Please login if you have access to particular applications.
Event details
Voyage: | IN2017_V01 [details] | ||
Subject: | in2016_v01_xbt004_DORIS_edit | ||
When: | 2017-01-23 21:35:35 UTC - entered into Elog/Everlog as 2017-01-23 21:35:35 | ||
Log: | GSM_in2017_v01 | ||
Equipment: | EM122
Kongsberg EM122 12kHz multibeam echo sounder [view] | ||
Position: |
Latitude: -64.54983 Longitude: 116.05867
- entered into Elog as 64 32.99 S, 116 03.52 E | ||
Action: | SVP | ||
| |||
Comments: | Changed to in2016_v01_xbt004_DORIS_edit.asvp XBT004 dropped, XBT builder gave error that drop was bad (isothermal) however I believe this is representative of oceanographic conditions, so accepted data as good. Data processed with DORIS software. Remove data at end of drop and extended to 12000 and decimated with Douglas Peucker at 0.1. Export to .asvp. Surface SV in file was still slightly out compared to drop keel sensor however the reading was the same at approx 30-40m. File manually edited for top region. |