Data Trawler - Search Events

Please login if you have access to particular applications.
Username:
Password:

Search for events by voyage, equipment, action or within comments.

Event count for each voyage, equipment or action is shown in ().

Voyage(s)
Elog Set(s)
Equipment(s)
Action
Search for - within subject, event identifier, comments etc.(case insensitive)
Highlight matches

Caveat: this event log was authored on the voyage using either a standalone logging system called ELOG or more recently an inhouse event logging tool called Everlog. For this reason, some positions are unknown and may be resolved using the logged time and the underway dataset for the voyage.

Events ordered by start time:- Click on column header to sort. Use link on 'When' to see full details. Use the CSV button at the bottom to export data.

Survey When (UTC) LatitudeLongitude InstrumentIdentifierActionLogSubject / Comments
IN2017_T01 2017-09-24 10:02 [view ] Techsas1 [view] Start in2017_t01 Techsas 1 and 2 started
IN2017_T01 2017-09-24 11:13 [view ] -33.8360 151.3028 ADCP [view] Start in2017_t01 OS75 started in bottom tracking mode, drop keel flush with hull
IN2017_T01 2017-09-24 12:06 [view ] -33.8388 151.3625 EM710 [view] Start GSM_in2017_t01 Start recording Start recording EM710
IN2017_T01 2017-09-24 14:42 [view ] -33.7193 151.4835 Drop keel [view] Change in2017_t01 drop keel changed to 2m
IN2017_T01 2017-09-24 14:43 [view ] -33.7185 151.4843 ADCP [view] restarted in2017_t01 os75 restarted logging due to change in drop keel position to 2m
IN2017_T01 2017-09-24 15:38 [view ] -33.6633 151.5353 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst001.asvp
IN2017_T01 2017-09-24 19:45 [view ] -33.3823 151.7773 pCO2 [view] Start in2017_t01 pCO2 started once water started
IN2017_T01 2017-09-24 19:51 [view ] -33.3757 151.7829 Fluorometer [view] Start in2017_t01 Fluortomter started once instrument clean water running
IN2017_T01 2017-09-24 20:27 [view ] -33.2900 151.8554 TSG [view] Start in2017_t01 TSG Start
IN2017_T01 2017-09-24 21:34 [view ] -33.1139 152.0043 SST [view] Fault in2017_t01 SST Stopped responing.
IN2017_T01 2017-09-24 22:49 [view ] -32.9199 152.1678 SST [view] restarted in2017_t01 SST restarted broadcasting after reset of comms chains
IN2017_T01 2017-09-25 01:05 [view ] -32.5876 152.4824 Other [view] restarted in2017_t01 Rsync restarted
IN2017_T01 2017-09-25 04:34 [view ] -31.9784 152.7760 ADCP [view] Change in2017_t01 OS75 turned off bottom tracking. drop keel still at 2m
IN2017_T01 2017-09-25 15:19 [view ] -30.0381 153.4139 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst002.asvp SST= 20.9 Sal= 35.6
IN2017_T01 2017-09-25 18:01 [view ] -29.5342 153.5535 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst003.asvp SST = 19.94 Sal = 35.6
IN2017_T01 2017-09-25 19:24 [view ] -29.2576 153.6424 TSG [view] restarted in2017_t01 Changed filter.
IN2017_T01 2017-09-25 20:33 [view ] -29.0413 153.6667 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst004.asvp SST = 18.77 SAL = 35.5
IN2017_T01 2017-09-25 20:58 [view ] -28.9670 153.6852 EM710 [view] Depth Mode GSM_in2017_t01 New SVP applied in2017_t01_sst005.asvp SST = 20.01 SAL = 35.6
IN2017_T01 2017-09-25 22:02 [view ] -28.7748 153.7173 CCTV Start in2017_t01 Moved Side Science Area Camera to plastic debris monitoring position
IN2017_T01 2017-09-26 01:09 [view ] -28.1759 153.7221 Trace Metal Pump [view] Stop in2017_t01
IN2017_T01 2017-09-26 01:16 [view ] -28.1524 153.7216 Metstation outage in2017_t01 Port humidity and radiation down earlier today
IN2017_T01 2017-09-26 03:20 [view ] -27.7495 153.6916 CCTV restarted in2017_t01 clients would not connect to server
IN2017_T01 2017-09-26 04:23 [view ] -27.5567 153.6750 XBT [view] Drop GSM_in2017_t01 XBT drop 1
IN2017_T01 2017-09-26 04:28 [view ] -27.5422 153.6731 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_xbt001_svpb.asvp
IN2017_T01 2017-09-26 05:17 [view ] -27.3950 153.6621 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst006.asvp SST= 22.1C
IN2017_T01 2017-09-26 07:13 [view ] -27.0324 153.6392 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst007.asvp SST= 23.0C
IN2017_T01 2017-09-26 16:09 [view ] -25.2340 153.5420 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst008.asvp sst = 21.07 sal = 35.6
IN2017_T01 2017-09-26 19:17 [view ] -24.7105 153.5823 EM122 [view] Start GSM_in2017_t01 Start logging EM122
IN2017_T01 2017-09-26 19:20 [view ] -24.7015 135.5837 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst009.asvp sst = 23.61 sal = 35.5 em710 0064 em122 0000
IN2017_T01 2017-09-26 20:36 [view ] -24.4657 153.6240 EM710 [view] Stop GSM_in2017_t01 Stop logging EM710 Stop logging EM710 WD > 2000m
IN2017_T01 2017-09-27 00:10 [view ] -23.8021 153.7370 Fluorometer [view] Stop & Start in2017_t01 Fluorometer stopped for cleaning
IN2017_T01 2017-09-27 01:44 [view ] -23.5110 153.7762 EM710 [view] Start GSM_in2017_t01 Restart logging EM710 Restart logging EM710 WD ~ 800m
IN2017_T01 2017-09-27 02:12 [view ] -23.4250 153.7861 Trace Metal Pump [view] Start in2017_t01
IN2017_T01 2017-09-27 03:41 [view ] -23.1568 153.8168 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst010.asvp
IN2017_T01 2017-09-27 03:41 [view ] -23.1550 153.8170 VSAT restarted in2017_t01 window washing
IN2017_T01 2017-09-27 03:42 [view ] -23.1521 153.8173 EM710 [view] GSM_in2017_t01 EM710 'locked' to 40Khz
IN2017_T01 2017-09-27 08:48 [view ] -22.2007 153.9258 EK60 [view] Other GSM_in2017_t01 EAL program started
IN2017_T01 2017-09-27 11:48 [view ] -21.6032 153.8900 EM122 [view] Start GSM_in2017_t01 Start logging EM122
IN2017_T01 2017-09-27 12:08 [view ] -21.5477 153.8696 EM710 [view] Crash GSM_in2017_t01 Restart SIS- gridding not working
IN2017_T01 2017-09-27 20:50 [view ] -19.9836 153.2950 CCN [view] restarted in2017_t01 No particle count - Status Reset
IN2017_T01 2017-09-27 21:01 [view ] -19.9528 153.2838 CPC [view] maintenance in2017_t01 Emptied catchpot of butanol.
IN2017_T01 2017-09-28 00:11 [view ] -19.3649 153.0694 EM710 [view] Stop GSM_in2017_t01 Stop logging EM710 Stop logging EM710 data noisy in deep water
IN2017_T01 2017-09-28 02:04 [view ] -19.0105 152.9404 Radon detector [view] maintenance in2017_t01 Increased tank pressure to 120 as per ANSTO instructions.
IN2017_T01 2017-09-28 04:01 [view ] -28.6450 152.8078 EM122 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst011.asvp
IN2017_T01 2017-09-28 09:24 [view ] -17.6458 152.4467 EM710 [view] Start GSM_in2017_t01 Restart logging EM710
IN2017_T01 2017-09-28 12:46 [view ] -17.0256 152.2090 EM122 [view] Stop GSM_in2017_t01 Stop logging EM122 in shallow water
IN2017_T01 2017-09-28 15:00 [view ] -16.7206 151.8665 Techsas2 [view] restarted in2017_t01 interface froze
IN2017_T01 2017-09-28 19:30 [view ] -16.0858 151.1620 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst012.asvp New SVP applied in2017_t01_sst012.asvp sst = 26.02 sal = 35.05
IN2017_T01 2017-09-28 20:39 [view ] -15.9367 150.9888 CCN [view] restarted in2017_t01 No particle count - Status Reset
IN2017_T01 2017-09-28 22:02 [view ] -15.7557 150.7866 Other [view] restarted in2017_t01 influx VM restarted. Added CPU
IN2017_T01 2017-09-28 22:03 [view ] -15.7534 150.7841 Underway Cassie Schwanger Hydrochem Lab : uwy001 Sample Hydrochem_in2017_t01
IN2017_T01 2017-09-29 01:16 [view ] -15.3267 150.3083 Other [view] Reboot in2017_t01 acronis-server rebooting
IN2017_T01 2017-09-29 03:36 [view ] -15.0232 149.9702 EM710 [view] Stop GSM_in2017_t01 Stop logging EM710
IN2017_T01 2017-09-29 03:36 [view ] -15.0232 149.9702 EM122 [view] Start GSM_in2017_t01 Start logging EM122
IN2017_T01 2017-09-29 05:12 [view ] -14.8231 149.7480 Wind Sensor Other in2017_t01 Birds Birds sitting on the RM Young wind vanes, wind speed will be erroneous
IN2017_T01 2017-09-29 17:10 [view ] -13.2191 147.9719 CCN [view] restarted in2017_t01 No particle count - Status Reset
IN2017_T01 2017-09-29 17:42 [view ] -13.1426 147.8874 TSG [view] maintenance in2017_t01 Filter cleaned
IN2017_T01 2017-09-29 17:46 [view ] -13.1356 147.8796 SMPS [view] Stop in2017_t01 SMPS stopped due to high RH
IN2017_T01 2017-09-29 17:47 [view ] -13.1332 147.8770 Nephelometer [view] Stop in2017_t01 Nephelometer stopped due to high RH
IN2017_T01 2017-09-29 17:47 [view ] -13.1309 147.8744 CPC [view] Stop in2017_t01 CPC stopped due to high RH
IN2017_T01 2017-09-29 20:59 [view ] -12.6812 147.3789 Metstation Other in2017_t01 Birds all left with the sun The large number of birds, ~70, that were still present at 3am have departed with the sun.
IN2017_T01 2017-09-29 21:56 [view ] -12.5521 147.2368 Underway Morgane Hydrochem Lab : uwy002 Sample Hydrochem_in2017_t01
IN2017_T01 2017-09-29 22:49 [view ] -12.4275 147.0997 Other [view] Reboot in2017_t01 DB1
IN2017_T01 2017-09-30 07:30 [view ] -11.2529 145.8105 Underway morgane perron Hydrochem Lab : uwy003 Sample Hydrochem_in2017_t01
IN2017_T01 2017-09-30 15:09 [view ] -10.2622 144.7274 EM710 [view] Start GSM_in2017_t01 Start logging EM710
IN2017_T01 2017-09-30 16:04 [view ] -10.1152 144.6446 Ozone [view] Shutdown in2017_t01 ozone water trap emptied, both monitors shutdown to empty trap to avoid water sucking through
IN2017_T01 2017-09-30 17:22 [view ] -9.9197 144.6632 EM710 [view] Other GSM_in2017_t01 Restart EM710 Restart EM710 as couldn& 39;t change runtime parameters
IN2017_T01 2017-09-30 18:08 [view ] -9.8456 144.7773 Other [view] GSM_in2017_t01 Line Increment Line Increment prior to going over & 39;55m sounding& 39; in Pandora passage Em710 - 0117 Em122 - 0077
IN2017_T01 2017-09-30 18:16 [view ] -9.8299 144.7648 Other [view] in2017_t01 Phone - removed DST
IN2017_T01 2017-09-30 20:02 [view ] -9.7077 144.6676 EM122 [view] Stop GSM_in2017_t01 Start logging EM122 Start logging EM122 Water depth 250m
IN2017_T01 2017-09-30 20:30 [view ] -9.6359 144.6104 MAAP [view] Stop in2017_t01 MAAP found stopped on error.
IN2017_T01 2017-09-30 21:55 [view ] -9.4175 144.4367 Aerosol Lab [view] Change in2017_t01 T&RH sensor moved from nafion outlet to Bowie experiment outlet.
IN2017_T01 2017-09-30 22:06 [view ] -9.3892 144.4143 Aerodyne [view] Stop in2017_t01 Aerodyne found stopped on error.
IN2017_T01 2017-09-30 22:31 [view ] -9.3278 144.3655 Aerodyne [view] Start in2017_t01 Aerodyne restarted.
IN2017_T01 2017-09-30 23:24 [view ] -9.2617 144.2133 Underway morgane perron Hydrochem Lab : uwy004 Sample Hydrochem_in2017_t01
IN2017_T01 2017-09-30 23:43 [view ] -9.2490 144.1514 MAAP [view] restarted in2017_t01 Restarted system numerous times to try clear error.
IN2017_T01 2017-10-01 01:27 [view ] -9.2449 143.8185 MAAP [view] Stop in2017_t01 MAAP cannot restart. Water degradation on sampling paper.
IN2017_T01 2017-10-01 03:46 [view ] -9.4554 143.5091 Drop keel [view] Raised in2017_t01 both drop keels to flush with hull for transit
IN2017_T01 2017-10-01 03:47 [view ] -9.4574 143.5073 Instrument Clean Seawater pump [view] Stop in2017_t01 Pump stopped due to keel flush with hull.
IN2017_T01 2017-10-01 03:47 [view ] -9.4594 143.5054 General Clean Seawater pump [view] Stop in2017_t01 Pump stopped due to keel flush with hull.
IN2017_T01 2017-10-01 03:48 [view ] -9.4594 143.5054 Trace Metal Pump [view] in2017_t01 Pump stopped due to keel flush with hull.
IN2017_T01 2017-10-01 03:48 [view ] -9.4615 143.5036 TSG [view] Stop in2017_t01 Due to pump stopping.
IN2017_T01 2017-10-01 03:49 [view ] -9.4615 143.5036 pCO2 [view] Stop in2017_t01 Due to pump stopping.
IN2017_T01 2017-10-01 03:54 [view ] -9.4715 143.4945 Fluorometer [view] Stop in2017_t01 Due to pump stopping.
IN2017_T01 2017-10-01 03:54 [view ] -9.4715 143.4945 Optode [view] Stop in2017_t01 Due to pump stopping.
IN2017_T01 2017-10-01 08:38 [view ] -10.1892 142.9467 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst013.asvp
IN2017_T01 2017-10-01 15:07 [view ] -10.5992 141.8512 Drop keel [view] Change in2017_t01 drop keel changed to 2m
IN2017_T01 2017-10-01 15:14 [view ] -10.6000 141.8400 CPR [view] Linda Gaskell Deployed in2017_t01 CPR 1 deployed
IN2017_T01 2017-10-01 15:15 [view ] -10.5999 141.8352 TSG [view] Start in2017_t01 Drop keels lowered, pumps started.
IN2017_T01 2017-10-01 15:15 [view ] -10.5999 141.8352 Optode [view] Start in2017_t01 Drop keels lowered, pumps started.
IN2017_T01 2017-10-01 15:15 [view ] -10.5999 141.8352 Fluorometer [view] Start in2017_t01 Drop keels lowered, pumps started.
IN2017_T01 2017-10-01 15:15 [view ] -10.5999 141.8352 pCO2 [view] Start in2017_t01 Drop keels lowered, pumps started.
IN2017_T01 2017-10-01 15:21 [view ] -10.6008 141.8157 General Clean Seawater pump [view] Start in2017_t01 pumps turned back on with drop keel extension
IN2017_T01 2017-10-01 15:23 [view ] -10.6009 141.8124 Instrument Clean Seawater pump [view] Start in2017_t01 pumps turned back on with drop keel extension
IN2017_T01 2017-10-01 15:23 [view ] -10.6011 141.8090 Trace Metal Pump [view] Start in2017_t01 pumps turned back on with drop keel extension
IN2017_T01 2017-10-01 16:43 [view ] -10.6131 141.5340 Aerodyne [view] restarted in2017_t01 75 restart hung on last restart.
IN2017_T01 2017-10-01 16:49 [view ] -10.6138 141.5166 ADCP [view] restarted in2017_t01 75 restart hung confirmation required with 150 not available
IN2017_T01 2017-10-01 18:07 [view ] -10.6259 141.2415 CCN [view] restarted in2017_t01 Restarted after reset from No CCN counts error.
IN2017_T01 2017-10-02 02:47 [view ] -10.7026 139.4850 Underway Morgane Perron Hydrochem Lab : uwy005 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-02 07:59 [view ] -10.7486 138.4353 Underway morgane perron Hydrochem Lab : uwy006 Sample Hydrochem_in2017_t01 TM underway
IN2017_T01 2017-10-02 08:00 [view ] -10.7487 138.4320 Underway morgane perron Hydrochem Lab : uwy007 Sample Hydrochem_in2017_t01 Contaminated sample
IN2017_T01 2017-10-02 10:11 [view ] -10.7676 138.0003 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst014.asvp
IN2017_T01 2017-10-02 15:23 [view ] -10.8129 136.9633 Ozone [view] outage in2017_t01 pump turned off to drain condensation
IN2017_T01 2017-10-02 21:49 [view ] -11.0895 135.6857 Underway morgane perron Hydrochem Lab : uwy008 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-02 22:11 [view ] -11.1062 135.6190 CCTV Stop in2017_t01 Side Science Area Camera returned to normal operation.
IN2017_T01 2017-10-02 23:00 [view ] Other [view] restarted in2017_t01 IT-GP3 rebooted itself
IN2017_T01 2017-10-02 23:17 [view ] -11.1593 135.4073 Techsas1 [view] restarted in2017_t01 after crash Down between 2250 and 2317
IN2017_T01 2017-10-03 00:41 [view ] -11.2277 135.1328 Underway Cassie Schwanger Hydrochem Lab : uwy009 Sample Hydrochem_in2017_t01 This sample was collected to coincide with a jump in fluroescence.
IN2017_T01 2017-10-03 02:34 [view ] -11.3200 134.7600 CPR [view] Linda Gaskell Retrieved in2017_t01 CPR 1 retrieved
IN2017_T01 2017-10-03 03:00 [view ] -11.3397 134.6844 Drop keel [view] Raised in2017_t01 Port flush with gondola, Stbd flush with hull for survey.
IN2017_T01 2017-10-03 03:00 [view ] -11.3397 134.6844 ADCP [view] Stop in2017_t01 Macumba search 12 Hours for search
IN2017_T01 2017-10-03 03:15 [view ] -11.3475 134.6533 Underway Cassie Schwanger Hydrochem Lab : uwy010, uwy011 Sample Hydrochem_in2017_t01 These samples were collected to determine if there was any difference in uwy system and trace metal in the underway seawater lab
IN2017_T01 2017-10-03 03:19 [view ] -11.3512 134.6375 EM710 [view] Start GSM_in2017_t01 2nm start Macumba run-in 2nm start Macumba run-in
IN2017_T01 2017-10-03 14:01 [view ] -11.3681 134.5997 SBP [view] Start GSM_in2017_t01 Start pinging/logging sbp120 Fuse blew on initial startup
IN2017_T01 2017-10-03 14:15 [view ] -11.3738 134.6048 EM710 [view] GSM_in2017_t01 Found Macumba! Macumba found in position 11°22.4255713& 39;S 136°36.4863701& 39;E
IN2017_T01 2017-10-03 21:47 [view ] -11.1602 134.0769 Ozone [view] restarted in2017_t01 Ozone 1 no reading. Power Cycle and running again.
IN2017_T01 2017-10-03 21:49 [view ] -11.1580 134.0706 TSG [view] maintenance in2017_t01 Cleaned Filter.
IN2017_T01 2017-10-03 22:00 [view ] -11.1500 134.0470 Drop keel [view] Lowered in2017_t01 Port drop keel to 2m. Stbd flush with hull.
IN2017_T01 2017-10-03 23:08 [view ] -11.0812 133.8447 ADCP [view] restarted in2017_t01 75kHz-post Macumba search
IN2017_T01 2017-10-04 00:26 [view ] -10.9971 133.5976 Underway morgane perron Hydrochem Lab : uwy012 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-04 05:42 [view ] -10.8588 132.5768 Underway Cassie Schwanger Hydrochem Lab : uwy013 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-04 12:13 [view ] -11.0370 131.2512 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst015.asvp SST= 29.0C
IN2017_T01 2017-10-04 15:37 [view ] -11.1141 130.6977 SBP [view] Start GSM_in2017_t01 Start logging SBP on sediment core site
IN2017_T01 2017-10-04 16:32 [view ] -11.0562 130.6059 Underway morgaqne perron Hydrochem Lab : uwy014 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-04 17:11 [view ] -10.9900 130.5000 CPR [view] Linda Gaskell Deployed in2017_t01 CPR 2 deployed
IN2017_T01 2017-10-04 23:17 [view ] -11.1278 129.4076 Underway Morgane Perron Hydrochem Lab : uwy015 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-04 23:23 [view ] -11.1341 129.3925 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst016.asvp New SVP applied in2017_t01_sst016.asvp sst = 29.5 sal = 34.5
IN2017_T01 2017-10-05 02:18 [view ] Other [view] Reboot in2017_t01 influx VM
IN2017_T01 2017-10-05 02:39 [view ] -11.3822 128.8003 Other [view] restarted in2017_t01 shipnav on Techsas1 Down between 0047 and 0239
IN2017_T01 2017-10-05 04:38 [view ] -11.5294 128.4486 Air Chemistry [view] maintenance in2017_t01 Manifold T&RH fixed The regex capturing the HMT317 data was not set up to handle humidities above 99.9%. I have corrected this.
IN2017_T01 2017-10-05 05:00 [view ] -11.5548 128.3879 Aerosol Lab [view] maintenance in2017_t01 Manifold T&RH sensor modification I made a change to the manifold code to handle RH >= 100%, and tried to restart it but it has hung :( Hopefully it will kick on, but otherwise a manual restart by someone on the ship may be required.
IN2017_T01 2017-10-05 08:50 [view ] -11.8487 127.6851 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst017.asvp SST= 30.1
IN2017_T01 2017-10-05 12:46 [view ] -12.1615 126.9363 Underway morgane perron Hydrochem Lab : uwy016 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-05 14:20 [view ] -12.2833 126.6444 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst018.asvp
IN2017_T01 2017-10-05 16:35 [view ] -11.1100 130.7000 Coring Linda Gaskell Deployed in2017_t01 Box corer 1 - 2 x Small Box Corer deployments
IN2017_T01 2017-10-06 02:52 [view ] -13.2800 124.5256 Underway Morgane Perron Hydrochem Lab : uwy017 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-06 03:04 [view ] -13.2900 124.5000 CPR [view] Linda Gaskell Retrieved in2017_t01 CPR 2 retrieved - silk damaged
IN2017_T01 2017-10-06 03:30 [view ] -13.3300 124.4100 Coring Deployed in2017_t01 Box corer 2 - 3 x Small Box Corer deployments
IN2017_T01 2017-10-06 05:34 [view ] -13.3439 124.2218 Ozone [view] maintenance in2017_t01 Ozone 1, high readin. Empty water trap, power cycle and running again.
IN2017_T01 2017-10-06 05:45 [view ] -13.3459 124.1841 TSG [view] maintenance in2017_t01 Cleaned Filter.
IN2017_T01 2017-10-06 05:45 [view ] -13.3462 124.1806 pCO2 [view] maintenance in2017_t01 Cleaned Filter.
IN2017_T01 2017-10-06 11:13 [view ] -13.5824 123.0951 EM710 [view] Other GSM_in2017_t01 Frequency range set to 40-100kHz
IN2017_T01 2017-10-06 11:19 [view ] -13.5881 123.0723 SBP [view] Stop GSM_in2017_t01 Stop pinging- interference with EM710
IN2017_T01 2017-10-06 11:32 [view ] -13.5971 123.0380 ADCP [view] Stop in2017_t01 stopped os75 for multibeam noise check
IN2017_T01 2017-10-06 11:37 [view ] -13.5974 123.0382 ADCP [view] Start in2017_t01 os75 turned back on
IN2017_T01 2017-10-06 11:39 [view ] -13.5975 123.0383 EM710 [view] Other GSM_in2017_t01 Restart SIS on sediment core station due to gridding failure
IN2017_T01 2017-10-06 11:50 [view ] -13.5986 123.0392 SBP [view] Start GSM_in2017_t01 Start logging SBP on sediment core site
IN2017_T01 2017-10-06 13:11 [view ] -13.6099 123.0489 EM710 [view] Start GSM_in2017_t01 Start logging EM710
IN2017_T01 2017-10-06 13:22 [view ] -13.6317 123.0296 Underway morgane Hydrochem Lab : uwy018 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-06 13:30 [view ] -13.6000 123.0400 Coring Deployed in2017_t01 Box corer 3 - 4 x Small Box Corer deployments
IN2017_T01 2017-10-06 13:31 [view ] -13.6538 123.0090 ADCP [view] Stop in2017_t01 ADCP stopped for swath line
IN2017_T01 2017-10-06 13:40 [view ] -13.6760 122.9885 ADCP [view] in2017_t01 os75 turned back on
IN2017_T01 2017-10-06 14:29 [view ] -13.7867 122.8804 TSG [view] restarted in2017_t01 reboot deck display not displaying correctly
IN2017_T01 2017-10-06 14:33 [view ] -13.7953 122.8709 XBT [view] Drop GSM_in2017_t01 XBT drop 002 Drop 2 failed, drop 3 used to create in2017_vt02_xbt002.asvp
IN2017_T01 2017-10-06 14:33 [view ] -13.7975 122.8684 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_xbt002.asvp
IN2017_T01 2017-10-06 16:51 [view ] -14.1131 122.5598 EM122 [view] Start GSM_in2017_t01 Start logging EM122
IN2017_T01 2017-10-06 16:51 [view ] -14.1155 122.5576 EM710 [view] Crash GSM_in2017_t01 EM710 crash
IN2017_T01 2017-10-06 16:54 [view ] -14.1227 122.5509 SBP [view] Stop GSM_in2017_t01 Stop pinging SBP
IN2017_T01 2017-10-06 16:56 [view ] -14.1251 122.5486 EM710 [view] Depth Mode GSM_in2017_t01 Forced to very deep ping mode to prevent ADCP interference
IN2017_T01 2017-10-06 16:57 [view ] -14.1276 122.5464 EM122 [view] Stop GSM_in2017_t01 Stop EM122
IN2017_T01 2017-10-06 17:30 [view ] -14.2200 122.4600 Coring Deployed in2017_t01 Box corer 4 - 6 x Small Box Corer deployments
IN2017_T01 2017-10-06 17:38 [view ] -14.2158 122.4630 SBP [view] Start GSM_in2017_t01 Start logging SBP on sediment core site
IN2017_T01 2017-10-06 23:25 [view ] -14.7898 122.2374 VSAT Recovered in2017_t01 change to beam 57E
IN2017_T01 2017-10-06 23:57 [view ] -14.8706 122.2056 Underway Morgane Perron Hydrochem Lab : uwy019 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-07 03:31 [view ] -15.3181 122.0291 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst019.asvp New SVP applied in2017_t01_sst019.asvp sst = 27.3 sal = 34.6
IN2017_T01 2017-10-07 06:45 [view ] -15.7394 121.8600 EM710 [view] SVP GSM_in2017_t01 New SVP applied in2017_t01_sst020.asvp SST= 27.8C
IN2017_T01 2017-10-07 08:41 [view ] -15.9176 121.7890 Underway Morgane Perron Hydrochem Lab : uwy020 Sample Hydrochem_in2017_t01
IN2017_T01 2017-10-07 16:46 [view ] -16.9802 121.7249 SBP [view] Stop GSM_in2017_t01
IN2017_T01 2017-10-07 16:50 [view ] -16.9862 121.7267 ADCP [view] Stop in2017_t01 stopped os75 coming into broome - very shallow
IN2017_T01 2017-10-07 16:50 [view ] -16.9862 121.7267 EK60 [view] Stop GSM_in2017_t01 Stop EK60
IN2017_T01 2017-10-07 23:40 [view ] -17.7157 121.9369 Trace Metal Rosette [view] Stop in2017_t01 Raing Drop Keel to flush with Hull.
IN2017_T01 2017-10-07 23:41 [view ] -17.7143 121.9366 Instrument Clean Seawater pump [view] Stop in2017_t01 Raing Drop Keel to flush with Hull.
IN2017_T01 2017-10-07 23:41 [view ] -17.7143 121.9366 General Clean Seawater pump [view] Stop in2017_t01 Raing Drop Keel to flush with Hull.
IN2017_T01 2017-10-07 23:41 [view ] -17.7128 121.9364 TSG [view] Stop in2017_t01 Pump stopped.
IN2017_T01 2017-10-07 23:42 [view ] -17.7128 121.9364 pCO2 [view] Stop in2017_t01 Pump stopped.
IN2017_T01 2017-10-07 23:42 [view ] -17.7128 121.9364 Fluorometer [view] Stop in2017_t01 Pump stopped.
IN2017_T01 2017-10-07 23:42 [view ] -17.7113 121.9362 Optode [view] Stop in2017_t01 Pump stopped.
IN2017_T01 2017-10-08 00:00 [view ] -17.6891 121.9334 Drop keel [view] Raised in2017_t01 Port drop keel raised to flush with hull. Both now flush with hull.
IN2017_T01 2017-10-08 01:32 [view ] -17.9043 121.9987 Radon detector [view] calibration in2017_t01 Started Calibration, set background for 1600.
IN2017_T01 2017-10-08 03:24 [view ] -18.0015 122.2192 EM710 [view] Stop GSM_in2017_t01 Stop logging at port
IN2017_T01 2017-10-08 04:00 [view ] Voyage Stop in2017_t01 Investigator arrives in Broome

Save this list as

NCMI Information and Data Centre  »  Applications  »  Data Trawler