Deployment Details
Survey: - SS2013_T03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Operation No.: 22
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-08-08 20:39 to 2013-08-08 21:10 UTC
Where:
24° 32.8' S
153° 37.7' E
to
24° 33.1' S
153° 37.9' E
Maximum Depth (m): 501
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1059 | 5.3 | 23.53 | ||||||
1062 | 5.3 | 0.05 | 23.53 | 0.10 | 0.02 | 0.91 | ||
1024 | 5.4 | 23.53 | ||||||
1064 | 5.5 | 23.53 | ||||||
1006 | 5.5 | 23.53 | ||||||
1055 | 24.8 | 0.04 | 23.54 | 0.10 | 0.03 | 0.92 | ||
1063 | 70.3 | < 0.02 | 23.01 | 0.10 | 0.08 | 0.86 | ||
1071 | 80.6 | 22.86 | ||||||
1054 | 81.2 | 22.86 | ||||||
6 | 81.3 | 22.86 | ||||||
1061 | 81.3 | 22.86 | ||||||
1010 | 82 | 0.09 | 22.86 | 0.11 | 0.07 | 0.85 | ||
1050 | 124.9 | 187.26 | 35.512 | 3.73 | 21.32 | 0.35 | < 0.02 | 1.68 |
1001 | 149.9 | 5.45 | 20.41 | 0.45 | < 0.02 | 1.64 | ||
1068 | 200.7 | 7.45 | 18.50 | 0.59 | < 0.02 | 2.43 | ||
1067 | 299.7 | 11.86 | 14.71 | 0.88 | < 0.02 | 4.63 | ||
1053 | 400.6 | 16.30 | 11.49 | 1.15 | < 0.02 | 6.60 | ||
1060 | 501 | 200.01 | 34.712 | 20.02 | 9.54 | 1.38 | < 0.02 | 9.23 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |