Please login if you have access to particular applications.
Event details
Voyage: | IN2019_V02 [details] | ||||
Subject: | start pinging | ||||
When: | 2019-03-23 11:27:23 UTC - entered into Elog/Everlog as 2019-03-23 11:27:23 | ||||
Log: | GSM_in2019_v02 | ||||
Equipment: | EM122
Kongsberg EM122 12kHz multibeam echo sounder [view] | ||||
Position: |
Latitude: -46.903 Longitude: 142.201
- entered into Elog as 46 54.18 S, 142 12.06 E | ||||
Action: | Start | ||||
| |||||
Comments: | Had issues re-starting EM122 after it was stopped all day for mooring recovery initially it would not let me ping the EM122 - SIS interface displayed an error with the PPT and error opening sockets restarted SIS restarted whole computer ran BIST tests - failed TX36, TRU power, RX channels and RX noise levels tests closed SIS restared EM122 transducers by turning of the switch in the rack in ops, waiting 5 - 10 minutes, turning the switch on again all worked fine after re-start :) POSMV logging re-started as in2019_v02_2 |