Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 40
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-11-10 17:08 to 2025-11-10 17:41 UTC
Where: 21° 40.1' S 153° 30.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 23 | 1.5 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 1.6 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 1.6 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 1.7 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 1.7 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 1.9 | 205.66 | 35.159 | 0.05 | 27.90 | 0.06 | < 0.02 | 0.02 | 0.85 |
| 31 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 2 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 20 | 206.07 | 35.157 | 0.05 | 27.87 | 0.05 | < 0.02 | < 0.02 | 0.88 |
| 19 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 75.6 | 180.25 | 35.573 | 0.64 | 24.92 | 0.22 | < 0.02 | 0.05 | 0.81 |
| 17 | 75.7 | < 0.02 | < 0.02 | < 0.02 | 24.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 200.4 | 163.82 | 35.683 | 6.24 | 20.53 | 0.54 | < 0.02 | 0.03 | 1.40 |
| 15 | 200.4 | < 0.02 | < 0.02 | < 0.02 | 20.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 302 | 172.61 | 35.266 | 11.54 | 15.50 | 0.87 | < 0.02 | 0.02 | 3.96 |
| 13 | 302.1 | < 0.02 | < 0.02 | < 0.02 | 15.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 402 | < 0.02 | < 0.02 | < 0.02 | 11.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 402 | 191.60 | 34.910 | 16.52 | 11.72 | 1.16 | < 0.02 | 0.02 | 6.51 |
| 2 | 477.9 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 478 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 478 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 478.1 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 478.2 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 478.2 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 478.2 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 478.2 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 478.2 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 478.4 | 198.34 | 34.770 | 18.90 | 10.31 | 1.31 | < 0.02 | 0.02 | 8.01 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |