Deployment Details
Survey: - IN2019_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4662,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 24 - SN 6130,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-10-21 15:45 to 2019-10-21 16:16 UTC
Where: 13° 29.9' S 122° 30.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
15 | 5 | 207.50 | 34.389 | 0.04 | 28.68 | 0.09 | < 0.02 | < 0.02 | 1.58 |
16 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 28.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 25 | < 0.02 | < 0.02 | < 0.02 | 26.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 25.1 | 211.92 | 34.358 | 0.17 | 26.74 | 0.11 | < 0.02 | 0.03 | 2.19 |
10 | 37.1 | 205.62 | 34.381 | 0.72 | 26.21 | 0.16 | 0.02 | 0.11 | 2.75 |
11 | 37.1 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 37.2 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 61.7 | < 0.02 | < 0.02 | < 0.02 | 25.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 61.7 | 194.41 | 34.405 | 2.14 | 25.24 | 0.26 | < 0.02 | 0.27 | 3.97 |
7 | 61.8 | < 0.02 | < 0.02 | < 0.02 | 25.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 201.9 | 105.89 | 34.580 | 22.60 | 13.85 | 1.60 | < 0.02 | < 0.02 | 32.90 |
4 | 350.4 | 96.69 | 34.569 | 30.17 | 9.42 | 2.15 | < 0.02 | < 0.02 | 54.32 |
5 | 350.5 | < 0.02 | < 0.02 | < 0.02 | 9.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 441.2 | 98.79 | 34.581 | 31.30 | 8.75 | 2.23 | < 0.02 | < 0.02 | 58.42 |
2 | 441.3 | < 0.02 | < 0.02 | < 0.02 | 8.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 441.4 | < 0.02 | < 0.02 | < 0.02 | 8.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4662 | Seabird | SBE4C | 4662 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 4835 | 1454 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |