Deployment Details
Survey: - IN2019_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 294
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4426,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3159,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-11-27 07:23 to 2019-11-27 07:33 UTC
Where: 11° 13.2' S 133° 02.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
24 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 30.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 3.1 | 203.34 | 34.505 | < 0.02 | 30.95 | 0.11 | 0.04 | < 0.02 | 1.49 |
14 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 20 | 190.26 | 34.454 | 0.04 | 30.01 | 0.21 | 0.03 | 0.07 | 1.53 |
18 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 20 | < 0.02 | < 0.02 | < 0.02 | 30.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 30 | < 0.02 | < 0.02 | < 0.02 | 29.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 30 | 188.51 | 34.454 | 0.05 | 29.99 | 0.22 | 0.06 | 0.07 | 1.59 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72089 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4426 | Seabird | SBE4C | 4426 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |