Survey | When (UTC) | Latitude | Longitude | Instrument | Identifier | Action | Log | Subject / Comments |
---|---|---|---|---|---|---|---|---|
IN2015_C02 | 2015-11-30 01:50 [view ] | -34.7626 | 136.2308 | Techsas [view] | Start | in2015_c02 | Techsas started- T1 :21:25:30 T2: 21:32:00 29/11/2015 | |
IN2015_C02 | 2015-11-30 01:53 [view ] | -34.7712 | 136.2359 | ADCP [view] | Start | in2015_c02 | ADCP start 00:39 30/11/2015 | |
IN2015_C02 | 2015-11-30 01:56 [view ] | -34.7783 | 136.2405 | EM710 [view] | Start | GSM_in2015_c02 | Start Logging EM710 Start Logging EM710 Line 0000 | |
IN2015_C02 | 2015-11-30 03:27 [view ] | -35.0512 | 136.3367 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst001.asvp SST = 17 deg C Applied to EM710 and EM122 | |
IN2015_C02 | 2015-11-30 08:08 [view ] | -35.8355 | 136.4565 | EK60 [view] | Stop | GSM_in2015_c02 | End of Transect Transect 6 Site 1 end of transect | |
IN2015_C02 | 2015-11-30 11:40 [view ] | -35.8567 | 136.4510 | EK60 [view] | Start | GSM_in2015_c02 | Deploy EZ net Deploy EZ net vessel proceeding towards transect 6 site 2 | |
IN2015_C02 | 2015-11-30 14:34 [view ] | -36.0427 | 136.3360 | EK60 [view] | Stop | GSM_in2015_c02 | Transect 6 Site 2 Transect 6 Site 2, stopped for CTD | |
IN2015_C02 | 2015-11-30 15:28 [view ] | -36.0583 | 136.3223 | EK60 [view] | Start | GSM_in2015_c02 | Transit to Transect 6 Site 3 | |
IN2015_C02 | 2015-11-30 15:56 [view ] | -36.1366 | 136.2805 | TSG [view] | outage | in2015_c02 | TSG needed restarting as no data was coming through Techsas | |
IN2015_C02 | 2015-11-30 16:37 [view ] | -36.2445 | 136.2172 | EK60 [view] | Stop | GSM_in2015_c02 | Transect 6 Site 3 Transect 6, Site 3 Stopped for CTD | |
IN2015_C02 | 2015-11-30 17:07 [view ] | -36.2458 | 136.2185 | EK60 [view] | Start | GSM_in2015_c02 | Transect 6 Site 4 (start cross shelf transect) | |
IN2015_C02 | 2015-11-30 17:23 [view ] | -36.2838 | 136.1947 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst002.asvp SST = 16.7 Salinity= 35.7 | |
IN2015_C02 | 2015-11-30 18:04 [view ] | -36.3893 | 136.1278 | SST [view] | outage | in2015_c02 | SST sensor was not sending data- it was restarted and came good | |
IN2015_C02 | 2015-11-30 18:21 [view ] | -36.4240 | 136.1053 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 1500m | |
IN2015_C02 | 2015-11-30 18:26 [view ] | -36.4367 | 136.0963 | EM710 [view] | Stop | GSM_in2015_c02 | Stop logging and pinging EM710 and EM122 turned off to optimize EK60 data off shelf | |
IN2015_C02 | 2015-11-30 18:46 [view ] | -36.4855 | 136.0665 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 3000m Transect 6 Site 4-5 | |
IN2015_C02 | 2015-11-30 20:59 [view ] | -36.7500 | 135.8880 | Gravity Meter [view] | Stop | GSM_in2015_c02 | Gravity meter clamped and shut down due to rough weather | |
IN2015_C02 | 2015-12-01 00:54 [view ] | -37.1928 | 135.6090 | EK60 [view] | Stop | GSM_in2015_c02 | End of Transect line 6 (cross shelf transect) | |
IN2015_C02 | 2015-12-01 04:34 [view ] | -37.2950 | 135.4852 | EK60 [view] | Start | GSM_in2015_c02 | Transect 6, vessel changed course 180° at end of transect line | |
IN2015_C02 | 2015-12-01 09:11 [view ] | -37.1337 | 135.7590 | EK60 [view] | Other | GSM_in2015_c02 | Power Settings Noted power setting not set as per instruction 38KHz - 4000W changed to 2000W 200KHz - 150W changed to 105W 333KHz - 50W changed to 40W | |
IN2015_C02 | 2015-12-01 11:24 [view ] | -37.1883 | 135.7063 | EK60 [view] | Other | GSM_in2015_c02 | EZ Net deployed | |
IN2015_C02 | 2015-12-01 13:30 [view ] | -37.2430 | 135.6420 | Other [view] | Start | GSM_in2015_c02 | CTD at Transect 6 Site 8 | |
IN2015_C02 | 2015-12-01 15:42 [view ] | -37.1952 | 135.6962 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst003.asvp SST= 15.7 | |
IN2015_C02 | 2015-12-01 18:48 [view ] | -37.2657 | 135.5968 | Other [view] | Start | GSM_in2015_c02 | CTD at Transect 6 Site 8 | |
IN2015_C02 | 2015-12-02 00:34 [view ] | -37.2692 | 135.5537 | EM122 [view] | Start | GSM_in2015_c02 | Start logging EM122 Transect 6 Site 8 | |
IN2015_C02 | 2015-12-02 02:35 [view ] | -37.2982 | 135.4577 | EM122 [view] | Stop | GSM_in2015_c02 | Stop logging EM122; PAOS being deployed | |
IN2015_C02 | 2015-12-02 03:11 [view ] | -37.3010 | 135.4590 | EK60 [view] | Start | GSM_in2015_c02 | pAOS in water Will see interference in EK60 data | |
IN2015_C02 | 2015-12-02 05:58 [view ] | -37.1860 | 135.5630 | Other [view] | Start | GSM_in2015_c02 | MIDOC in water | |
IN2015_C02 | 2015-12-02 08:16 [view ] | -37.2313 | 135.4500 | Other [view] | Stop | GSM_in2015_c02 | Trawl completed, recover to deck | |
IN2015_C02 | 2015-12-02 08:24 [view ] | -37.2340 | 135.4436 | CTD [view] | Repair | in2015_c02 | CTD Altimeter calibration correction The CTD calibration coefficients for the PA500 Altimeter were incorrectly set. a1 was -0.02442 instead of -0.01221. This has been corrected. The correct values for this altimeter are: a0 = 50 a1 = -0.01221 This error was evident on IN2015_V02 but not explained or corrected at the time. See the IN2015_V02 Instrumentation report for a plot of this. | |
IN2015_C02 | 2015-12-02 11:04 [view ] | -36.9882 | 135.7875 | Other [view] | Start | GSM_in2015_c02 | Deploy AOS Profiler | |
IN2015_C02 | 2015-12-02 17:17 [view ] | -36.6422 | 135.9870 | EK60 [view] | Start | GSM_in2015_c02 | Re-synchronized in Ksync Settings changed based on feedback from Simrad. EK60, EM122 and ADCP now synchrinized in a single group. EK60 set to 1s in runtime parameters. Installation parameters changed to uncheck Transmitting signal , SIgnal active was set to Active High and Pulse length set to 10ms. EK60 is set to maximise pinging. All systems now seem to be synchronized with EK60 pinging at a maximal rate (~5s) | |
IN2015_C02 | 2015-12-02 17:21 [view ] | -36.6320 | 135.9923 | EM122 [view] | Start | GSM_in2015_c02 | Start logging and pinging EM122 Transect 6 Site 5 | |
IN2015_C02 | 2015-12-02 17:38 [view ] | -36.5955 | 136.0138 | Gravity Meter [view] | Start | GSM_in2015_c02 | Gravity meter turned back on (calmer weather) | |
IN2015_C02 | 2015-12-02 17:43 [view ] | -36.5963 | 136.0145 | Other [view] | Start | GSM_in2015_c02 | CTD at Transect 6 Site 5 | |
IN2015_C02 | 2015-12-02 19:36 [view ] | -36.5945 | 136.0045 | EM122 [view] | Stop | GSM_in2015_c02 | Stop logging EM122 Transect 6 Station 5 net deployments | |
IN2015_C02 | 2015-12-02 21:35 [view ] | -36.5892 | 136.0025 | ME70 [view] | Start | GSM_in2015_c02 | Start pinging and loggin ME70 Ksync- maximized pinging, in same group as EK60, EM122, ADCP150 | |
IN2015_C02 | 2015-12-02 21:53 [view ] | -36.5795 | 135.9895 | EM122 [view] | Start | GSM_in2015_c02 | Start logging EZ net tow | |
IN2015_C02 | 2015-12-03 00:24 [view ] | -36.5750 | 135.9892 | EM122 [view] | Stop | GSM_in2015_c02 | Stop logging EM122; PAOS being deployed | |
IN2015_C02 | 2015-12-03 01:23 [view ] | -36.5743 | 135.9783 | EK60 [view] | Depth Mode | GSM_in2015_c02 | change range to 1500 | |
IN2015_C02 | 2015-12-03 01:38 [view ] | -36.5710 | 135.9765 | EK60 [view] | Line | GSM_in2015_c02 | Cross shelf transect from from station 5 to 200 m Running from station 5 towards station 4 and beyond up to 200 m depth. | |
IN2015_C02 | 2015-12-03 16:52 [view ] | -36.4547 | 136.0882 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst004.asvp SST=16.4 C | |
IN2015_C02 | 2015-12-03 16:53 [view ] | -36.4552 | 136.0887 | EM122 [view] | Start | GSM_in2015_c02 | Start logging EM122 on EZ net line | |
IN2015_C02 | 2015-12-03 18:46 [view ] | -36.4485 | 136.0837 | EK60 [view] | Start | GSM_in2015_c02 | Turbo map fast temperature probe, changed settings Logging range set to 200m; Ping mode set to internal maximum; Maximizing ping rate and resolution to be able to compare with high resolution sensors on Turbo map fast sampling high resolution temperature probe. 18 kHz Pulse 0.512 ms, Power 2000 W 38 kHz Pulse 0.256 ms, Power 2000 W 70 kHz Pulse 0.128 ms, Power 750 W 120 kHz Pulse 0.256 ms, Power 250 W 200 kHz Pulse 1.024 ms, Power 105 W 333 kHz Pulse 1.024 ms, Power 40 W Logging range 200 m. Ping repitition rate - various to adjust 18 kHz multiple reflection out of the echogram. | |
IN2015_C02 | 2015-12-03 18:58 [view ] | -36.4482 | 136.0830 | EM122 [view] | Stop | GSM_in2015_c02 | Stop logging at CTD site | |
IN2015_C02 | 2015-12-03 19:00 [view ] | -36.4480 | 136.0831 | CTD [view] | CTD10 | Deployed | in2015_c02 | CTD wire broke on start of deployment CTD was mostly within the ship |
IN2015_C02 | 2015-12-03 19:26 [view ] | -36.4477 | 136.0785 | EK60 [view] | GSM_in2015_c02 | EM122 and ME70 stopped pinging to reduce EK60 interference | ||
IN2015_C02 | 2015-12-03 20:17 [view ] | -36.4483 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Settings changed back to default, logging to 1000m Logging to 1000m, All settings changed back to defalut | ||
IN2015_C02 | 2015-12-03 23:14 [view ] | -36.4513 | 136.0883 | EK60 [view] | Other | GSM_in2015_c02 | pAOS in water | |
IN2015_C02 | 2015-12-03 23:51 [view ] | -36.4502 | 136.0873 | EK60 [view] | Stop | GSM_in2015_c02 | pAOS recovered | |
IN2015_C02 | 2015-12-04 00:23 [view ] | -36.4492 | 136.0858 | EK60 [view] | Start | GSM_in2015_c02 | Site 4 Cross shelf transect D20151204-T002629 | |
IN2015_C02 | 2015-12-04 00:27 [view ] | -36.4477 | 136.0868 | EM122 [view] | Start | GSM_in2015_c02 | Start logging Em122 Site 4 Acoustic transect | |
IN2015_C02 | 2015-12-04 01:05 [view ] | -36.4183 | 136.1078 | EK60 [view] | Start | GSM_in2015_c02 | Site 4 Cross shelf Transect reciprocal | |
IN2015_C02 | 2015-12-04 02:00 [view ] | -36.4470 | 136.0880 | EK60 [view] | Stop | GSM_in2015_c02 | end recipricol cross shelf transect | |
IN2015_C02 | 2015-12-04 02:04 [view ] | -36.4473 | 136.0883 | Other [view] | Start | GSM_in2015_c02 | CTD at Transect 6 Site 4 | |
IN2015_C02 | 2015-12-04 17:08 [view ] | -35.2855 | 134.4778 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 1200m | |
IN2015_C02 | 2015-12-04 17:58 [view ] | -35.1967 | 134.3262 | EM122 [view] | Crash | GSM_in2015_c02 | EM122 crash EM122 stopped responding to external trigger, but could be triggered internally. SIS restarted with no luck. EM122 transducer turned off and on but did not fix problem. Beam spacing mode was changed to HD EQDST and would then recieve Ksync external triggers and ping | |
IN2015_C02 | 2015-12-04 19:05 [view ] | -35.0750 | 134.1325 | EM710 [view] | Start | GSM_in2015_c02 | Start logging and pinging EM710 | |
IN2015_C02 | 2015-12-04 20:06 [view ] | -35.0397 | 134.0704 | EK60 [view] | Stop | GSM_in2015_c02 | End of cross shelf transect | |
IN2015_C02 | 2015-12-04 21:15 [view ] | -35.0312 | 134.0750 | Other [view] | Start | GSM_in2015_c02 | Start Beam Trawl recon line EM122= 0038 EM710= 0026 | |
IN2015_C02 | 2015-12-04 21:36 [view ] | -35.0410 | 135.0937 | Other [view] | Stop | GSM_in2015_c02 | End swath recon line EM122= 0039 EM710=0027 | |
IN2015_C02 | 2015-12-04 23:27 [view ] | -35.0350 | 134.0883 | Other [view] | Start | GSM_in2015_c02 | Beam trawl T5 200m Water column logging on Em122 and EM710 EM122= 0040 EM710= 0028 | |
IN2015_C02 | 2015-12-05 00:56 [view ] | -35.0893 | 134.0810 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 1200m | |
IN2015_C02 | 2015-12-05 22:44 [view ] | -35.8283 | 134.0758 | EK60 [view] | Start | GSM_in2015_c02 | T5 to T4 along shelf transect K sync settings: EK60= 2s; Em122= external; ADCP= 1s | |
IN2015_C02 | 2015-12-06 00:55 [view ] | -35.8315 | 133.7835 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_ctd002.asvp | |
IN2015_C02 | 2015-12-06 21:49 [view ] | -35.2718 | 132.6953 | EK60 [view] | Other | GSM_in2015_c02 | Logging range set to 250m and pulse lengths shortened Settings changed to optimize individual targets | |
IN2015_C02 | 2015-12-06 21:57 [view ] | -35.2718 | 132.6953 | EK60 [view] | Other | GSM_in2015_c02 | Logging range set to 100m Settings changed to optimize individual targets | |
IN2015_C02 | 2015-12-06 22:10 [view ] | -35.2597 | 132.6962 | EK60 [view] | Other | GSM_in2015_c02 | Logging range set back to 1500m, pulse lengths returned to default | |
IN2015_C02 | 2015-12-06 22:56 [view ] | -35.2104 | 132.6928 | TSG [view] | Deployed | in2015_c02 | TSG Calibration 1 | |
IN2015_C02 | 2015-12-07 00:31 [view ] | -35.0300 | 132.6823 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst006.asvp SST=17.2 | |
IN2015_C02 | 2015-12-07 15:57 [view ] | -34.2777 | 132.5850 | EK60 [view] | Other | GSM_in2015_c02 | Fast Ping: Logging set to 100m, pulse lengths shortened Other sonars and ADCP turned off | |
IN2015_C02 | 2015-12-07 16:29 [view ] | -34.2802 | 132.5852 | EK60 [view] | Other | GSM_in2015_c02 | End of Fast Ping- all settings back to normal Logging range = 600m | |
IN2015_C02 | 2015-12-07 16:51 [view ] | -34.2772 | 132.6187 | EM122 [view] | warning | GSM_in2015_c02 | EM122 giving errors and not pinging properly Error: No response from echosounder at start of pinging, sounder type EM122 Serial number 122. Try to turn off pinging and on (524) Not syncing in Ksync Only showing aplitude detection, data in a parabola, not tracking bottom Turned off and on and cannot get to properly track or sycnhonize pinging. Turning off until in deeper water | |
IN2015_C02 | 2015-12-07 17:51 [view ] | -34.2703 | 132.6863 | EM710 [view] | SVP | GSM_in2015_c02 | SVP changed to in2015_c02_sst008.asvp | |
IN2015_C02 | 2015-12-07 20:55 [view ] | -34.2767 | 132.6882 | EK60 [view] | Start | GSM_in2015_c02 | Start Zig Zag Transect from T4 | |
IN2015_C02 | 2015-12-08 01:30 [view ] | -34.0845 | 132.2895 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping- logging range set to 100m, pulse lengths shortened | |
IN2015_C02 | 2015-12-08 01:52 [view ] | -34.0703 | 132.2867 | EK60 [view] | Stop | GSM_in2015_c02 | Fast ping finished- settings back to default, logging range 750m | |
IN2015_C02 | 2015-12-08 05:26 [view ] | -33.7656 | 131.8849 | ADCP [view] | restarted | in2015_c02 | ADCP external trigger restarted GSM noted that the external triggering for the ADCP had been switched off - it has now been restarted. It is unknown how long triggering as been off. | |
IN2015_C02 | 2015-12-08 15:58 [view ] | -33.4558 | 131.0248 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-08 16:05 [view ] | -33.4608 | 131.0252 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 750m | |
IN2015_C02 | 2015-12-08 17:25 [view ] | -33.6933 | 131.0422 | EK60 [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 1200m | |
IN2015_C02 | 2015-12-08 17:32 [view ] | -33.7113 | 131.0438 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 1 in2015_c02_xbt000.nc | |
IN2015_C02 | 2015-12-08 17:58 [view ] | -33.7943 | 131.0503 | EK60 [view] | Stop | GSM_in2015_c02 | EK60 12kHz set to passive Interference with EM122, Ek60 12kHz will be set to passive at 1000m depths in order to switch from the EM710 to EM122 | |
IN2015_C02 | 2015-12-08 19:30 [view ] | -33.9415 | 131.0600 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-08 19:42 [view ] | -33.9485 | 131.0602 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1200m | |
IN2015_C02 | 2015-12-08 21:17 [view ] | -33.9972 | 131.0602 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 2 in2015_c02_xbt001.nc | |
IN2015_C02 | 2015-12-08 22:53 [view ] | -34.1605 | 131.0645 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_xbt001.asvp | |
IN2015_C02 | 2015-12-08 23:01 [view ] | -34.1845 | 131.0650 | XBT [view] | Depth Mode | GSM_in2015_c02 | Logging range set to 1500m | |
IN2015_C02 | 2015-12-09 00:36 [view ] | -34.4085 | 131.0623 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 3 in2015_c02_xbt002.nc | |
IN2015_C02 | 2015-12-09 01:55 [view ] | -34.6173 | 131.0568 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-09 02:07 [view ] | -34.6237 | 131.0570 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-09 16:45 [view ] | -35.2397 | 131.0742 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-09 16:52 [view ] | -35.2397 | 131.0742 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-09 19:25 [view ] | -35.2325 | 131.0680 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened During morning plankton migration | |
IN2015_C02 | 2015-12-09 19:53 [view ] | -35.2302 | 131.0708 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-09 20:35 [view ] | -35.2578 | 131.0455 | EM122 [view] | warning | GSM_in2015_c02 | Persistent issues with EM122 start pinging EM122 having issues trying to start pinging after being stopped and linking to K-Sync. Error message: (Numb disp) Echo sounder EM122_122: PIng status is faulty. The echo sounder is pinging. Try to turn pinging on and off to correct problem. Also error: (DDS) No response from echosounder at start of pinging, sounder type: EM122, serial number: 122. Try to turn pinging off and on. | |
IN2015_C02 | 2015-12-09 22:03 [view ] | -35.2867 | 131.0148 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-09 22:15 [view ] | -35.2900 | 131.0113 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-10 00:53 [view ] | -35.3178 | 130.9905 | Other [view] | Stop | GSM_in2015_c02 | End of T3 | |
IN2015_C02 | 2015-12-10 05:20 [view ] | -35.0898 | 130.6863 | EK60 [view] | Stop | GSM_in2015_c02 | FAST PINGING Stop Logging Stop Logging, change to shallow fast ping mode. | |
IN2015_C02 | 2015-12-10 05:33 [view ] | -35.0898 | 130.6852 | EK60 [view] | Stop | GSM_in2015_c02 | Stop Fast pinging | |
IN2015_C02 | 2015-12-10 16:20 [view ] | -35.0310 | 130.3685 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-10 16:37 [view ] | -35.0292 | 130.3683 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-10 21:20 [view ] | -35.1638 | 130.6721 | ADCP [view] | Stop | in2015_c02 | GSM stop logging ADCP for EK60 tests | |
IN2015_C02 | 2015-12-10 21:21 [view ] | -35.1638 | 130.6718 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-10 21:54 [view ] | -35.1628 | 130.6777 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-10 23:20 [view ] | -35.1651 | 130.6938 | ADCP [view] | Start | in2015_c02 | GSM restart ADCP logging | |
IN2015_C02 | 2015-12-10 23:57 [view ] | -35.1790 | 130.6997 | EM122 [view] | Crash | GSM_in2015_c02 | EM122 will not start pinging, failed BIST tests, troubleshooting BIST tests failed. Restarted both PC and computer. BISTS passesd but still will not ping. Ran extended telnet BIST. Failed Preamplifier tests (51 and 53). TUrned off SBP, EM122 PC and transducer and then turned off preamplified. Turned back on and booted EM122 back up. Re-ran preamplifier BISTS. Still failed. Start pinging- shows pings being fired in Ksync but does not show pings in SIS. Telnet shows "No attitude" messages. Possibly a problem with the pre-amplifier unit so the pings are being sent but not properly recieved. | |
IN2015_C02 | 2015-12-11 03:04 [view ] | -35.2618 | 130.7191 | ADCP [view] | Stop | in2015_c02 | GSM stop logging ADCP for EK60 tests | |
IN2015_C02 | 2015-12-11 03:05 [view ] | -35.2617 | 130.7190 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-11 03:17 [view ] | -35.2617 | 130.7193 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-11 04:12 [view ] | -35.2540 | 130.7210 | Other [view] | Start | GSM_in2015_c02 | MIDOC in water MIDOC in water stn:247-252 water depth 3600m | |
IN2015_C02 | 2015-12-11 04:14 [view ] | -35.2528 | 130.7208 | EM122 [view] | Start | GSM_in2015_c02 | Restart logging EM122 _ fault finding. Shut all systems down apart from pre-amp. Tested voltage on TP17/18 on each pre-amp card, all acceptable and within range as per manual. Checked seating of TX cards in EM122 TRU, all appear ok. Restart system, initial error that ping status is faulty as before however ack this error restart pinging and system work ok. She lives to ping another day, as to the root cause of this problem , atm, no fecking idea. | |
IN2015_C02 | 2015-12-11 06:28 [view ] | -35.1248 | 130.6935 | Other [view] | Stop | GSM_in2015_c02 | end of MIDOC advance EK file number end of MIDOC advance EK file number MIDOC tow to 600 m Net 1 80 minutes o to 600 m Net 2 20 minutes 600 m to 400 m Net 3 10 minutes 400 to 300 m Net 4 10 minutes 300 to 200 minutes Net 5 10 minutes 200 to 100 minutes Net 6 10 minutes 100 to 0 m | |
IN2015_C02 | 2015-12-11 10:33 [view ] | -35.0688 | 130.6887 | Other [view] | Start | GSM_in2015_c02 | MIDO Night to 600 m | |
IN2015_C02 | 2015-12-11 10:35 [view ] | -35.0697 | 130.6888 | ADCP [view] | Start | in2015_c02 | ADCP restarted | |
IN2015_C02 | 2015-12-11 15:53 [view ] | -35.2123 | 130.6953 | EK60 [view] | Start | GSM_in2015_c02 | Fast Ping on station | |
IN2015_C02 | 2015-12-11 16:02 [view ] | -35.2068 | 130.6952 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-11 19:53 [view ] | -35.1541 | 130.7005 | ADCP [view] | Stop | in2015_c02 | GSM stop logging ADCP for EK60 tests | |
IN2015_C02 | 2015-12-11 19:57 [view ] | -35.1535 | 130.7051 | ADCP [view] | Start | in2015_c02 | GSM restart ADCP logging | |
IN2015_C02 | 2015-12-12 00:20 [view ] | -35.1808 | 130.5950 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-12 00:44 [view ] | -35.1580 | 130.5972 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-12 02:22 [view ] | -34.8835 | 130.6493 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 6 in2015_c02_xbt005.nc | |
IN2015_C02 | 2015-12-12 02:34 [view ] | -34.8493 | 130.6578 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_xbt003.asvp in2015_c02_xbt005.nc | |
IN2015_C02 | 2015-12-12 16:04 [view ] | -34.0278 | 130.6613 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 9 in2015_c02_008.nc | |
IN2015_C02 | 2015-12-12 17:21 [view ] | -33.7972 | 130.6710 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping: logging range set to 250m, pulse lengths shortened | |
IN2015_C02 | 2015-12-12 17:36 [view ] | -33.7972 | 130.6707 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-12 18:24 [view ] | -33.7978 | 130.6677 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_xbt004.asvp in2015_c02_xbt_008.nc (Drop 9) | |
IN2015_C02 | 2015-12-12 22:27 [view ] | -33.7140 | 130.6677 | EK60 [view] | Start | GSM_in2015_c02 | Fast Ping on ICP station | |
IN2015_C02 | 2015-12-12 22:35 [view ] | -33.7140 | 130.6678 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1200m | |
IN2015_C02 | 2015-12-13 03:13 [view ] | -33.4152 | 130.6660 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst010.asvp SST= 18.7 | |
IN2015_C02 | 2015-12-13 16:07 [view ] | -33.4183 | 130.7127 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping on EZ net line | |
IN2015_C02 | 2015-12-13 16:11 [view ] | -33.4184 | 130.7178 | ADCP [view] | Stop | in2015_c02 | GSM stop logging ADCP for EK60 tests | |
IN2015_C02 | 2015-12-13 16:17 [view ] | -33.4185 | 130.7215 | EK60 [view] | Stop | GSM_in2015_c02 | Stop Fast pinging | |
IN2015_C02 | 2015-12-13 16:18 [view ] | -33.4185 | 130.7222 | ADCP [view] | Start | in2015_c02 | GSM restart ADCP logging | |
IN2015_C02 | 2015-12-13 21:08 [view ] | -33.4228 | 130.6705 | EK60 [view] | Start | GSM_in2015_c02 | Fast Ping on station | |
IN2015_C02 | 2015-12-13 22:03 [view ] | -33.4210 | 130.6740 | EK60 [view] | Stop | GSM_in2015_c02 | Stop Fast pinging | |
IN2015_C02 | 2015-12-14 20:09 [view ] | -33.5510 | 130.6802 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping on CTD station | |
IN2015_C02 | 2015-12-14 21:32 [view ] | -33.5428 | 130.6880 | EK60 [view] | Stop | GSM_in2015_c02 | Stop Fast pinging | |
IN2015_C02 | 2015-12-15 00:47 [view ] | -33.5257 | 130.4557 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst011.asvp SST= 18.6 | |
IN2015_C02 | 2015-12-15 06:04 [view ] | -33.5277 | 130.2697 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping - start | |
IN2015_C02 | 2015-12-15 06:04 [view ] | -33.5277 | 130.2697 | EK60 [view] | Stop | GSM_in2015_c02 | Fast ping - end | |
IN2015_C02 | 2015-12-15 08:11 [view ] | -33.3819 | 130.2606 | Other [view] | Other | GSM_in2015_c02 | EK60 logging found turned off EK logging found turned off missing 1 hour of data started logging all functioning changed range to 700 m and ping interval 1.4 sec | |
IN2015_C02 | 2015-12-15 11:00 [view ] | -33.3690 | 130.2962 | Other [view] | Other | GSM_in2015_c02 | Changing range to 600 m | |
IN2015_C02 | 2015-12-15 12:53 [view ] | -33.3359 | 130.2790 | Other [view] | GSM_in2015_c02 | high ping rate short pulse range 200 m | ||
IN2015_C02 | 2015-12-15 15:21 [view ] | -33.3680 | 130.6543 | EK60 [view] | Start | GSM_in2015_c02 | swath line at 200 m change range 400 m | |
IN2015_C02 | 2015-12-15 16:17 [view ] | -33.3710 | 130.7912 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping - start | |
IN2015_C02 | 2015-12-15 16:52 [view ] | -33.3662 | 130.7408 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 250m | |
IN2015_C02 | 2015-12-15 19:31 [view ] | -33.1947 | 130.6563 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst0012.asvp | |
IN2015_C02 | 2015-12-15 21:35 [view ] | -33.0547 | 130.6502 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping on station | |
IN2015_C02 | 2015-12-15 21:48 [view ] | -33.0538 | 130.6503 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 250m | |
IN2015_C02 | 2015-12-16 03:43 [view ] | -33.2592 | -130.6328 | EK60 [view] | Depth Mode | GSM_in2015_c02 | EK60 Logging mode to 1500m EK60 Logging mode to 1500m | |
IN2015_C02 | 2015-12-16 08:12 [view ] | -33.5277 | 130.2654 | EK60 [view] | GSM_in2015_c02 | change range to 1000 m | ||
IN2015_C02 | 2015-12-16 09:51 [view ] | -33.3363 | 130.2766 | EK60 [view] | GSM_in2015_c02 | change to 1 msec puls | ||
IN2015_C02 | 2015-12-16 13:26 [view ] | -33.3551 | 130.3831 | EK60 [view] | Start | GSM_in2015_c02 | Turbo Map and cardinal TS change range to 200 and short pulse for turbo map exercise and cardinal TS | |
IN2015_C02 | 2015-12-16 15:57 [view ] | -33.4042 | 130.3497 | EM710 [view] | warning | GSM_in2015_c02 | PPS error (PU Sensor) 1PPS Clock Synch. on PU port 1PPS is missing. Restarted pinging several times until no longer had error. | |
IN2015_C02 | 2015-12-16 21:13 [view ] | -33.5817 | 130.2613 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 10 in2015_c02_xbt_009.nc | |
IN2015_C02 | 2015-12-16 21:31 [view ] | -33.6508 | 130.2287 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_xbt005.asvp XBT drop 10 | |
IN2015_C02 | 2015-12-16 22:51 [view ] | -33.8558 | 130.2553 | XBT [view] | Drop | GSM_in2015_c02 | Drop 11 in2015_c02_xbt_010.nc | |
IN2015_C02 | 2015-12-17 00:08 [view ] | -34.0637 | 130.2685 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping on beam trawl station | |
IN2015_C02 | 2015-12-17 00:38 [view ] | -34.0785 | 130.2537 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-17 00:42 [view ] | -34.0797 | 130.2525 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_xbt006.asvp in2015_c02_xbt010.nc | |
IN2015_C02 | 2015-12-17 06:32 [view ] | -34.2283 | 130.2550 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 12 in2015_c02_xbt_011.nc | |
IN2015_C02 | 2015-12-17 07:51 [view ] | -34.4533 | 130.2733 | XBT [view] | Drop | GSM_in2015_c02 | XBT drop 13 in2015_c02_xbt_012.nc | |
IN2015_C02 | 2015-12-17 17:19 [view ] | -34.6623 | 130.2798 | EK60 [view] | Start | GSM_in2015_c02 | Fast ping - start | |
IN2015_C02 | 2015-12-17 17:29 [view ] | -34.6678 | 130.2798 | EK60 [view] | Stop | GSM_in2015_c02 | Stop fast pings: all settings back to default, logging range to 1500m | |
IN2015_C02 | 2015-12-17 17:33 [view ] | -34.6693 | 130.2793 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst013.asvp SST= 18.2 | |
IN2015_C02 | 2015-12-18 01:43 [view ] | -34.7428 | 130.2162 | Other [view] | Stop | GSM_in2015_c02 | USBL system shut down Starboard drop keel will be raised | |
IN2015_C02 | 2015-12-18 02:48 [view ] | -34.7408 | 130.2172 | drop keel [view] | Raised | in2015_c02 | Port drop keel (ADCP, EK60 et al) raised to flush with gondola Starboard drop keel raised all the way. USBL systems shut off completely (switched off in aft transceiver room rack) to prevent accidental pinging with transducer out of the water. Drop keels will stay up en route to Fremantle | |
IN2015_C02 | 2015-12-18 03:12 [view ] | -34.7393 | 130.2182 | EM122 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst014.asvp | |
IN2015_C02 | 2015-12-20 00:09 [view ] | -35.2498 | 120.4559 | ADCP [view] | Reboot | in2015_c02 | ADCP 150 machine restarted The 150 was found to have red status for its NAV data @00 on 20/12/2015, it appeared that the machine had lost its network connection all together. Network servers couldn't be pinged from it. The host was restarted and it resolved the problem. | |
IN2015_C02 | 2015-12-20 17:21 [view ] | -35.2538 | 116.5310 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_sst017.asvp SST= 19.3 | |
IN2015_C02 | 2015-12-21 03:12 [view ] | -34.4025 | 114.7632 | EM710 [view] | SVP | GSM_in2015_c02 | New SVP in2015_c02_SST017.asvp SST=19.9 | |
IN2015_C02 | 2015-12-21 05:40 [view ] | -33.9514 | 114.7598 | TSG [view] | in2015_c02 | TSG 0194 interface An 0194 board TSG interface has been implemented. The TSG is now serially connected to an 0194 board (IP 150.229.233.238) which handles TSG configuration and sends data to Techsas at port 224.0.36.0:50033 via UDP. The process of implementing this caused a few brief TSG data outages and anomalies (including negative values recorded for a short period) over the past 24 hours. | ||
IN2015_C02 | 2015-12-21 11:39 [view ] | -33.0452 | 114.9560 | Ozone Detector [view] | Repair | in2015_c02 | The Ozone detector stopped reporting data a couple of days ago. Inspection showed the instrument had suffered an electrical fault. The instrument was repaired this afternoon and put back into operation around 0900 UTC 21/12/2015 | |
IN2015_C02 | 2015-12-21 22:15 [view ] | -31.9685 | 115.6450 | Other [view] | Stop | GSM_in2015_c02 | End of Voyage EM710 and EK60 stopped pinging and shut down for arrival at port. Port drop keel raised. |