Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 31
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-31 18:16 to 2025-10-31 19:12 UTC
Where: 17° 28.6' S 155° 50.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 33 | 2.3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 3.1 | 202.58 | 34.972 | 0.03 | 28.29 | 0.10 | < 0.02 | 0.02 | 0.78 |
| 35 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 19.5 | 203.07 | 34.992 | 0.04 | 28.20 | 0.09 | < 0.02 | 0.02 | 0.80 |
| 25 | 19.7 | < 0.02 | < 0.02 | < 0.02 | 28.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 76 | < 0.02 | < 0.02 | < 0.02 | 24.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 76 | 194.68 | 35.626 | 0.13 | 24.95 | 0.15 | < 0.02 | 0.02 | 0.67 |
| 21 | 201.4 | < 0.02 | < 0.02 | < 0.02 | 20.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 201.4 | 163.73 | 35.685 | 6.22 | 20.35 | 0.56 | < 0.02 | 0.02 | 1.57 |
| 19 | 300.4 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 300.4 | 170.11 | 35.338 | 9.66 | 16.73 | 0.79 | < 0.02 | 0.02 | 3.25 |
| 18 | 399.2 | 183.07 | 35.085 | 13.19 | 13.80 | 0.98 | < 0.02 | 0.02 | 5.02 |
| 17 | 399.3 | < 0.02 | < 0.02 | < 0.02 | 13.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 10.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 500.7 | 193.43 | 34.720 | 19.36 | 10.41 | 1.38 | < 0.02 | 0.02 | 9.28 |
| 13 | 750.1 | < 0.02 | < 0.02 | < 0.02 | 5.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 750.1 | 189.85 | 34.403 | 30.11 | 5.66 | 2.08 | < 0.02 | 0.02 | 31.09 |
| 12 | 1000.6 | 172.79 | 34.461 | 33.43 | 4.32 | 2.33 | < 0.02 | 0.02 | 58.65 |
| 11 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 4.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1097.2 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1097.2 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1097.3 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1097.3 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1097.3 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 1097.3 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1097.3 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1097.4 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1097.4 | < 0.02 | < 0.02 | < 0.02 | 3.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 1097.4 | 164.98 | 34.510 | 34.52 | 3.69 | 2.42 | < 0.02 | 0.02 | 74.97 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |