Deployment Details
Survey: - SS2013_T03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Operation No.: 21
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-08-07 20:27 to 2013-08-07 20:43 UTC
Where:
20° 58.6' S
152° 30.1' E
to
20° 58.5' S
152° 30.0' E
Maximum Depth (m): 135.4
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1054 | 4.9 | 23.50 | ||||||
1055 | 4.9 | 23.50 | ||||||
1024 | 5 | 23.50 | ||||||
1063 | 5 | 23.50 | ||||||
1071 | 5.1 | 23.50 | ||||||
5 | 5.1 | 23.50 | ||||||
1010 | 5.1 | 23.50 | ||||||
1006 | 5.1 | 23.50 | ||||||
7 | 5.2 | 0.03 | 23.50 | 0.10 | 0.02 | 0.97 | ||
1064 | 5.2 | 23.50 | ||||||
1062 | 5.2 | 23.50 | ||||||
1059 | 5.4 | 23.50 | ||||||
6 | 5.4 | 23.50 | ||||||
1061 | 10.2 | 0.05 | 23.50 | 0.09 | 0.02 | 1.00 | ||
1050 | 24.9 | 0.06 | 23.50 | 0.10 | < 0.02 | 0.97 | ||
1001 | 50.5 | 0.17 | 23.48 | 0.11 | 0.04 | 1.01 | ||
1068 | 75.6 | 1.19 | 23.07 | 0.18 | 0.04 | 1.26 | ||
1067 | 100.6 | 3.94 | 21.58 | 0.35 | < 0.02 | 1.75 | ||
1060 | 135.3 | 18.00 | ||||||
1053 | 135.4 | 169.27 | 35.467 | 8.18 | 18.00 | 0.61 | < 0.02 | 2.93 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |