Please login if you have access to particular applications.
Deployment Details
Survey: - SS2011_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 32
Operation No.: 32
Gear: CTD 21,Conductivity CTD 21-SN 3169,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2011-09-11 05:43 to 2011-09-11 05:52 UTC
Where:
32° 35.5' S
114° 16.5' E
to
32° 35.6' S
114° 16.6' E
Maximum Depth (m): 501.3
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
10 | 3.7 | < 0.02 | 17.33 | 0.06 | 0.02 | 1.70 | ||
9 | 24.1 | < 0.02 | 16.84 | 0.07 | 0.02 | 1.69 | ||
8 | 50 | < 0.02 | 16.76 | 0.07 | 0.02 | 1.67 | ||
7 | 73.3 | < 0.02 | 16.66 | 0.08 | 0.04 | 1.67 | ||
6 | 98.5 | 241.88 | 35.605 | 0.68 | 16.48 | 0.13 | 0.02 | 1.60 |
5 | 151.5 | 2.57 | 14.86 | 0.30 | 0.04 | 1.29 | ||
4 | 201.6 | 5.41 | 13.30 | 0.50 | < 0.02 | 1.20 | ||
3 | 300.9 | 12.62 | 10.59 | 0.93 | 0.02 | 2.76 | ||
2 | 400.3 | 17.31 | 9.28 | 1.20 | 0.02 | 4.67 | ||
1 | 501.3 | 243.40 | 34.601 | 19.57 | 8.72 | 1.34 | < 0.02 | 6.24 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 3169 | Seabird | SBE4C | 3169 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |