Please login if you have access to particular applications.
Search for events by voyage, equipment, action or within comments.
Event count for each voyage, equipment or action is shown in ().
Caveat: this event log was authored on the voyage using either a standalone logging system called ELOG or more recently an inhouse event logging tool called Everlog. For this reason, some positions are unknown and may be resolved using the logged time and the underway dataset for the voyage.
Events ordered by start time:- Click on column header to sort. Use link on 'When' to see full details. Use the CSV button at the bottom to export data.
Survey | When (UTC) | Latitude | Longitude | Instrument | Identifier | Action | Log | Subject / Comments |
---|---|---|---|---|---|---|---|---|
IN2019_T03 | 2019-12-22 01:29 [view ] | -12.4718 | 130.8468 | Metstation | calibration | in2019_t03 | Starboard wind cal change Starboard RM Young Windspeed m value found to be 0.0999227. Changed to correct value of 0.099227. Starboard RM Young Azimuth c value found to be 0.17188. Changed to correct value of 0.71788. | |
IN2019_T03 | 2019-12-22 20:16 [view ] | -12.4718 | 130.8468 | Gravity Meter [view] | Other | GSM_in2019_t03 | Gravity still reading at Darwin prior to departure Gravity meter was turned on and allowed to settle out on the 22-12-2019 On 23-12-2019 readings as follows: ST = 8265.2, Grav = 8265.3 taken at 0545 (local). | |
IN2019_T03 | 2019-12-22 20:41 [view ] | -12.4718 | 130.8468 | POSMV [view] | Start | GSM_in2019_t03 | PosMV ethernet & USB logging started (~2hrs prior to departure). | |
IN2019_T03 | 2019-12-22 21:12 [view ] | -12.4718 | 130.8468 | Techsas1 [view] | Start | in2019_t03 | Techsas1&2 started | |
IN2019_T03 | 2019-12-22 21:23 [view ] | -12.4718 | 130.8468 | Underway Merger | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-22 22:30 [view ] | -12.4718 | 130.8468 | Radon Detector [view] | Maintenance | in2019_t03_Atmospherics | Started Calibration | |
IN2019_T03 | 2019-12-22 22:37 [view ] | -12.4718 | 130.8468 | Oxygen Optode | Maintenance | in2019_t03 | Sensor replaced New Oxygen Optode sensor installed, SN: 4835 | |
IN2019_T03 | 2019-12-22 22:53 [view ] | -12.4718 | 130.8468 | Other [view] | GSM_in2019_t03 | Departed Wharf - Commence voyage | ||
IN2019_T03 | 2019-12-22 23:00 [view ] | -12.4730 | 130.8468 | AML | GSM_in2019_t03 | Drop keels flush with hull (0m) | ||
IN2019_T03 | 2019-12-22 23:03 [view ] | -12.4740 | 130.8455 | SBP [view] | Start | GSM_in2019_t03 | Start logging SBP Ricker pulse, -25dB, bandpass filter | |
IN2019_T03 | 2019-12-22 23:09 [view ] | -12.4762 | 130.8383 | EM710 [view] | Start | GSM_in2019_t03 | Started logging EM710 svp: IN2019_V06_rtofs_018_edit.asvp | |
IN2019_T03 | 2019-12-22 23:09 [view ] | -12.4762 | 130.8383 | EK60 [view] | Start | GSM_in2019_t03 | Started logging ek60 | |
IN2019_T03 | 2019-12-22 23:09 [view ] | -12.4762 | 130.8383 | SBP [view] | Start | GSM_in2019_t03 | Started logging SBP | |
IN2019_T03 | 2019-12-23 01:00 [view ] | -12.2883 | 130.5485 | Drop Keels [view] | Change | in2019_t03 | Stbd drop keel lowered to flush with gondola | |
IN2019_T03 | 2019-12-23 01:08 [view ] | -12.2888 | 130.5232 | CPC 3772 [view] | Maintenance | in2019_t03_Atmospherics | Restarted Logger script. | |
IN2019_T03 | 2019-12-23 01:34 [view ] | -12.2892 | 130.4437 | Other [view] | Other | GSM_in2019_t03 | Drop keels: Port = flush with Gondola (1.19m), Stbd = Flush with hull (0m) | |
IN2019_T03 | 2019-12-23 01:36 [view ] | -12.2892 | 130.4373 | ADCP [view] | Start | in2019_t03 | ADCP recording started | |
IN2019_T03 | 2019-12-23 01:40 [view ] | -12.2893 | 130.4230 | Instrumentation Clean Seawater Pump [view] | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-23 01:40 [view ] | -12.2893 | 130.4227 | SBP [view] | Power | GSM_in2019_t03 | Pwr set to -15dB & TVG adjusted | |
IN2019_T03 | 2019-12-23 01:41 [view ] | -12.2893 | 130.4217 | TSG [view] | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-23 01:41 [view ] | -12.2893 | 130.4208 | Fluorometer [view] | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-23 01:41 [view ] | -12.2895 | 130.4200 | pCO2 [view] | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-23 01:50 [view ] | -12.2923 | 130.3918 | SBP [view] | Power | GSM_in2019_t03 | Pwr set to -12dB for improved bottom tracking | |
IN2019_T03 | 2019-12-23 02:06 [view ] | -12.2965 | 130.3675 | CPR [view] | cassette 1 deploy | Deployed | in2019_t03 | |
IN2019_T03 | 2019-12-23 02:21 [view ] | -12.3032 | 130.3293 | Stabilised Platform | Start | in2019_t03_Atmospherics | ||
IN2019_T03 | 2019-12-23 03:17 [view ] | -12.3308 | 130.1690 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_WOA13_20191223_001_edit.asvp applied | |
IN2019_T03 | 2019-12-23 05:09 [view ] | -12.3872 | 129.8425 | Stabilized platform | Change | in2019_t03 | Switched platform to 3D wind profiler mode at 0509 LT | |
IN2019_T03 | 2019-12-23 05:27 [view ] | -12.3948 | 129.7983 | Stabilized platform | Change | in2019_t03 | Switched platform back to 5-point profiler mode at 0527 LT | |
IN2019_T03 | 2019-12-23 06:51 [view ] | -12.4388 | 129.5430 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst002.asvp | |
IN2019_T03 | 2019-12-23 18:13 [view ] | -12.7940 | 127.4218 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_003.asvp applied | |
IN2019_T03 | 2019-12-23 19:47 [view ] | -12.8452 | 127.1157 | POSMV [view] | warning | GSM_in2019_t03 | POSMV Position degraded to Marinestar VBS for several minutes Heading = 260.60, Speed = 11.95kts @1955 returmned to Marinestar G4 | |
IN2019_T03 | 2019-12-23 21:46 [view ] | -12.9123 | 126.7142 | TSG [view] | Maintenance | in2019_t03 | TSG filter cleaned | |
IN2019_T03 | 2019-12-23 21:46 [view ] | -12.9127 | 126.7120 | Fluorometer [view] | Maintenance | in2019_t03 | Fluorometer cleaned | |
IN2019_T03 | 2019-12-23 21:47 [view ] | -12.9128 | 126.7108 | pCO2 [view] | Maintenance | in2019_t03 | pCO2 filter cleaned | |
IN2019_T03 | 2019-12-23 22:49 [view ] | -12.9477 | 126.5025 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_004.asvp applied | |
IN2019_T03 | 2019-12-23 23:15 [view ] | -12.9627 | 126.4132 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-23 23:27 [view ] | -12.9690 | 126.3755 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_005.asvp applied | |
IN2019_T03 | 2019-12-24 01:44 [view ] | -13.0422 | 125.9370 | SBP [view] | Line | GSM_in2019_t03 | New line logged before turn at waypoint | |
IN2019_T03 | 2019-12-24 03:07 [view ] | -13.1812 | 125.7345 | SBP [view] | warning | GSM_in2019_t03 | Chard 8 Chan 3 = Error and Chan 4 = Warning. Rebooting SBP | |
IN2019_T03 | 2019-12-24 04:16 [view ] | -13.2900 | 125.5802 | SBP [view] | Other | GSM_in2019_t03 | SBP restarted several times and is now working again - logging on line_005 Acq window increased to 250m for deeper water (110m) | |
IN2019_T03 | 2019-12-24 04:20 [view ] | -13.2965 | 125.5712 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_006.asvp applied | |
IN2019_T03 | 2019-12-24 05:04 [view ] | -13.3667 | 125.4713 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-24 06:24 [view ] | -13.5055 | 125.2742 | Oxygen Optode | calibration | in2019_t03 | Coefficients updated sensor swapped out at the start of the transit, although didn& 39;t have calibration sheet supplied, actual calibration is applied now | |
IN2019_T03 | 2019-12-24 10:17 [view ] | -13.9375 | 124.6603 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst007.asvp | |
IN2019_T03 | 2019-12-24 10:47 [view ] | -13.9922 | 124.5825 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst008.asvp salinity 35.07 | |
IN2019_T03 | 2019-12-24 11:33 [view ] | -14.0750 | 124.4647 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-24 15:24 [view ] | -14.4857 | 123.8793 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst009.asvp | |
IN2019_T03 | 2019-12-24 17:17 [view ] | -14.6757 | 123.6080 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-24 19:06 [view ] | -14.8722 | 123.3277 | SBP [view] | Power | GSM_in2019_t03 | Changed Power to -13dB. New SBP Line 006. | |
IN2019_T03 | 2019-12-24 20:52 [view ] | -15.0655 | 123.0512 | CPR [view] | Retrieved | in2019_t03 | Cassette 1 recovery | |
IN2019_T03 | 2019-12-24 21:19 [view ] | -15.1130 | 122.9840 | CPR [view] | Deployed | in2019_t03 | cassette two | |
IN2019_T03 | 2019-12-24 21:53 [view ] | -15.1725 | 122.8983 | TSG [view] | Maintenance | in2019_t03 | TSG filter cleaned | |
IN2019_T03 | 2019-12-24 21:53 [view ] | -15.1730 | 122.8977 | Fluorometer [view] | Maintenance | in2019_t03 | Fluorometer cleaned | |
IN2019_T03 | 2019-12-24 21:53 [view ] | -15.1735 | 122.8968 | pCO2 [view] | Maintenance | in2019_t03 | pCO2 filter cleaned | |
IN2019_T03 | 2019-12-24 22:14 [view ] | -15.2115 | 122.8425 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_010.asvp applied | |
IN2019_T03 | 2019-12-24 23:04 [view ] | -15.3018 | 122.7132 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-24 23:14 [view ] | -15.3207 | 122.6862 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-24 23:57 [view ] | -15.3972 | 122.5765 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_011.asvp applied | |
IN2019_T03 | 2019-12-25 00:20 [view ] | -15.4378 | 122.5183 | EZNet [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-25 02:46 [view ] | -15.6965 | 122.1725 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_012.asvp applied | |
IN2019_T03 | 2019-12-25 03:32 [view ] | -15.8147 | 122.1040 | Other [view] | Other | GSM_in2019_t03 | Paused logging for a few minutes in Qinsy to copy project to Helmsman1 | |
IN2019_T03 | 2019-12-25 07:15 [view ] | -16.3915 | 121.7692 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst013.asvp | |
IN2019_T03 | 2019-12-25 07:51 [view ] | -16.4893 | 121.7123 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst014.asvp | |
IN2019_T03 | 2019-12-25 11:16 [view ] | -17.1260 | 121.6853 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-25 12:54 [view ] | -17.4280 | 121.7603 | ADCP [view] | Stop | in2019_t03 | stopped os75 - too shallow for any data | |
IN2019_T03 | 2019-12-25 12:54 [view ] | -17.4303 | 121.7610 | ADCP [view] | Change | in2019_t03 | changed os150 to broadband mode, decreased bin size using reccomendations from Jules Hummond for running adcp in less than 100m of water. use os150 in broadband mode, with bin size of 4m to maximise useful data | |
IN2019_T03 | 2019-12-25 13:40 [view ] | -17.5712 | 121.7865 | Aerosol Manifold Sensor Interface | Outage | in2019_t03_Atmospherics | Air inlet controller reset 0194 locked up inlet controller hasnt been tracking from 25/12/2019 to 13:40UTC to 26/12/2019 08:11 required full power reset | |
IN2019_T03 | 2019-12-25 15:38 [view ] | -17.9193 | 121.8365 | CPR [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-25 15:43 [view ] | -17.9258 | 121.8373 | Other [view] | GSM_in2019_t03 | CPR recovered | ||
IN2019_T03 | 2019-12-25 16:00 [view ] | -17.9440 | 121.8400 | Rapid Cast [view] | Start | GSM_in2019_t03 | Two failed rapidcast attempts- loose line at 7m line out | |
IN2019_T03 | 2019-12-25 16:10 [view ] | -17.9475 | 121.8392 | Other [view] | Start | GSM_in2019_t03 | Ship stationary- Start Radar observations | |
IN2019_T03 | 2019-12-25 16:13 [view ] | -17.9475 | 121.8387 | EM710 [view] | Stop | GSM_in2019_t03 | Stop logging on Radar station | |
IN2019_T03 | 2019-12-25 16:18 [view ] | -17.9475 | 121.8387 | SBP [view] | Stop | GSM_in2019_t03 | Stop logging on station | |
IN2019_T03 | 2019-12-25 17:16 [view ] | -17.9477 | 121.8380 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-25 17:39 [view ] | -17.9483 | 121.8372 | Other [view] | GSM_in2019_t03 | Confirmation of stationary time Confirmed with Joshua (science party) and Bridge that the time on the whiteboard showing a ~04:00 local (Perth) departure is correct. This allows for 3.5hrs of observations. | ||
IN2019_T03 | 2019-12-25 18:55 [view ] | -17.9538 | 121.8320 | Rapid Cast [view] | SVP | GSM_in2019_t03 | Completed a sucessful SVP dip on station off Broome (in2019_t03_rsvp_001) Parameters as follows: On Station (stopped) Used Float, Nominal target = 30m (in wd of 38m), Coverage set to 90% - achieved a cast of 27.8m | |
IN2019_T03 | 2019-12-25 18:58 [view ] | -17.9542 | 121.8318 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_rsvp_001.asvp applied | |
IN2019_T03 | 2019-12-25 19:49 [view ] | -17.9610 | 121.8300 | Metstation | Change | in2019_t03 | Changed Win Azimuth coefficient Changed sign of Wind Azimuth c value, from 0.71788 to -0.71788. | |
IN2019_T03 | 2019-12-25 19:49 [view ] | -17.9615 | 121.8288 | Other [view] | Other | GSM_in2019_t03 | Departed Broome Station at 19:47 (UTC) Time on station = 3h37min | |
IN2019_T03 | 2019-12-25 19:52 [view ] | -17.9647 | 121.8222 | EM710 [view] | Start | GSM_in2019_t03 | Started looging EM710 & Qinsy | |
IN2019_T03 | 2019-12-25 19:52 [view ] | -17.9647 | 121.8222 | SBP [view] | Start | GSM_in2019_t03 | Started looging EM120 | |
IN2019_T03 | 2019-12-25 21:52 [view ] | -18.1430 | 121.4680 | CTD [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-25 21:58 [view ] | -18.1465 | 121.4618 | EM710 [view] | Other | GSM_in2019_t03 | Stopped to conduct CTD in 55m wd. Continued loggng MBES but suspended SBP | |
IN2019_T03 | 2019-12-25 22:02 [view ] | -18.1465 | 121.4618 | Other [view] | GSM_in2019_t03 | CTD launched | ||
IN2019_T03 | 2019-12-25 22:19 [view ] | -18.1463 | 121.4628 | CTD [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-25 22:21 [view ] | -18.1463 | 121.4628 | Other [view] | GSM_in2019_t03 | CTD back on deck | ||
IN2019_T03 | 2019-12-25 22:30 [view ] | -18.1457 | 121.4620 | EZNet [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-25 22:55 [view ] | -18.1507 | 121.4495 | SBP [view] | Start | GSM_in2019_t03 | Restarted SBP logging | |
IN2019_T03 | 2019-12-26 00:00 [view ] | -18.1647 | 121.4232 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_ctd_001.asvp applied SVP dervived from shallow CTD cast. | |
IN2019_T03 | 2019-12-26 02:16 [view ] | -18.1980 | 121.3605 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-26 03:32 [view ] | -18.2255 | 121.3067 | CPR [view] | Deployed | in2019_t03 | Redeployed cassette 2 Segment 41 | |
IN2019_T03 | 2019-12-26 03:40 [view ] | -18.2327 | 121.2932 | Metstation | Change | in2019_t03 | Changed T&RH sensor Lost both port and stbd T&RH sensors and Port 0194 board, last night. Replaced stbd Rotronic T&RH sensor with Vaisala T&RH sensor, SN: H4310110 | |
IN2019_T03 | 2019-12-26 05:16 [view ] | -18.3728 | 121.0222 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-26 06:52 [view ] | -18.5135 | 120.7505 | ADCP [view] | restarted | in2019_t03 | adcp machine restarted due to acquisition appearing to have stopped Acquisition appeared to have stopped some time around 15:21 UTC 26/12/2019 - entire server gui was unresponsive, and webplots last update was at 15:21. Reboot seems to have fixed it. | |
IN2019_T03 | 2019-12-26 11:16 [view ] | -18.9007 | 120.0007 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-26 13:24 [view ] | -19.0833 | 119.6467 | Metstation | calibration | in2019_t03 | STBD PIR and PSR Calibration wrong calibration was accidently removed from 2019-12-26 13:24:34 to 2019-12-27 06:40 UTC | |
IN2019_T03 | 2019-12-26 15:49 [view ] | -19.2877 | 119.2495 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst015.asvp | |
IN2019_T03 | 2019-12-26 15:51 [view ] | -19.2910 | 119.2432 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst016_mixed.asvp | |
IN2019_T03 | 2019-12-26 15:53 [view ] | -19.2930 | 119.2393 | EM710 [view] | SVP | GSM_in2019_t03 | SVP applied in2019_t03_sst015.asvp | |
IN2019_T03 | 2019-12-26 16:38 [view ] | -19.3577 | 119.1137 | WinchServer | restarted | in2019_t03 | restarted research winch python script after crash | |
IN2019_T03 | 2019-12-26 17:15 [view ] | -19.4123 | 119.0073 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-26 17:15 [view ] | -19.4123 | 119.0073 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-26 20:26 [view ] | -19.7762 | 118.5040 | SBP [view] | Line | GSM_in2019_t03 | Power changed from -12 to -10dB & New line started (0010) | |
IN2019_T03 | 2019-12-26 21:00 [view ] | -19.8420 | 118.4135 | Metstation | calibration | in2019_t03 | PAR stdb and port cal wrong 26/12/19 21:00 to 27/12/19 06:50 PAR stbd and port were accidentally removed | |
IN2019_T03 | 2019-12-26 21:15 [view ] | -19.8665 | 118.3757 | Other [view] | GSM_in2019_t03 | Commence retrieval of CPR in preparation for arrival at Port Hedland station | ||
IN2019_T03 | 2019-12-26 21:24 [view ] | -19.8702 | 118.3632 | Other [view] | Other | GSM_in2019_t03 | CPR Recovered - navigating to station off Port Hedland | |
IN2019_T03 | 2019-12-26 21:24 [view ] | -19.8702 | 118.3632 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP - navigating to station off Port Hedland | |
IN2019_T03 | 2019-12-26 21:28 [view ] | -19.8670 | 118.3710 | CPR [view] | Retrieved | in2019_t03 | Retrieved cassette 2 | |
IN2019_T03 | 2019-12-26 21:32 [view ] | -19.8652 | 118.3815 | SBP [view] | Start | GSM_in2019_t03 | Resumed logging SBP for short transit to station | |
IN2019_T03 | 2019-12-26 21:36 [view ] | -19.8628 | 118.3850 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP - now on Station off Port Hedland | |
IN2019_T03 | 2019-12-26 21:36 [view ] | -19.8628 | 118.3850 | Other [view] | Other | GSM_in2019_t03 | On Station off Port Hedland | |
IN2019_T03 | 2019-12-26 21:43 [view ] | -19.8630 | 118.3847 | Rapid Cast [view] | SVP | GSM_in2019_t03 | RapidSV cast completed on station off Port Hedland | |
IN2019_T03 | 2019-12-26 21:52 [view ] | -19.8632 | 118.3845 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_rsvp_002.asvp applied | |
IN2019_T03 | 2019-12-26 22:05 [view ] | -19.8630 | 118.3847 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging of EM710 while on station (off Port Hedland) | |
IN2019_T03 | 2019-12-26 23:03 [view ] | -19.8620 | 118.3852 | TSG [view] | Maintenance | in2019_t03 | TSG filter cleaned | |
IN2019_T03 | 2019-12-26 23:03 [view ] | -19.8622 | 118.3848 | Fluorometer [view] | Maintenance | in2019_t03 | Fluorometer cleaned | |
IN2019_T03 | 2019-12-26 23:04 [view ] | -19.8623 | 118.3847 | pCO2 [view] | Maintenance | in2019_t03 | pCO2 filter cleaned | |
IN2019_T03 | 2019-12-26 23:04 [view ] | -19.8628 | 118.3840 | EM710 [view] | Start | GSM_in2019_t03 | Resumed logging EM710 - departing Port Hedland station | |
IN2019_T03 | 2019-12-26 23:04 [view ] | -19.8628 | 118.3840 | SBP [view] | Start | GSM_in2019_t03 | Resumed logging SBP120 - departing Port Hedland station | |
IN2019_T03 | 2019-12-26 23:28 [view ] | -19.8887 | 118.3188 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-27 04:27 [view ] | -20.0757 | 117.4122 | pCO2 [view] | Change | in2019_t03 | Changed operating software to V2-6 Stopped V2-5 software. Started running V2-6 (V12-6) software as per Craig Neill& 39;s instructions. | |
IN2019_T03 | 2019-12-27 05:14 [view ] | -20.0923 | 117.2627 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_017.asvp applied | |
IN2019_T03 | 2019-12-27 09:03 [view ] | -20.3003 | 116.5743 | Other [view] | Start | GSM_in2019_t03 | Ship stopped- on Radar station Dampier | |
IN2019_T03 | 2019-12-27 09:32 [view ] | -20.3002 | 116.5745 | EM710 [view] | Stop | GSM_in2019_t03 | Stop logging on station | |
IN2019_T03 | 2019-12-27 10:05 [view ] | -20.2990 | 116.5755 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-27 10:07 [view ] | -20.2990 | 116.5755 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-27 10:09 [view ] | -20.2990 | 116.5755 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-27 10:23 [view ] | -20.2985 | 116.5758 | EM710 [view] | Start | GSM_in2019_t03 | Start logging- drifting on station | |
IN2019_T03 | 2019-12-27 11:17 [view ] | -20.2972 | 116.5765 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-27 11:27 [view ] | -20.2972 | 116.5765 | EM710 [view] | Stop | GSM_in2019_t03 | Stop logging on station | |
IN2019_T03 | 2019-12-27 12:30 [view ] | -20.2943 | 116.5765 | Other [view] | Stop | GSM_in2019_t03 | Stop radar observations- moving off station | |
IN2019_T03 | 2019-12-27 14:51 [view ] | -20.4973 | 116.2203 | EK60 [view] | Other | GSM_in2019_t03 | 70kHz to passive to minimize interference with EM710 | |
IN2019_T03 | 2019-12-27 14:57 [view ] | -20.5097 | 116.2072 | EK60 [view] | Start | GSM_in2019_t03 | 70kHz back to active | |
IN2019_T03 | 2019-12-27 14:57 [view ] | -20.5102 | 116.2065 | EM710 [view] | Other | GSM_in2019_t03 | FIlters changed to Range Gate: small, Penetration: weak | |
IN2019_T03 | 2019-12-27 15:14 [view ] | -20.5450 | 116.1688 | SBP [view] | warning | GSM_in2019_t03 | Error and warning on Card 8 Ch 3&4, messy data | |
IN2019_T03 | 2019-12-27 15:14 [view ] | -20.5468 | 116.1668 | SBP [view] | Stop | GSM_in2019_t03 | Stop logging- restarting and troubleshooting | |
IN2019_T03 | 2019-12-27 15:40 [view ] | -20.6007 | 116.1078 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst018.asvp | |
IN2019_T03 | 2019-12-27 17:39 [view ] | -20.8420 | 115.8132 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst019.asvp | |
IN2019_T03 | 2019-12-27 18:13 [view ] | -20.9047 | 115.7268 | SBP [view] | Start | GSM_in2019_t03 | Restarted SBP but error persists on Card8. Resumed logging as data appears useable. Continuing to problem solve. Note: Very shallow water (18m). Power set to -25dB | |
IN2019_T03 | 2019-12-27 18:47 [view ] | -20.9705 | 115.6400 | Both | Drop | in2019_t03_VSAT | Interferance Both vsats frequently dropping out. Seeing massive amounts of interfeance on spectrum analiser | |
IN2019_T03 | 2019-12-27 19:06 [view ] | -21.0093 | 115.5955 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_020.asvp applied Very Shallow Water (17m) inshore of Barrow Island | |
IN2019_T03 | 2019-12-27 20:07 [view ] | -21.1632 | 115.5508 | EK60 [view] | Other | GSM_in2019_t03 | 70 kHz to passive - very shallow water & interferring with EM710 | |
IN2019_T03 | 2019-12-27 20:10 [view ] | -21.1672 | 115.5438 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_021.asvp applied | |
IN2019_T03 | 2019-12-27 22:02 [view ] | -21.1882 | 115.2082 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP - rebooting system in attempt to remove Card 8 errors. Water Depth 20m | |
IN2019_T03 | 2019-12-27 22:37 [view ] | -21.1437 | 115.1153 | SBP [view] | Start | GSM_in2019_t03 | Started logoging EM120 Disregard RAW Line_014_000 & 001 due to logging issue. SEGY version of these files seems OK. After rebooting the system (and Pre amp) Card 8 error remains - data is accepatble so continuing to log. | |
IN2019_T03 | 2019-12-27 22:47 [view ] | -21.1605 | 115.0895 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_022.asvp applied | |
IN2019_T03 | 2019-12-27 22:49 [view ] | -21.1620 | 115.0870 | EK60 [view] | Other | GSM_in2019_t03 | 70kHz back to active | |
IN2019_T03 | 2019-12-27 23:01 [view ] | -21.1800 | 115.0592 | CPR [view] | Deployed | in2019_t03 | deployed cassette 3 | |
IN2019_T03 | 2019-12-27 23:14 [view ] | -21.2028 | 115.0240 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_023.asvp applied | |
IN2019_T03 | 2019-12-28 01:00 [view ] | -21.3883 | 114.7373 | Other [view] | Other | GSM_in2019_t03 | CPR back on deck and SIT preparing for CTD | |
IN2019_T03 | 2019-12-28 01:06 [view ] | -21.3893 | 114.7352 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP while conducting CTD Ops | |
IN2019_T03 | 2019-12-28 01:08 [view ] | -21.3892 | 114.7350 | CPR [view] | Retrieved | in2019_t03 | Retrieved cassette 3 retreived while on station for ctd and EZ net | |
IN2019_T03 | 2019-12-28 01:30 [view ] | -21.3890 | 114.7362 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging EM710 while conducting CTD | |
IN2019_T03 | 2019-12-28 01:34 [view ] | -21.3893 | 114.7365 | EM710 [view] | Start | GSM_in2019_t03 | Started logging EM710 | |
IN2019_T03 | 2019-12-28 01:44 [view ] | -21.3918 | 114.7317 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_ctd_002.asvp applied SVP dervived from CTD cast 2 | |
IN2019_T03 | 2019-12-28 02:18 [view ] | -21.3978 | 114.7237 | CTD [view] | Elise Tuuri S2 | Deployed | in2019_t03 | CTD Deployed to collect bacterial and nanoplastic samples |
IN2019_T03 | 2019-12-28 02:20 [view ] | -21.4008 | 114.7188 | CTD [view] | Elise Tuuri S2 | Retrieved | in2019_t03 | CTD retrieved to collect bacteria and nanoplastic samples |
IN2019_T03 | 2019-12-28 02:23 [view ] | -21.4047 | 114.7108 | Other [view] | Other | GSM_in2019_t03 | Issue with EZ Net - Continuing along the route | |
IN2019_T03 | 2019-12-28 02:28 [view ] | -21.4117 | 114.6942 | SBP [view] | Start | GSM_in2019_t03 | Started logging SBP - Error on Card 8 remains Kongsberg suggested trying several things to isolate the problem. Cables were swapped to see if the problem moved to another card but this did not happen. Reseated Card 8 as well but issue remains. Will continue to acquire data until next station (data is marginal but acceptable) and will then work on replacing the card and retesting. Changed RX to Half Array to try and minimize noise. | |
IN2019_T03 | 2019-12-28 03:26 [view ] | -21.4890 | 114.5237 | EK60 [view] | Other | GSM_in2019_t03 | 70 kHz to passive - interferring badly with EM710 (wd = 100m) Can not synchronise with K-Sync to remove interference so had to deactive 70KHz on the EK60. | |
IN2019_T03 | 2019-12-28 03:29 [view ] | -21.4890 | 114.5233 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP while conducting a CTD | |
IN2019_T03 | 2019-12-28 03:54 [view ] | -21.4892 | 114.5237 | CTD [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-28 03:55 [view ] | -21.4895 | 114.5237 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging EM710 while conducting CTD Ops | |
IN2019_T03 | 2019-12-28 04:17 [view ] | -21.4913 | 114.5242 | CTD [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-28 04:29 [view ] | -21.4930 | 114.5220 | EZNet [view] | Start | in2019_t03 | ||
IN2019_T03 | 2019-12-28 04:30 [view ] | -21.4932 | 114.5210 | EM710 [view] | Start | GSM_in2019_t03 | Started logging EM710 | |
IN2019_T03 | 2019-12-28 04:30 [view ] | -21.4932 | 114.5210 | SBP [view] | Start | GSM_in2019_t03 | Started logging SBP | |
IN2019_T03 | 2019-12-28 04:56 [view ] | -21.4975 | 114.5042 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_ctd_003.asvp applied | |
IN2019_T03 | 2019-12-28 05:49 [view ] | -21.5137 | 114.4725 | EZNet [view] | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-28 05:52 [view ] | -21.5177 | 114.4643 | CPR [view] | Deployed | in2019_t03 | re-deployed cassette three | |
IN2019_T03 | 2019-12-28 07:02 [view ] | -21.6103 | 114.2572 | Fluorometer [view] | in2019_t03 | Filter Cleaned | ||
IN2019_T03 | 2019-12-28 07:02 [view ] | -21.6107 | 114.2563 | pCO2 [view] | Filter Clean | in2019_t03 | ||
IN2019_T03 | 2019-12-28 07:03 [view ] | -21.6112 | 114.2552 | TSG [view] | Filter Clean | in2019_t03 | ||
IN2019_T03 | 2019-12-28 08:00 [view ] | -21.6528 | 114.0770 | SBP [view] | Other | GSM_in2019_t03 | Changed window size to 200 on slope | |
IN2019_T03 | 2019-12-28 08:14 [view ] | -21.6582 | 114.0322 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst024.asvp | |
IN2019_T03 | 2019-12-28 08:52 [view ] | -21.7142 | 113.9232 | EK60 [view] | Other | GSM_in2019_t03 | Data output logging range to 1500m | |
IN2019_T03 | 2019-12-28 09:11 [view ] | -21.7488 | 113.8698 | SBP [view] | Other | GSM_in2019_t03 | Window to 500 | |
IN2019_T03 | 2019-12-28 09:15 [view ] | -21.7557 | 113.8592 | SBP [view] | Power | GSM_in2019_t03 | Power to -18dB. Changed to linear chrip up, matched filter | |
IN2019_T03 | 2019-12-28 09:16 [view ] | -21.7573 | 113.8568 | EM122 [view] | Start | GSM_in2019_t03 | Start logging | |
IN2019_T03 | 2019-12-28 09:28 [view ] | -21.7738 | 113.8317 | CPR [view] | Recover | in2019_t03 | Retrieved cassette 3 | |
IN2019_T03 | 2019-12-28 09:29 [view ] | -21.7755 | 113.8290 | EM710 [view] | Stop | GSM_in2019_t03 | Stop logging on station | |
IN2019_T03 | 2019-12-28 09:32 [view ] | -21.7772 | 113.8270 | Other [view] | Start | GSM_in2019_t03 | On radar station | |
IN2019_T03 | 2019-12-28 09:58 [view ] | -21.7788 | 113.8272 | SBP [view] | Stop | GSM_in2019_t03 | Stop logging on station- restarting | |
IN2019_T03 | 2019-12-28 11:16 [view ] | -21.7778 | 113.8257 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-28 12:33 [view ] | -21.7777 | 113.8253 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-28 12:35 [view ] | -21.7777 | 113.8253 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-28 12:37 [view ] | -21.7777 | 113.8252 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-28 12:58 [view ] | -21.7763 | 113.8228 | Other [view] | Stop | GSM_in2019_t03 | Stop radar observations- moving off station | |
IN2019_T03 | 2019-12-28 13:01 [view ] | -21.7770 | 113.8197 | CPR [view] | Deployed | in2019_t03 | Deployed cassette 4 | |
IN2019_T03 | 2019-12-28 13:02 [view ] | -21.7775 | 113.8187 | EM122 [view] | Start | GSM_in2019_t03 | Start logging on transit | |
IN2019_T03 | 2019-12-28 13:02 [view ] | -21.7778 | 113.8183 | SBP [view] | Start | GSM_in2019_t03 | Start logging- linear chirp up, 30ms pulse power -15dB | |
IN2019_T03 | 2019-12-28 13:11 [view ] | -21.7977 | 113.8055 | Oxygen Analyser [view] | Maintenance | in2019_t03_Atmospherics | trap dryer changed | |
IN2019_T03 | 2019-12-28 18:41 [view ] | -22.6862 | 113.4682 | EM122 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_025.asvp applied | |
IN2019_T03 | 2019-12-28 19:21 [view ] | -22.8003 | 113.4460 | EK60 [view] | File | GSM_in2019_t03 | Changed Useer settings and logging to 250m Water Depth 230m | |
IN2019_T03 | 2019-12-28 19:39 [view ] | -22.8508 | 113.4362 | EM710 [view] | Start | GSM_in2019_t03 | Started logging EM710 (wd = 210m) | |
IN2019_T03 | 2019-12-28 20:15 [view ] | -22.9533 | 113.4162 | EM122 [view] | Stop | GSM_in2019_t03 | Stopped logging EM122 - wd = 180m | |
IN2019_T03 | 2019-12-28 20:49 [view ] | -23.0523 | 113.3970 | SBP [view] | Power | GSM_in2019_t03 | Power changed from -15 to -18dB (shallower water) | |
IN2019_T03 | 2019-12-28 21:28 [view ] | -23.1680 | 113.3745 | Other [view] | GSM_in2019_t03 | Window size to 250ms | ||
IN2019_T03 | 2019-12-28 21:37 [view ] | -23.1942 | 113.3692 | EM710 [view] | Other | GSM_in2019_t03 | ADCP (75kHz) truned off due to interferebce with EM710 Found that 75kHZ ADCP was badly interfering with the EM710 in ~130m water depth. DAP turned this freq. off and kept 150kHz running. Data improved immensely! | |
IN2019_T03 | 2019-12-29 00:10 [view ] | -23.6442 | 113.2813 | SBP [view] | Other | GSM_in2019_t03 | Changed from Linear Chirp/Matched back to Ricker/Bandpass (in 100m water depth) Also changed window size to 200ms and remained on Half Array for RX. | |
IN2019_T03 | 2019-12-29 00:28 [view ] | -23.6983 | 113.2708 | Fluorometer [view] | Maintenance | in2019_t03 | Flow rate reset to 1.5 | |
IN2019_T03 | 2019-12-29 00:32 [view ] | -23.7093 | 113.2687 | SBP [view] | Power | GSM_in2019_t03 | Stopped logging and turned off power to SBP - Changed over HD8 Cards 8 & 7 Swapped cards 8 & 7 to see if the issue moves to the card 7 position. Not logging data. | |
IN2019_T03 | 2019-12-29 01:02 [view ] | -23.7947 | 113.2520 | SBP [view] | Start | GSM_in2019_t03 | Restarted logging SBP 120 with HD8 Cards 8 & 7 swapped Data is noisy but no errors showing on the cards (tested from -30 to 0dB) | |
IN2019_T03 | 2019-12-29 01:12 [view ] | -23.8220 | 113.2465 | SBP [view] | Other | GSM_in2019_t03 | Stopped logging and turned off power to SBP - Changed over HD8 Cards 8 & 7 back to original position | |
IN2019_T03 | 2019-12-29 01:41 [view ] | -23.9080 | 113.2297 | SBP [view] | Start | GSM_in2019_t03 | Resumed logging SBP (HD8 Cards back to original positions) | |
IN2019_T03 | 2019-12-29 03:19 [view ] | -24.1943 | 113.2253 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_026.asvp applied | |
IN2019_T03 | 2019-12-29 03:42 [view ] | -24.2633 | 113.2422 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_027.asvp applied | |
IN2019_T03 | 2019-12-29 04:46 [view ] | -24.4532 | 113.2888 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_028.asvp applied | |
IN2019_T03 | 2019-12-29 06:05 [view ] | -24.6522 | 113.3363 | Other [view] | Start | GSM_in2019_t03 | Ship stationary- Start Radar observations | |
IN2019_T03 | 2019-12-29 06:06 [view ] | -24.6520 | 113.3362 | CPR [view] | Retrieved | in2019_t03 | Retrieved cassette 4 | |
IN2019_T03 | 2019-12-29 06:43 [view ] | -24.6512 | 113.3322 | POSMV [view] | Other | GSM_in2019_t03 | Swapped USB logging sticks | |
IN2019_T03 | 2019-12-29 06:54 [view ] | -24.6508 | 113.3310 | EM710 [view] | Stop | GSM_in2019_t03 | Stop logging on station | |
IN2019_T03 | 2019-12-29 07:10 [view ] | -24.6507 | 113.3298 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2019-12-29 07:31 [view ] | -24.6503 | 113.3265 | EM710 [view] | Start | GSM_in2019_t03 | Start logging on transit | |
IN2019_T03 | 2019-12-29 07:35 [view ] | -24.6510 | 113.3195 | CPR [view] | Deployed | in2019_t03 | Redeployed cassette 4 | |
IN2019_T03 | 2019-12-29 08:33 [view ] | -24.6672 | 113.1295 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-29 08:34 [view ] | -24.6673 | 113.1243 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-29 08:36 [view ] | -24.6677 | 113.1188 | Underway | steve vg Hydrochem Lab : | Sample | TSG_Samples_in2019_t03 | |
IN2019_T03 | 2019-12-29 08:53 [view ] | -24.6713 | 113.0598 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst029.asvp | |
IN2019_T03 | 2019-12-29 10:09 [view ] | -24.8330 | 112.9442 | EM710 [view] | GSM_in2019_t03 | Heave artifact? | ||
IN2019_T03 | 2019-12-29 10:44 [view ] | -24.9227 | 112.9115 | SBP [view] | Other | GSM_in2019_t03 | Brief change to linear chirp up, then back to ricker pulse | |
IN2019_T03 | 2019-12-29 10:53 [view ] | -24.9447 | 112.9035 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst030.asvp | |
IN2019_T03 | 2019-12-29 11:47 [view ] | -25.0840 | 112.8525 | EM710 [view] | SVP | GSM_in2019_t03 | SVP applied in2019_t03_sst029.asvp | |
IN2019_T03 | 2019-12-29 11:50 [view ] | -25.0927 | 112.8493 | SBP [view] | Pulse form | GSM_in2019_t03 | Changed to linear chirp up, power -18dB, pulse 12ms | |
IN2019_T03 | 2019-12-29 13:04 [view ] | -25.2732 | 112.7832 | EM710 [view] | SVP | GSM_in2019_t03 | SVP applied in2019_t03_sst030.asvp | |
IN2019_T03 | 2019-12-29 13:36 [view ] | -25.3535 | 112.7538 | SBP [view] | Power | GSM_in2019_t03 | Power to -15dB | |
IN2019_T03 | 2019-12-29 13:43 [view ] | -25.3702 | 112.7477 | EM710 [view] | SVP | GSM_in2019_t03 | SVP applied in2019_t03_sst029.asvp | |
IN2019_T03 | 2019-12-29 14:23 [view ] | -25.4702 | 112.7162 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_sst031.asvp | |
IN2019_T03 | 2019-12-29 15:02 [view ] | -25.5622 | 112.7552 | EM710 [view] | Pulse form | GSM_in2019_t03 | Changed from linear chirp to ricker | |
IN2019_T03 | 2019-12-29 15:35 [view ] | -25.6398 | 112.7882 | EM122 [view] | Start | GSM_in2019_t03 | Start logging EM122 | |
IN2019_T03 | 2019-12-29 16:56 [view ] | -25.8308 | 112.8695 | EM122 [view] | Stop | GSM_in2019_t03 | Stop logging/pinging | |
IN2019_T03 | 2019-12-29 22:28 [view ] | -26.6415 | 113.2160 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_032.asvp applied | |
IN2019_T03 | 2019-12-30 02:33 [view ] | -27.2775 | 113.4895 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_033.asvp applied | |
IN2019_T03 | 2019-12-30 03:50 [view ] | -27.4642 | 113.5708 | Other [view] | GSM_in2019_t03 | Vessel stopping in preparation for CTD cast and possible EZ Net deployment thereafter. | ||
IN2019_T03 | 2019-12-30 03:51 [view ] | -27.4637 | 113.5707 | CTD [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-30 03:54 [view ] | -27.4620 | 113.5703 | CPR [view] | Retrieved | in2019_t03 | Retrieved cassette 4 | |
IN2019_T03 | 2019-12-30 03:58 [view ] | -27.4602 | 113.5698 | Other [view] | GSM_in2019_t03 | Checked on the RapidSV and placed cover on it. No water in the box. | ||
IN2019_T03 | 2019-12-30 03:59 [view ] | -27.4600 | 113.5698 | Other [view] | GSM_in2019_t03 | CTD depployed | ||
IN2019_T03 | 2019-12-30 04:07 [view ] | -27.4593 | 113.5705 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging SBP while conducting CTD Ops | |
IN2019_T03 | 2019-12-30 04:14 [view ] | -27.4592 | 113.5707 | CTD [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-30 04:14 [view ] | -27.4592 | 113.5708 | Other [view] | GSM_in2019_t03 | CTD back on deck | ||
IN2019_T03 | 2019-12-30 04:30 [view ] | -27.4610 | 113.5712 | EZNet [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-30 04:30 [view ] | -27.4610 | 113.5712 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_ctd_004.asvp applied | |
IN2019_T03 | 2019-12-30 04:33 [view ] | -27.4615 | 113.5713 | Other [view] | GSM_in2019_t03 | EZ Net deployed | ||
IN2019_T03 | 2019-12-30 04:58 [view ] | -27.4663 | 113.5725 | SBP [view] | Start | GSM_in2019_t03 | Started logging SBP - EZ Net deployment aborted due to sea conditions - moving on | |
IN2019_T03 | 2019-12-30 05:00 [view ] | -27.4670 | 113.5727 | EZNet [view] | Retrieved | in2019_t03 | EZ net retrieved early as the winch tension values were consistenltly too high. | |
IN2019_T03 | 2019-12-30 06:00 [view ] | -27.6152 | 113.6355 | SBP [view] | warning | GSM_in2019_t03 | HD8-8 Channels 3/4 have again dropped out (Red Error Warning) | |
IN2019_T03 | 2019-12-30 07:22 [view ] | -27.8355 | 113.7310 | Oxygen Analyser [view] | Change | in2019_t03_Atmospherics | WT1 tank replaced with new cylinder WT1 tank replaced with new cylinder, WT2 empty this was removed too. | |
IN2019_T03 | 2019-12-30 11:05 [view ] | -28.4128 | 114.0200 | Other [view] | Start | GSM_in2019_t03 | Bridge echosounder on | |
IN2019_T03 | 2019-12-30 11:11 [view ] | -28.4248 | 114.0338 | SBP [view] | Power | GSM_in2019_t03 | Power to -18dB | |
IN2019_T03 | 2019-12-30 14:58 [view ] | -28.8522 | 114.5288 | Other [view] | Start | GSM_in2019_t03 | Ship stationary- Start Radar observations | |
IN2019_T03 | 2019-12-30 15:52 [view ] | -28.8595 | 114.5338 | EM710 [view] | Stop | GSM_in2019_t03 | Stop pinging- error on RX BSP status | |
IN2019_T03 | 2019-12-30 15:54 [view ] | -28.8595 | 114.5338 | SBP [view] | Stop | GSM_in2019_t03 | Stop logging while troubleshooting EM710 | |
IN2019_T03 | 2019-12-30 15:55 [view ] | -28.8595 | 114.5338 | EM710 [view] | Other | GSM_in2019_t03 | Restarting SIS | |
IN2019_T03 | 2019-12-30 15:58 [view ] | -28.8595 | 114.5337 | Other [view] | GSM_in2019_t03 | Bridge sounder off | ||
IN2019_T03 | 2019-12-30 16:04 [view ] | -28.8595 | 114.5338 | EM710 [view] | GSM_in2019_t03 | Restarted transducer | ||
IN2019_T03 | 2019-12-30 16:06 [view ] | -28.8595 | 114.5337 | EM710 [view] | Start | GSM_in2019_t03 | Start pinging and logging, no more error | |
IN2019_T03 | 2019-12-30 16:07 [view ] | -28.8595 | 114.5337 | SBP [view] | Start | GSM_in2019_t03 | Start pinging/logging | |
IN2019_T03 | 2019-12-30 16:13 [view ] | -28.8602 | 114.5337 | Other [view] | Stop | GSM_in2019_t03 | Stop radar observations- moving off station | |
IN2019_T03 | 2019-12-30 19:19 [view ] | -29.3175 | 114.6033 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP in2019_t03_sst_034.asvp applied | |
IN2019_T03 | 2019-12-30 20:41 [view ] | -29.5262 | 114.6333 | EM710 [view] | Other | GSM_in2019_t03 | Port & Stbd anlgs changed to 72° | |
IN2019_T03 | 2019-12-30 21:31 [view ] | -29.6530 | 114.6518 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging briefly to change Installation parameters Changed Positioning to Seapath (i.e. from COM1 --> COM4 and COM2 --> COM3) to see if motion arefact is removed from data. Restarted logging on file 0218 with the Seapath as the Nav/Motion reference. No difference observed in motion artefacts. | |
IN2019_T03 | 2019-12-30 21:36 [view ] | -29.6665 | 114.6537 | EM710 [view] | Other | GSM_in2019_t03 | Changed SIS sensor setup back to COM1 & 2 (Posmv as Nav/IMU Source) Motion aretafcts still present in bathy data. | |
IN2019_T03 | 2019-12-30 23:34 [view ] | -29.9695 | 114.6977 | EM710 [view] | Other | GSM_in2019_t03 | Heave bandwidth change to 10 seconds in posmv | |
IN2019_T03 | 2019-12-30 23:52 [view ] | -30.0195 | 114.7048 | Picarro Spectrometer [view] | Maintenance | in2019_t03_Atmospherics | System restarted Instrument was reading at irregular time periods so system reset was required. | |
IN2019_T03 | 2019-12-31 00:07 [view ] | -30.0580 | 114.7105 | TSG [view] | Filter Clean | in2019_t03 | TSG filter cleaned | |
IN2019_T03 | 2019-12-31 00:07 [view ] | -30.0587 | 114.7105 | Fluorometer [view] | Cleaned | in2019_t03 | Fluorometer cleaned | |
IN2019_T03 | 2019-12-31 00:07 [view ] | -30.0593 | 114.7107 | pCO2 [view] | Filter Clean | in2019_t03 | pCO2 filter cleaned | |
IN2019_T03 | 2019-12-31 04:02 [view ] | -30.6818 | 114.8033 | SBP [view] | Power | GSM_in2019_t03 | Power to from -17 to -15dB | |
IN2019_T03 | 2019-12-31 04:44 [view ] | -30.7410 | 114.7477 | CTD [view] | Deployed | in2019_t03 | ||
IN2019_T03 | 2019-12-31 04:44 [view ] | -30.7409 | 114.7485 | CTD [view] | Retrieved | in2019_t03 | ||
IN2019_T03 | 2019-12-31 04:46 [view ] | -30.7410 | 114.7477 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging EM710 & SBP while conducting CTD Ops | |
IN2019_T03 | 2019-12-31 05:36 [view ] | -30.7408 | 114.7487 | Other [view] | GSM_in2019_t03 | No EZ Net Trawl - conditions not favourable for deployment | ||
IN2019_T03 | 2019-12-31 05:43 [view ] | -30.7408 | 114.7490 | EM710 [view] | Start | GSM_in2019_t03 | Started logging Em710 - leaving CTD station | |
IN2019_T03 | 2019-12-31 05:43 [view ] | -30.7408 | 114.7490 | SBP [view] | Start | GSM_in2019_t03 | Started logging SBP - leaving CTD station | |
IN2019_T03 | 2019-12-31 06:09 [view ] | -30.7927 | 114.7722 | EM710 [view] | SVP | GSM_in2019_t03 | New SVP applied in2019_t03_ctd_005.asvp | |
IN2019_T03 | 2019-12-31 14:14 [view ] | -31.5680 | 115.1372 | CPC 3772 [view] | Maintenance | in2019_t03_Atmospherics | butanol refill | |
IN2019_T03 | 2019-12-31 14:14 [view ] | -31.5695 | 115.1378 | CCNC [view] | Maintenance | in2019_t03_Atmospherics | Filled and emptied Milli-q | |
IN2019_T03 | 2019-12-31 17:27 [view ] | -31.8530 | 115.3298 | EM710 [view] | Start | GSM_in2019_t03 | Start latency line 1 - 8 knots up slope | |
IN2019_T03 | 2019-12-31 21:14 [view ] | -31.9843 | 115.6587 | Other [view] | GSM_in2019_t03 | Slowing down - arrival at Pilot boarding area | ||
IN2019_T03 | 2019-12-31 21:18 [view ] | -31.9867 | 115.6607 | EK60 [view] | Stop | GSM_in2019_t03 | Stopped logging & pinging EK60 and turned all channles to PASSIVE in preparation for aising of drop keels | |
IN2019_T03 | 2019-12-31 21:20 [view ] | -31.9885 | 115.6623 | SBP [view] | Stop | GSM_in2019_t03 | Stopped logging & pinging SBP (wd=13m) arriving at Pilot boarding station | |
IN2019_T03 | 2019-12-31 21:26 [view ] | -31.9918 | 115.6653 | ADCP [view] | Stop | in2019_t03 | ADCPs STopped Cruise ended, in very shallow water for rest of voyage and drop keels will be raised soon | |
IN2019_T03 | 2019-12-31 21:29 [view ] | -31.9942 | 115.6675 | Instrumentation Clean Seawater Pump [view] | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-31 21:30 [view ] | -31.9945 | 115.6677 | TSG [view] | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-31 21:30 [view ] | -31.9945 | 115.6678 | Fluorometer [view] | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-31 21:30 [view ] | -31.9947 | 115.6678 | pCO2 [view] | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-31 21:30 [view ] | -31.9948 | 115.6680 | Oxygen Optode | Stop | in2019_t03 | ||
IN2019_T03 | 2019-12-31 21:57 [view ] | -32.0172 | 115.6842 | Other [view] | GSM_in2019_t03 | Pilot on board | ||
IN2019_T03 | 2019-12-31 23:19 [view ] | -32.2003 | 115.6988 | EM710 [view] | Stop | GSM_in2019_t03 | Stopped logging & pinging EM710 (wd=21m). Stopped for bunkering Fuel barge alongsode. All mapping sonar operations terminated. | |
IN2019_T03 | 2020-01-01 01:26 [view ] | -32.1998 | 115.6997 | Deployed | WeatherBalloon_in2019_t03 | |||
IN2019_T03 | 2020-01-02 00:39 [view ] | -32.1608 | 115.7583 | POSMV [view] | Stop | GSM_in2019_t03 | Stopped logging POSMV Ethernet & USB - Entrance to Henderson | |
IN2019_T03 | 2020-01-02 00:41 [view ] | -32.1580 | 115.7573 | Other [view] | Other | GSM_in2019_t03 | Vessel turned around in Henderson and heading back out of port | |
IN2019_T03 | 2020-01-02 05:00 [view ] | -32.1537 | 115.7650 | Techsas1 [view] | Stop | in2019_t03 | end of voyage | |
IN2019_T03 | 2020-01-02 05:04 [view ] | -32.1537 | 115.7650 | Other [view] | GSM_in2019_t03 | Alongside in Henderson - end of voyage | ||
IN2019_T03 | 2020-01-02 05:05 [view ] | -32.1537 | 115.7650 | Other [view] | GSM_in2019_t03 | POSMV & EM710 PC rebooted |