Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 29
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-31 02:44 to 2025-10-31 04:46 UTC
Where: 17° 20.7' S 155° 43.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 28.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 28.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 2.7 | 203.88 | 35.165 | 0.03 | 28.25 | 0.10 | < 0.02 | 0.02 | 0.70 |
| 36 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 28.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 28.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 28.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 20.1 | 206.65 | 35.220 | 0.03 | 27.51 | 0.09 | < 0.02 | 0.02 | 0.64 |
| 30 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 27.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 105.2 | 192.94 | 35.647 | 0.48 | 24.02 | 0.17 | < 0.02 | 0.08 | 0.62 |
| 28 | 105.2 | < 0.02 | < 0.02 | < 0.02 | 24.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 20.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 200.4 | 173.06 | 35.666 | 5.02 | 20.86 | 0.44 | < 0.02 | 0.03 | 1.20 |
| 24 | 300.6 | < 0.02 | < 0.02 | < 0.02 | 17.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 300.8 | 177.04 | 35.418 | 8.57 | 17.06 | 0.67 | < 0.02 | 0.02 | 2.57 |
| 22 | 400.3 | < 0.02 | < 0.02 | < 0.02 | 12.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 400.4 | 181.37 | 34.957 | 15.10 | 12.81 | 1.11 | < 0.02 | 0.02 | 6.29 |
| 19 | 500.1 | 194.14 | 34.657 | 20.61 | 9.77 | 1.45 | < 0.02 | 0.02 | 10.15 |
| 20 | 500.2 | < 0.02 | < 0.02 | < 0.02 | 9.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 750.2 | 188.38 | 34.407 | 30.36 | 5.67 | 2.09 | < 0.02 | 0.02 | 31.91 |
| 18 | 750.4 | < 0.02 | < 0.02 | < 0.02 | 5.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1000.5 | < 0.02 | < 0.02 | < 0.02 | 4.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1000.5 | 173.64 | 34.455 | 33.38 | 4.38 | 2.32 | < 0.02 | 0.02 | 56.40 |
| 13 | 1500.1 | 153.28 | 34.584 | 36.00 | 2.94 | 2.53 | < 0.02 | 0.02 | 98.81 |
| 14 | 1500.3 | < 0.02 | < 0.02 | < 0.02 | 2.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2000.1 | 155.02 | 34.644 | 36.06 | 2.35 | 2.55 | < 0.02 | 0.02 | 111.88 |
| 12 | 2000.2 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2145.2 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 2145.3 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 2145.4 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 2145.4 | 159.17 | 34.665 | 35.70 | 2.22 | 2.52 | < 0.02 | 0.02 | 112.10 |
| 10 | 2145.4 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2145.4 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 2145.4 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2145.5 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 2145.5 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 2145.5 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |