Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-25 08:16 to 2025-10-25 09:35 UTC
Where: 21° 28.1' S 156° 37.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3.3 | 212.14 | 35.402 | 0.02 | 25.52 | 0.06 | < 0.02 | < 0.02 | 0.60 |
| 30 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 25.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 25.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 25.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 25.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 25.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 25.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 25.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 20.2 | 213.30 | 35.381 | 0.02 | 25.25 | 0.06 | < 0.02 | 0.02 | 0.63 |
| 26 | 105.2 | 195.66 | 35.628 | 0.85 | 23.73 | 0.19 | 0.02 | 0.10 | 0.62 |
| 25 | 105.3 | < 0.02 | < 0.02 | < 0.02 | 23.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 20.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 200.4 | 179.67 | 35.651 | 4.32 | 20.90 | 0.39 | < 0.02 | 0.03 | 0.96 |
| 22 | 300.5 | 183.07 | 35.490 | 7.55 | 17.37 | 0.58 | < 0.02 | 0.03 | 1.95 |
| 21 | 300.6 | < 0.02 | < 0.02 | < 0.02 | 17.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 400 | < 0.02 | < 0.02 | < 0.02 | 15.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 400.1 | 185.75 | 35.335 | 9.83 | 15.61 | 0.72 | < 0.02 | 0.02 | 2.86 |
| 17 | 500 | < 0.02 | < 0.02 | < 0.02 | 11.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 500.1 | 196.06 | 34.870 | 16.99 | 11.32 | 1.18 | < 0.02 | 0.02 | 6.41 |
| 16 | 750.3 | 206.74 | 34.425 | 27.16 | 6.45 | 1.85 | < 0.02 | 0.02 | 21.11 |
| 15 | 750.4 | < 0.02 | < 0.02 | < 0.02 | 6.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 999.8 | 179.72 | 34.466 | 32.52 | 4.51 | 2.24 | < 0.02 | 0.02 | 54.61 |
| 13 | 999.9 | < 0.02 | < 0.02 | < 0.02 | 4.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1570.2 | < 0.02 | < 0.02 | < 0.02 | 2.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1570.3 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1570.3 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1570.3 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1570.4 | 152.65 | 34.591 | 36.06 | 2.90 | 2.53 | < 0.02 | < 0.02 | 99.12 |
| 10 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1570.4 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1570.5 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |