Please login if you have access to particular applications.
Event details
Voyage: | IN2015_C02 [details] | ||||
Subject: | EM122 giving errors and not pinging properly | ||||
When: | 2015-12-07 16:51:30 UTC - entered into Elog/Everlog as 2015-12-07 16:51:30 | ||||
Log: | GSM_in2015_c02 | ||||
Equipment: | EM122
Kongsberg EM122 12kHz multibeam echo sounder [view] | ||||
Position: |
Latitude: -34.27717 Longitude: 132.61867
- entered into Elog as 34°16.63'S, 132°37.12'E | ||||
Action: | warning | ||||
| |||||
Comments: | Error: No response from echosounder at start of pinging, sounder type EM122 Serial number 122. Try to turn off pinging and on (524) Not syncing in Ksync Only showing aplitude detection, data in a parabola, not tracking bottom Turned off and on and cannot get to properly track or sycnhonize pinging. Turning off until in deeper water |