Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 39
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-11-09 06:40 to 2025-11-09 07:03 UTC
Where: 21° 48.7' S 153° 53.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 1.8 | < 0.02 | < 0.02 | < 0.02 | 27.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 1.9 | 207.50 | 35.238 | 0.05 | 27.17 | 0.06 | < 0.02 | 0.02 | 0.81 |
| 33 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 27.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 2 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 2 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 2.1 | < 0.02 | < 0.02 | < 0.02 | 27.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 27.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 19.8 | 207.85 | 35.234 | 0.05 | 27.04 | 0.06 | < 0.02 | < 0.02 | 0.81 |
| 23 | 19.9 | < 0.02 | < 0.02 | < 0.02 | 27.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 104.2 | < 0.02 | < 0.02 | < 0.02 | 23.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 104.2 | 188.29 | 35.569 | 1.84 | 23.69 | 0.26 | 0.06 | 0.24 | 0.88 |
| 19 | 104.2 | < 0.02 | < 0.02 | < 0.02 | 23.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 200.2 | 166.09 | 35.539 | 8.13 | 18.70 | 0.66 | < 0.02 | 0.03 | 2.36 |
| 17 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 18.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 18.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 299.7 | 180.12 | 35.223 | 12.10 | 14.70 | 0.88 | < 0.02 | 0.04 | 4.41 |
| 10 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 299.7 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 299.8 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 299.8 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 299.8 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 299.8 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 299.8 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |