Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_T03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Operation No.: 20
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-08-06 21:16 to 2013-08-06 21:25 UTC
Where: 
19° 03.8' S   
148° 58.7' E
 to 
19° 03.9' S   
148° 58.7' E
Maximum Depth (m): 57.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|
| 7 | 10.1 | 0.06 | 23.60 | 0.09 | < 0.02 | 0.96 | ||
| 5 | 29.5 | 0.06 | 23.60 | 0.09 | < 0.02 | 0.95 | ||
| 1001 | 29.5 | 23.60 | ||||||
| 1059 | 29.6 | 23.60 | ||||||
| 1061 | 29.6 | 23.60 | ||||||
| 1071 | 29.6 | 23.60 | ||||||
| 1064 | 29.6 | 23.60 | ||||||
| 1067 | 29.6 | 23.60 | ||||||
| 1063 | 29.6 | 23.60 | ||||||
| 1062 | 29.7 | 23.60 | ||||||
| 1024 | 29.7 | 23.60 | ||||||
| 1006 | 29.7 | 23.60 | ||||||
| 1010 | 29.7 | 23.60 | ||||||
| 1055 | 29.8 | 23.60 | ||||||
| 1068 | 29.8 | 23.60 | ||||||
| 1053 | 39.8 | 0.07 | 23.61 | 0.09 | < 0.02 | 0.96 | ||
| 1060 | 57.5 | 209.89 | 35.419 | 0.58 | 23.30 | 0.12 | 0.04 | 1.11 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
| Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
| Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) | 
| Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) | 
| Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) | 
| Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) | 
| Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) | 
| Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |