Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_T03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Operation No.: 5
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-29 07:07 to 2013-07-29 07:19 UTC
Where:
13° 01.6' S
125° 57.2' E
to
13° 01.6' S
125° 57.3' E
Maximum Depth (m): 58.1
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 1062 | 4.7 | 26.97 | ||||||
| 7 | 4.8 | 207.01 | 34.366 | 0.02 | 26.96 | 0.10 | < 0.02 | 2.37 |
| 1006 | 4.8 | 26.96 | ||||||
| 1054 | 4.9 | 26.97 | ||||||
| 1064 | 4.9 | 26.96 | ||||||
| 1061 | 4.9 | 26.97 | ||||||
| 1024 | 5 | 26.96 | ||||||
| 6 | 5.1 | 26.97 | ||||||
| 5 | 5.1 | 26.96 | ||||||
| 1001 | 14.1 | 26.71 | ||||||
| 1071 | 14.2 | 26.71 | ||||||
| 1063 | 14.3 | 26.71 | ||||||
| 1059 | 14.5 | 26.71 | ||||||
| 1010 | 14.6 | 26.72 | ||||||
| 1055 | 14.8 | 26.71 | ||||||
| 1050 | 14.8 | 26.72 | ||||||
| 1068 | 25 | 0.37 | 26.68 | 0.16 | 0.02 | 2.99 | ||
| 1067 | 34.6 | 0.37 | 26.68 | 0.18 | 0.02 | 3.00 | ||
| 1053 | 46.8 | 0.37 | 26.68 | 0.16 | 0.02 | 3.02 | ||
| 1060 | 58.1 | 0.37 | 26.68 | 0.17 | 0.02 | 3.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
| Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
| Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
| Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
| Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
| Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
| Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |