Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 73
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-11-06 03:30 to 2019-11-06 04:16 UTC
Where: 13° 47.8' S 121° 57.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
24 | 5.2 | 201.91 | 34.570 | 0.05 | 29.90 | 0.08 | 0.04 | < 0.02 | 2.08 |
23 | 40.2 | 216.07 | 34.456 | 0.05 | 27.61 | 0.08 | < 0.02 | < 0.02 | 2.29 |
22 | 44.9 | 217.50 | 34.443 | 0.05 | 27.47 | 0.07 | < 0.02 | < 0.02 | 2.31 |
21 | 50.3 | 218.21 | 34.462 | 0.05 | 27.24 | 0.08 | < 0.02 | < 0.02 | 2.44 |
20 | 56.4 | 216.25 | 34.481 | 0.05 | 27.14 | 0.09 | < 0.02 | < 0.02 | 2.59 |
19 | 60 | 214.46 | 34.499 | 0.05 | 26.78 | 0.10 | 0.02 | < 0.02 | 2.77 |
18 | 65.7 | < 0.02 | < 0.02 | < 0.02 | 26.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 65.9 | 212.94 | 34.517 | 0.05 | 26.53 | 0.10 | < 0.02 | < 0.02 | 2.96 |
16 | 70.2 | 210.40 | 34.523 | 0.08 | 26.22 | 0.12 | 0.17 | < 0.02 | 3.05 |
15 | 75.6 | 208.66 | 34.532 | 0.13 | 26.04 | 0.13 | < 0.02 | < 0.02 | 3.20 |
14 | 80.8 | 203.52 | 34.553 | 0.60 | 25.81 | 0.16 | 0.02 | 0.04 | 3.75 |
13 | 85.4 | 179.72 | 34.561 | 3.94 | 24.73 | 0.39 | < 0.02 | 0.18 | 6.53 |
12 | 90.3 | 153.81 | 34.506 | 8.23 | 23.40 | 0.65 | < 0.02 | 0.10 | 10.52 |
11 | 95.7 | < 0.02 | < 0.02 | < 0.02 | 22.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 95.7 | 142.47 | 34.499 | 10.04 | 22.34 | 0.76 | < 0.02 | 0.06 | 12.59 |
9 | 100.2 | 142.02 | 34.516 | 10.13 | 22.23 | 0.76 | < 0.02 | 0.05 | 12.76 |
8 | 105.1 | 140.77 | 34.523 | 10.35 | 22.19 | 0.78 | < 0.02 | 0.05 | 13.01 |
7 | 110.8 | 138.32 | 34.531 | 10.79 | 21.90 | 0.81 | < 0.02 | 0.04 | 13.51 |
6 | 115.8 | 135.46 | 34.546 | 11.36 | 21.65 | 0.85 | < 0.02 | 0.03 | 14.31 |
5 | 120.3 | 131.93 | 34.606 | 12.37 | 21.40 | 0.93 | < 0.02 | 0.03 | 16.32 |
4 | 250.1 | 103.57 | 34.566 | 26.47 | 11.68 | 1.87 | < 0.02 | < 0.02 | 42.08 |
2 | 350.8 | 97.94 | 34.570 | 30.21 | 9.45 | 2.12 | < 0.02 | < 0.02 | 53.26 |
3 | 350.8 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 530.8 | 94.32 | 34.584 | 32.49 | 8.12 | 2.30 | < 0.02 | < 0.02 | 63.23 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72089 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4426 | Seabird | SBE4C | 4426 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |