Please login if you have access to particular applications.
Deployment Details
Survey: - SS2011_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 38
Operation No.: 38
Gear: CTD 21,Conductivity CTD 21-SN 3169,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2011-09-12 01:51 to 2011-09-12 02:14 UTC
Where:
32° 25.3' S
113° 38.4' E
to
32° 25.3' S
113° 38.6' E
Maximum Depth (m): 1005.2
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
18 | 5.1 | < 0.02 | 17.35 | 0.20 | 0.02 | 1.71 | ||
16 | 24.8 | < 0.02 | 17.17 | 0.05 | 0.04 | 1.74 | ||
14 | 46.8 | < 0.02 | 16.99 | 0.05 | 0.04 | 1.68 | ||
11 | 85 | 0.41 | 16.80 | 0.07 | 0.04 | 1.69 | ||
9 | 101.3 | 227.85 | 35.652 | 0.87 | 16.60 | 0.12 | 0.03 | 1.68 |
8 | 150.4 | 2.78 | 15.15 | 0.30 | 0.04 | 1.37 | ||
7 | 200.4 | 5.39 | 12.99 | 0.49 | 0.03 | 1.22 | ||
6 | 250.8 | 7.87 | 12.11 | 0.65 | 0.03 | 1.57 | ||
5 | 301.4 | 11.09 | 10.83 | 0.82 | 0.04 | 2.25 | ||
4 | 400.8 | 14.71 | 9.71 | 1.05 | 0.04 | 3.79 | ||
3 | 500.6 | 17.10 | 9.23 | 1.20 | 0.04 | 4.77 | ||
2 | 750.9 | 26.78 | 6.72 | 1.81 | 0.03 | 17.71 | ||
1 | 1005.2 | 186.77 | 33.58 | 3.97 | 2.29 | 0.04 | 48.13 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 3169 | Seabird | SBE4C | 3169 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |