cast 253 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 19:58 2019-11-23 20:02 -12.3068 130.4031
    CTD Cast [details]   Cast 254 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 20:29 2019-11-23 20:34 -12.3063 130.3996
    CTD Cast [details]   Cast 255 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 20:59 2019-11-23 21:04 -12.3068 130.3988
    CTD Cast [details]   Cast 256 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 21:29 2019-11-23 21:34 -12.3078 130.3973
    CTD Cast [details]   Cast 257 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 22:05 2019-11-23 22:09 -12.3083 130.3966
    CTD Cast [details]   Cast 258 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 22:29 2019-11-23 22:33 -12.3092 130.3952
    CTD Cast [details]   Cast 259 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 22:55 2019-11-23 23:03 -12.3101 130.3943
    CTD Cast [details]   Cast 260 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 23:30 2019-11-23 23:33 -12.3109 130.3938
    CTD Cast [details]   Cast 261 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-23 23:59 2019-11-24 00:03 -12.3115 130.3936
    CTD Cast [details]   Cast 262 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 00:30 2019-11-24 00:34 -12.3123 130.3934
    CTD Cast [details]   Cast 263 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 00:59 2019-11-24 01:03 -12.3127 130.3933
    CTD Cast [details]   Cast 264 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 01:30 2019-11-24 01:34 -12.3133 130.3933
    CTD Cast [details]   Cast 265 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 02:01 2019-11-24 02:05 -12.3150 130.3942
    CTD Cast [details]   Cast 266 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 02:29 2019-11-24 02:33 -12.3147 130.3977
    CTD Cast [details]   Cast 267 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 03:00 2019-11-24 03:04 -12.3155 130.3978
    CTD Cast [details]   Cast 268 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 03:30 2019-11-24 03:34 -12.3175 130.3981
    CTD Cast [details]   Cast 269 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 03:59 2019-11-24 04:04 -12.3178 130.3982
    CTD Cast [details]   Cast 270 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 04:30 2019-11-24 04:35 -12.3172 130.3983
    CTD Cast [details]   Cast 271 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 05:01 2019-11-24 05:05 -12.3162 130.3985
    CTD Cast [details]   Cast 272 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 05:32 2019-11-24 05:36 -12.3162 130.3985
    CTD Cast [details]   Cast 273 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 06:05 2019-11-24 06:09 -12.3160 130.3985
    CTD Cast [details]   Cast 274 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 06:30 2019-11-24 06:35 -12.3154 130.3986
    CTD Cast [details]   Cast 275 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 06:59 2019-11-24 07:04 -12.3143 130.3987
    CTD Cast [details]   Cast 276 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 07:29 2019-11-24 07:34 -12.3129 130.3988
    CTD Cast [details]   Cast 277 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 07:59 2019-11-24 08:04 -12.3127 130.3987
    CTD Cast [details]   Cast 278 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 08:30 2019-11-24 08:34 -12.3121 130.3984
    CTD Cast [details]   Cast 279 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 09:00 2019-11-24 09:04 -12.3118 130.3983
    CTD Cast [details]   Cast 280 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 09:29 2019-11-24 09:34 -12.3108 130.3979
    CTD Cast [details]   Cast 281 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 09:59 2019-11-24 10:04 -12.3088 130.3969
    CTD Cast [details]   Cast 282 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 10:29 2019-11-24 10:34 -12.3066 130.3954
    CTD Cast [details]   Cast 283 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 10:59 2019-11-24 11:05 -12.3051 130.3948
    CTD Cast [details]   Cast 284 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 11:30 2019-11-24 11:34 -12.3028 130.3930
    CTD Cast [details]   Cast 285 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 11:59 2019-11-24 12:04 -12.3038 130.3919
    CTD Cast [details]   Cast 286 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 12:30 2019-11-24 12:34 -12.3038 130.3919
    CTD Cast [details]   Cast 287 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 13:00 2019-11-24 13:04 -12.3036 130.3919
    CTD Cast [details]   Cast 288 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 19:33 2019-11-24 19:37 -12.2982 130.3940
    CTD Cast [details]   Cast 289 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 20:03 2019-11-24 20:07 -12.2974 130.3935
    CTD Cast [details]   Cast 290 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 20:30 2019-11-24 20:35 -12.2958 130.3925
    CTD Cast [details]   Cast 291 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 21:00 2019-11-24 21:04 -12.2925 130.3906
    CTD Cast / Hydrology [details]   Cast 292 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-24 21:30 2019-11-24 21:40 -12.2875 130.3877
    CTD Cast / Hydrology [details]   Cast 293 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-25 00:08 2019-11-25 00:14 -12.2835 130.2855
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-27 03:41 336
    CTD Cast / Hydrology [details]   Cast 294 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-27 07:23 2019-11-27 07:33 -11.2195 133.0471
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-27 09:45 279.6
    CTD Cast / Hydrology [details]   Cast 295 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-27 16:30 2019-11-27 16:44 -11.2202 133.0473
    CTD Cast / Hydrology [details]   Cast 296 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-28 01:36 2019-11-28 01:50 -11.2132 133.0450
    CTD Cast / Hydrology [details]   Cast 297 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-11-29 01:39 2019-11-29 01:46 -12.0783 130.9041
    XBT Cast [details]   Sippican Deep Blue 2548 2019-11-29 03:07 286.8
    CTD Cast [details]   Cast 298 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-02 01:20 2019-12-02 01:24 -12.3101 130.4103
    CTD Cast [details]   Cast 299 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 19:52 2019-12-03 19:55 -12.3203 130.4135
    CTD Cast [details]   Cast 300 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 20:30 2019-12-03 20:33 -12.3212 130.4159
    CTD Cast [details]   Cast 301 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 20:59 2019-12-03 21:03 -12.3205 130.4163
    CTD Cast [details]   Cast 302 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 21:29 2019-12-03 21:32 -12.3155 130.4148
    CTD Cast [details]   Cast 303 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 21:59 2019-12-03 22:02 -12.3116 130.4120
    CTD Cast [details]   Cast 304 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 22:31 2019-12-03 22:34 -12.3115 130.4121
    CTD Cast [details]   Cast 305 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 22:58 2019-12-03 23:01 -12.3115 130.4121
    CTD Cast [details]   Cast 306 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 23:29 2019-12-03 23:33 -12.3112 130.4122
    CTD Cast [details]   Cast 307 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-03 23:58 2019-12-04 00:02 -12.3110 130.4123
    CTD Cast [details]   Cast 308 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 00:32 2019-12-04 00:36 -12.3112 130.4123
    CTD Cast [details]   Cast 309 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 00:58 2019-12-04 01:02 -12.3116 130.4123
    CTD Cast [details]   Cast 310 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 01:30 2019-12-04 01:34 -12.3122 130.4119
    CTD Cast [details]   Cast 311 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 01:58 2019-12-04 02:01 -12.3112 130.4106
    CTD Cast [details]   Cast 312 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 02:30 2019-12-04 02:34 -12.3111 130.4103
    CTD Cast [details]   Cast 313 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 03:00 2019-12-04 03:03 -12.3111 130.4103
    CTD Cast [details]   Cast 314 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 03:30 2019-12-04 03:33 -12.3114 130.4104
    CTD Cast [details]   Cast 315 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 03:59 2019-12-04 04:03 -12.3117 130.4105
    CTD Cast [details]   Cast 316 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 04:29 2019-12-04 04:33 -12.3122 130.4106
    CTD Cast [details]   Cast 317 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 04:59 2019-12-04 05:03 -12.3125 130.4106
    CTD Cast [details]   Cast 318 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 05:29 2019-12-04 05:33 -12.3128 130.4107
    CTD Cast [details]   Cast 319 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 05:59 2019-12-04 06:03 -12.3127 130.4107
    CTD Cast [details]   Cast 320 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 06:29 2019-12-04 06:33 -12.3131 130.4108
    CTD Cast [details]   Cast 321 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 07:00 2019-12-04 07:07 -12.3132 130.4109
    CTD Cast [details]   Cast 322 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 07:29 2019-12-04 07:33 -12.3128 130.4116
    CTD Cast [details]   Cast 323 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 08:00 2019-12-04 08:04 -12.3119 130.4121
    CTD Cast [details]   Cast 324 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 08:30 2019-12-04 08:33 -12.3126 130.4124
    CTD Cast [details]   Cast 325 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 09:00 2019-12-04 09:03 -12.3124 130.4124
    CTD Cast [details]   Cast 326 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 09:30 2019-12-04 09:33 -12.3141 130.4126
    CTD Cast [details]   Cast 327 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 10:00 2019-12-04 10:04 -12.3143 130.4126
    CTD Cast [details]   Cast 328 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 10:29 2019-12-04 10:33 -12.3144 130.4126
    CTD Cast [details]   Cast 329 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 10:59 2019-12-04 11:03 -12.3141 130.4128
    CTD Cast [details]   Cast 330 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 11:30 2019-12-04 11:34 -12.3141 130.4128
    CTD Cast [details]   Cast 331 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 11:59 2019-12-04 12:03 -12.3136 130.4128
    CTD Cast [details]   Cast 332 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 12:31 2019-12-04 12:35 -12.3127 130.4130
    CTD Cast [details]   Cast 333 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 13:00 2019-12-04 13:04 -12.3119 130.4130
    CTD Cast [details]   Cast 334 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 13:29 2019-12-04 13:34 -12.3111 130.4131
    CTD Cast [details]   Cast 335 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 13:59 2019-12-04 14:03 -12.3104 130.4132
    CTD Cast [details]   Cast 336 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 14:28 2019-12-04 14:32 -12.3097 130.4132
    CTD Cast [details]   Cast 337 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 14:58 2019-12-04 15:02 -12.3092 130.4131
    CTD Cast [details]   Cast 338 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 15:28 2019-12-04 15:31 -12.3095 130.4131
    CTD Cast [details]   Cast 339 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 15:59 2019-12-04 16:02 -12.3105 130.4132
    CTD Cast [details]   Cast 340 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 16:28 2019-12-04 16:32 -12.3117 130.4133
    CTD Cast [details]   Cast 341 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 16:58 2019-12-04 17:02 -12.3107 130.4135
    CTD Cast [details]   Cast 342 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 17:28 2019-12-04 17:32 -12.3114 130.4135
    CTD Cast [details]   Cast 343 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 17:58 2019-12-04 18:02 -12.3120 130.4134
    CTD Cast [details]   Cast 344 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 18:28 2019-12-04 18:32 -12.3124 130.4132
    CTD Cast [details]   Cast 345 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 18:58 2019-12-04 19:02 -12.3132 130.4130
    CTD Cast [details]   Cast 346 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 19:28 2019-12-04 19:31 -12.3138 130.4122
    CTD Cast [details]   Cast 347 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 19:58 2019-12-04 20:01 -12.3138 130.4118
    CTD Cast [details]   Cast 348 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 20:28 2019-12-04 20:31 -12.3139 130.4123
    CTD Cast [details]   Cast 349 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 20:58 2019-12-04 21:01 -12.3140 130.4133
    CTD Cast [details]   Cast 350 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 21:28 2019-12-04 21:31 -12.3138 130.4148
    CTD Cast [details]   Cast 351 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 21:58 2019-12-04 22:01 -12.3132 130.4156
    CTD Cast [details]   Cast 352 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 22:28 2019-12-04 22:32 -12.3143 130.4161
    CTD Cast [details]   Cast 353 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 22:59 2019-12-04 23:03 -12.3144 130.4163
    CTD Cast [details]   Cast 354 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 23:29 2019-12-04 23:33 -12.3141 130.4163
    CTD Cast [details]   Cast 355 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-04 23:58 2019-12-05 00:02 -12.3127 130.4163
    CTD Cast [details]   Cast 356 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 00:28 2019-12-05 00:32 -12.3126 130.4163
    CTD Cast [details]   Cast 357 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 00:58 2019-12-05 01:02 -12.3126 130.4163
    CTD Cast [details]   Cast 358 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 01:28 2019-12-05 01:32 -12.3117 130.4163
    CTD Cast [details]   Cast 359 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 01:58 2019-12-05 02:02 -12.3114 130.4162
    CTD Cast [details]   Cast 360 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 02:30 2019-12-05 02:34 -12.3108 130.4161
    CTD Cast [details]   Cast 361 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 03:00 2019-12-05 03:04 -12.3093 130.4157
    CTD Cast [details]   Cast 362 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 03:31 2019-12-05 03:34 -12.3084 130.4154
    CTD Cast [details]   Cast 363 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 04:00 2019-12-05 04:04 -12.3084 130.4154
    CTD Cast [details]   Cast 364 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 04:30 2019-12-05 04:35 -12.3084 130.4154
    CTD Cast [details]   Cast 365 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 05:00 2019-12-05 05:04 -12.3090 130.4158
    CTD Cast [details]   Cast 366 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 05:30 2019-12-05 05:33 -12.3091 130.4159
    CTD Cast [details]   Cast 367 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 06:00 2019-12-05 06:03 -12.3098 130.4163
    CTD Cast [details]   Cast 368 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 06:29 2019-12-05 06:33 -12.3095 130.4162
    CTD Cast [details]   Cast 369 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 07:00 2019-12-05 07:04 -12.3085 130.4159
    CTD Cast [details]   Cast 370 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 07:30 2019-12-05 07:34 -12.3088 130.4160
    CTD Cast [details]   Cast 371 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 07:59 2019-12-05 08:03 -12.3087 130.4160
    CTD Cast [details]   Cast 372 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 08:29 2019-12-05 08:34 -12.3085 130.4159
    CTD Cast [details]   Cast 373 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 08:59 2019-12-05 09:03 -12.3080 130.4156
    CTD Cast [details]   Cast 374 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 09:30 2019-12-05 09:37 -12.3085 130.4159
    CTD Cast [details]   Cast 375 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 10:00 2019-12-05 10:04 -12.3096 130.4165
    CTD Cast [details]   Cast 376 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 10:30 2019-12-05 10:34 -12.3107 130.4169
    CTD Cast [details]   Cast 377 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 11:00 2019-12-05 11:04 -12.3113 130.4172
    CTD Cast [details]   Cast 378 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 11:30 2019-12-05 11:34 -12.3103 130.4171
    CTD Cast [details]   Cast 379 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 12:01 2019-12-05 12:04 -12.3096 130.4170
    CTD Cast [details]   Cast 380 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 12:30 2019-12-05 12:34 -12.3106 130.4173
    CTD Cast [details]   Cast 381 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 12:59 2019-12-05 13:03 -12.3102 130.4172
    CTD Cast [details]   Cast 382 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 13:30 2019-12-05 13:34 -12.3102 130.4172
    CTD Cast [details]   Cast 383 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 14:01 2019-12-05 14:04 -12.3108 130.4173
    CTD Cast [details]   Cast 384 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 14:29 2019-12-05 14:34 -12.3110 130.4173
    CTD Cast [details]   Cast 385 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 15:03 2019-12-05 15:07 -12.3098 130.4174
    CTD Cast [details]   Cast 386 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 15:28 2019-12-05 15:32 -12.3102 130.4175
    CTD Cast [details]   Cast 387 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 15:59 2019-12-05 16:03 -12.3093 130.4174
    CTD Cast [details]   Cast 388 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 16:29 2019-12-05 16:33 -12.3072 130.4173
    CTD Cast [details]   Cast 389 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 16:58 2019-12-05 17:02 -12.3078 130.4175
    CTD Cast [details]   Cast 390 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 17:28 2019-12-05 17:31 -12.3082 130.4176
    CTD Cast [details]   Cast 391 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 17:58 2019-12-05 18:01 -12.3087 130.4177
    CTD Cast [details]   Cast 392 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 18:29 2019-12-05 18:33 -12.3084 130.4176
    CTD Cast [details]   Cast 393 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 19:00 2019-12-05 19:03 -12.3065 130.4171
    CTD Cast / Hydrology [details]   Cast 394 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-05 19:27 2019-12-05 19:38 -12.3054 130.4168
    CTD Cast [details]   Cast 395 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-07 06:30 2019-12-07 06:35 -12.3093 130.3818
    CTD Cast / Hydrology [details]   Cast 396 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-07 07:26 2019-12-07 07:37 -12.3055 130.4331
    CTD Cast [details]   Cast 397 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-08 06:47 2019-12-08 06:51 -12.3004 130.4008
    CTD Cast / Hydrology [details]   Cast 398 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-08 07:54 2019-12-08 08:02 -12.3099 130.4482
    CTD Cast / Hydrology [details]   Cast 399 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-10 06:58 2019-12-10 07:06 -12.3070 130.4205
    CTD Cast [details]   Cast 400 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 10:32 2019-12-11 10:38 -12.3136 130.2773
    CTD Cast [details]   Cast 401 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 11:08 2019-12-11 11:12 -12.3123 130.2757
    CTD Cast [details]   Cast 402 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 11:30 2019-12-11 11:34 -12.3125 130.2755
    CTD Cast [details]   Cast 403 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 11:59 2019-12-11 12:03 -12.3130 130.2751
    CTD Cast [details]   Cast 404 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 12:28 2019-12-11 12:33 -12.3134 130.2746
    CTD Cast [details]   Cast 405 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 12:57 2019-12-11 13:03 -12.3139 130.2743
    CTD Cast [details]   Cast 406 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-11 13:29 2019-12-11 13:33 -12.3145 130.2738
    CTD Cast [details]   Cast 407 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 09:07 2019-12-12 09:15 -12.3075 130.4153
    CTD Cast [details]   Cast 408 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 15:28 2019-12-12 15:45 -11.6625 129.9014
    CTD Cast / Hydrology [details]   Cast 409 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 16:34 2019-12-12 16:56 -11.6617 129.9039
    CTD Cast [details]   Cast 410 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 17:42 2019-12-12 17:59 -11.6638 129.9023
    CTD Cast [details]   Cast 411 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 18:30 2019-12-12 18:47 -11.6643 129.9021
    CTD Cast [details]   Cast 412 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 19:30 2019-12-12 19:46 -11.6639 129.9033
    CTD Cast [details]   Cast 413 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 20:30 2019-12-12 20:46 -11.6635 129.9038
    CTD Cast / Hydrology [details]   Cast 414 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 21:30 2019-12-12 21:54 -11.6610 129.9035
    CTD Cast [details]   Cast 415 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 22:31 2019-12-12 22:47 -11.6607 129.9048
    CTD Cast [details]   Cast 416 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-12 23:37 2019-12-12 23:56 -11.6498 129.9058
    CTD Cast / Hydrology [details]   Cast 417 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-13 00:30 2019-12-13 00:54 -11.6612 129.9024
    XBT Cast [details]   Sippican Deep Blue 2548 2019-12-13 01:10 571.4
    CTD Cast [details]   Cast 418 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-13 09:32 2019-12-13 09:36 -12.3076 130.4271
    CTD Cast [details]   Cast 419 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-13 10:00 2019-12-13 10:05 -12.3093 130.4305
    CTD Cast / Hydrology [details]   Cast 420 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-13 10:29 2019-12-13 10:35 -12.3090 130.4303
    XBT Cast [details]   Sippican Deep Blue 2548 2019-12-13 14:26 460.5
    CTD Cast [details]   Cast 421 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-14 01:49 2019-12-14 01:52 -12.3115 130.4192
    CTD Cast [details]   Cast 422 CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-14 02:13 2019-12-14 02:16 -12.3097 130.4111
    CTD Cast / Hydrology [details]   Cast 423 Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR 2019-12-14 02:44 2019-12-14 02:55 -12.3105 130.4098

    Save this list as

    NCMI Information and Data Centre  »  Applications  »  Data Trawler