Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-29 02:34 to 2025-10-29 03:16 UTC
Where: 18° 21.7' S 155° 22.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 28 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 27.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 27.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 27.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 3.4 | 205.22 | 35.150 | 0.05 | 27.70 | 0.09 | < 0.02 | 0.02 | 0.56 |
| 25 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 27.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 27.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 27.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 20 | < 0.02 | < 0.02 | < 0.02 | 26.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 20.2 | 211.02 | 35.324 | 0.07 | 26.51 | 0.06 | < 0.02 | < 0.02 | 0.44 |
| 20 | 134.4 | 206.83 | 35.572 | 0.05 | 23.63 | 0.12 | < 0.02 | 0.04 | 0.43 |
| 19 | 134.4 | < 0.02 | < 0.02 | < 0.02 | 23.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 200.1 | 176.90 | 35.685 | 3.94 | 21.80 | 0.37 | < 0.02 | 0.03 | 0.79 |
| 17 | 200.1 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 300.3 | < 0.02 | < 0.02 | < 0.02 | 18.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 300.3 | 174.09 | 35.493 | 7.62 | 18.04 | 0.61 | < 0.02 | 0.02 | 1.94 |
| 13 | 400.3 | < 0.02 | < 0.02 | < 0.02 | 15.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 400.3 | 176.81 | 35.180 | 11.67 | 15.05 | 0.88 | < 0.02 | 0.02 | 3.95 |
| 11 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 10.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 500.2 | 190.03 | 34.710 | 19.56 | 10.51 | 1.38 | < 0.02 | < 0.02 | 9.27 |
| 3 | 705.3 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 705.3 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 705.4 | 194.90 | 34.454 | 28.22 | 6.37 | 1.93 | < 0.02 | < 0.02 | 24.06 |
| 9 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 705.5 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |