Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-17 09:54 to 2025-10-17 11:26 UTC
Where: 23° 49.5' S 154° 19.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 4 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.8 | 212.23 | 35.342 | 0.02 | 25.45 | 0.06 | < 0.02 | < 0.02 | 0.93 |
| 28 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 20.4 | 212.45 | 35.343 | 0.02 | 25.45 | 0.06 | < 0.02 | 0.02 | 0.93 |
| 26 | 85.3 | < 0.02 | < 0.02 | < 0.02 | 23.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 85.3 | 219.42 | 35.525 | 0.05 | 23.08 | 0.10 | < 0.02 | 0.02 | 0.85 |
| 24 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 19.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 200.3 | 166.81 | 35.594 | 7.11 | 19.37 | 0.59 | < 0.02 | 0.03 | 2.04 |
| 22 | 300 | < 0.02 | < 0.02 | < 0.02 | 16.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 300 | 179.45 | 35.349 | 9.87 | 16.09 | 0.74 | < 0.02 | 0.02 | 3.31 |
| 19 | 400.3 | 189.94 | 35.075 | 14.03 | 13.10 | 1.00 | < 0.02 | 0.02 | 5.20 |
| 20 | 400.4 | < 0.02 | < 0.02 | < 0.02 | 13.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 9.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 500.8 | 201.20 | 34.713 | 19.92 | 9.75 | 1.37 | < 0.02 | < 0.02 | 8.84 |
| 15 | 750.7 | 205.66 | 34.444 | 26.72 | 6.64 | 1.83 | < 0.02 | 0.02 | 20.73 |
| 16 | 750.8 | < 0.02 | < 0.02 | < 0.02 | 6.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1000.8 | 185.25 | 34.456 | 31.59 | 4.82 | 2.18 | < 0.02 | < 0.02 | 47.71 |
| 14 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 4.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1500.6 | 154.04 | 34.574 | 35.63 | 3.13 | 2.50 | < 0.02 | < 0.02 | 93.29 |
| 12 | 1500.8 | < 0.02 | < 0.02 | < 0.02 | 3.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1889.2 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1889.4 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1889.4 | 166.00 | 34.659 | 34.76 | 2.35 | 2.43 | < 0.02 | 0.02 | 100.53 |
| 2 | 1889.5 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1889.5 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1889.6 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 1889.6 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1889.8 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 1889.8 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1889.8 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |