Please login if you have access to particular applications.
Deployment Details
Survey: - SS2010_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 160
Operation No.: 1
Gear: Altitude CTD 21-41023,CTD 21,Conductivity CTD 21-SN 2312,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Nitrate - CTD21 Satlantic ISUS V3-076,Oxygen-CTD 21-SBE 43-SN 1239,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2010-05-01 17:20 to 2010-05-01 17:32 UTC
Where:
16° 39.9' S
120° 51.1' E
to
16° 39.9' S
120° 51.1' E
Maximum Depth (m): 188
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
| Bottle Number |
Pressure |
Nitrate (µM) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|
| 1053 | 2.3 | < 0.02 | 0.03 | 0.11 | < 0.02 | 2.89 |
| 1066 | 28.8 | < 0.02 | 0.02 | 0.10 | < 0.02 | 2.84 |
| 1062 | 53.3 | 0.03 | 0.10 | 0.09 | < 0.02 | 3.47 |
| 1067 | 67.2 | 1.56 | 0.23 | 0.15 | 0.30 | 5.44 |
| 1057 | 101.7 | 6.06 | 0.49 | 0.11 | 0.09 | 8.85 |
| 1024 | 149.9 | 12.76 | 0.89 | 0.11 | < 0.02 | 15.22 |
| 1068 | 188.1 | 19.54 | 1.33 | 0.11 | < 0.02 | 27.13 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Altitude CTD 21-41023 | PSA | 916T | 41023 | Altitude(m) |
| CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
| Conductivity CTD 21-SN 2312 | Seabird | SBE-4 | 2312 | |
| Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
| Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Nitrate - CTD21 Satlantic ISUS V3-076 | Satlantic | V3 | 076 | Nitrate (µM) |
| Oxygen-CTD 21-SBE 43-SN 1239 | Seabird | SBE 43 | 1239 | Oxygen (µM) |
| Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
| Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
| Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |