Deployment Details
Survey: - IN2022_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Optode Dissolved Oxygen Concentration,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4718,Transmissometer,VMP Microstructure profiler
When: 2022-07-27 02:42 to 2022-07-27 04:46 UTC
Where: 27° 05.9' S 154° 24.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 10.2 | 224.47 | 35.587 | 0.37 | 20.70 | 0.11 | < 0.02 | 0.06 | 0.58 |
26 | 20.5 | 224.42 | 35.586 | 0.36 | 20.70 | 0.11 | < 0.02 | 0.06 | 0.67 |
25 | 40.4 | 224.15 | 35.585 | 0.37 | 20.70 | 0.11 | < 0.02 | 0.06 | 0.66 |
24 | 70.4 | 219.46 | 35.599 | 0.72 | 20.70 | 0.13 | < 0.02 | 0.06 | 0.64 |
23 | 89.7 | 201.69 | 35.653 | 2.29 | 20.51 | 0.23 | < 0.02 | 0.04 | 0.78 |
22 | 124.8 | 206.24 | 35.650 | 2.62 | 19.77 | 0.26 | < 0.02 | 0.13 | 0.87 |
21 | 180.4 | 187.40 | 35.651 | 5.21 | 19.00 | 0.43 | < 0.02 | < 0.02 | 1.40 |
20 | 200.1 | 200.44 | 35.673 | 3.99 | 18.88 | 0.34 | < 0.02 | < 0.02 | 0.98 |
19 | 289.7 | 189.85 | 35.524 | 7.09 | 17.18 | 0.54 | < 0.02 | < 0.02 | 1.92 |
12 | 409.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 410.1 | < 0.02 | < 0.02 | < 0.02 | 14.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 410.1 | < 0.02 | < 0.02 | < 0.02 | 14.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 410.2 | 193.25 | 35.228 | 11.36 | 14.07 | 0.82 | < 0.02 | < 0.02 | 3.49 |
18 | 410.3 | < 0.02 | < 0.02 | < 0.02 | 14.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 410.3 | < 0.02 | < 0.02 | < 0.02 | 14.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 410.5 | < 0.02 | < 0.02 | < 0.02 | 14.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 410.5 | < 0.02 | < 0.02 | < 0.02 | 14.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 710.2 | 210.44 | 34.507 | 23.94 | 7.66 | 1.62 | < 0.02 | < 0.02 | 13.25 |
8 | 911.1 | 199.41 | 34.432 | 28.64 | 5.92 | 1.95 | < 0.02 | < 0.02 | 28.24 |
7 | 1101.3 | < 0.02 | < 0.02 | < 0.02 | 4.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1101.5 | 182.66 | 34.455 | 31.89 | 4.70 | 2.19 | < 0.02 | < 0.02 | 49.75 |
4 | 1400.8 | 162.34 | 34.533 | 34.64 | 3.60 | 2.41 | < 0.02 | < 0.02 | 78.44 |
3 | 1598 | 155.20 | 34.588 | 35.55 | 2.97 | 2.49 | < 0.02 | < 0.02 | 93.74 |
2 | 1799.4 | 160.38 | 34.628 | 35.19 | 2.60 | 2.47 | < 0.02 | < 0.02 | 96.82 |
1 | 2002.2 | 169.35 | 34.663 | 34.33 | 2.35 | 2.40 | < 0.02 | < 0.02 | 94.93 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24 - SN 4718 | Sea-Bird Electronics Inc | SBE3T | 4718 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |