Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6024,Transmissometer - CTD 24 -CST-1735DR
When: 2025-10-15 20:59 to 2025-10-15 22:50 UTC
Where: 23° 13.9' S 155° 10.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 25.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.1 | 212.77 | 35.359 | 0.02 | 25.02 | 0.08 | < 0.02 | < 0.02 | 0.79 |
| 36 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 19.7 | 212.68 | 35.359 | 0.02 | 25.01 | 0.08 | < 0.02 | < 0.02 | 0.81 |
| 30 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 25.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 100.6 | 178.51 | 35.689 | 2.37 | 23.66 | 0.31 | < 0.02 | 0.13 | 0.91 |
| 28 | 100.7 | < 0.02 | < 0.02 | < 0.02 | 23.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 199.7 | 161.94 | 35.696 | 6.58 | 20.57 | 0.57 | < 0.02 | 0.03 | 1.65 |
| 26 | 199.8 | < 0.02 | < 0.02 | < 0.02 | 20.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 299.6 | < 0.02 | < 0.02 | < 0.02 | 17.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 299.7 | 182.93 | 35.478 | 7.58 | 17.39 | 0.59 | < 0.02 | 0.02 | 2.14 |
| 21 | 401.4 | 187.22 | 35.170 | 12.31 | 14.10 | 0.89 | < 0.02 | 0.02 | 4.13 |
| 22 | 401.4 | < 0.02 | < 0.02 | < 0.02 | 14.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 500.3 | 197.54 | 34.856 | 17.27 | 11.10 | 1.20 | < 0.02 | 0.02 | 6.61 |
| 20 | 500.3 | < 0.02 | < 0.02 | < 0.02 | 11.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 749.7 | < 0.02 | < 0.02 | < 0.02 | 6.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 749.7 | 207.72 | 34.440 | 26.35 | 6.74 | 1.80 | < 0.02 | 0.02 | 18.79 |
| 15 | 1000.3 | 182.53 | 34.455 | 32.05 | 4.67 | 2.21 | < 0.02 | < 0.02 | 50.72 |
| 16 | 1000.4 | < 0.02 | < 0.02 | < 0.02 | 4.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1500.2 | 151.36 | 34.571 | 35.92 | 3.14 | 2.52 | < 0.02 | < 0.02 | 94.56 |
| 14 | 1500.4 | < 0.02 | < 0.02 | < 0.02 | 3.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1999.4 | < 0.02 | < 0.02 | < 0.02 | 2.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1999.6 | 153.14 | 34.636 | 36.01 | 2.45 | 2.53 | < 0.02 | 0.02 | 109.12 |
| 6 | 2637.3 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 2637.3 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 2637.4 | 176.59 | 34.692 | 33.94 | 2.07 | 2.36 | < 0.02 | < 0.02 | 101.94 |
| 9 | 2637.4 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2637.4 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 2637.5 | < 0.02 | < 0.02 | < 0.02 | 2.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 2637.5 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2637.5 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 2637.5 | < 0.02 | < 0.02 | < 0.02 | 2.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2637.6 | < 0.02 | < 0.02 | < 0.02 | 2.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |