Please login if you have access to particular applications.
Event details
Voyage: | IN2019_V04 [details] | ||
Subject: | Reconnected foremast barometer to static pressure head | ||
When: | 2019-08-07 13:18:16 UTC - entered into Elog/Everlog as 2019-08-07 13:18:16 | ||
Log: | in2019_v04 | ||
Equipment: | Metstation | ||
Position: |
Latitude: -17.93617 Longitude: 148.1705
- entered into Elog as 17 56.17 S, 148 10.23 E | ||
Action: | Other | ||
| |||
Comments: | The barometer had been reading very erroneously on the previous voyage and up until the start of this one. Opening a vent on the catchpot so that the barometer could read lab pressure showed an instant change to expected pressure. This means that there must have been a blockage at the static pressure head or in the tubing. At time of this event, the tubing was blown our and reconnected as per design and will be monitored. |