Deployment Details
Survey: - IN2019_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-10-21 07:34 to 2019-10-21 07:51 UTC
Where: 13° 19.4' S 123° 42.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
10 | 5.2 | 206.60 | 34.469 | 0.05 | 30.28 | 0.09 | < 0.02 | < 0.02 | 1.89 |
12 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 30.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 30.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 67.7 | < 0.02 | < 0.02 | < 0.02 | 25.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 67.8 | 183.38 | 34.406 | 3.58 | 25.16 | 0.37 | < 0.02 | 0.11 | 5.37 |
6 | 99.7 | 136.08 | 34.645 | 10.75 | 21.84 | 0.80 | < 0.02 | 0.04 | 12.64 |
7 | 99.8 | < 0.02 | < 0.02 | < 0.02 | 21.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 174.7 | 108.21 | 34.580 | 21.19 | 15.62 | 1.51 | 0.02 | 0.02 | 30.22 |
5 | 174.8 | < 0.02 | < 0.02 | < 0.02 | 15.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 210.5 | 106.20 | 34.565 | 23.00 | 14.06 | 1.64 | 0.05 | 0.02 | 34.05 |
3 | 210.5 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 210.6 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4662 | Seabird | SBE4C | 4662 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 4835 | 1454 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |