Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 16
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Optode Dissolved Oxygen Concentration,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4718,Transmissometer,VMP Microstructure profiler
When: 2022-07-20 08:10 to 2022-07-20 10:24 UTC
Where: 27° 19.5' S 154° 03.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Temperature (deg C) |
|---|---|---|---|---|
| 27 | 20.3 | 222.19 | 35.484 | 21.66 |
| 26 | 40.7 | 221.88 | 35.501 | 21.60 |
| 25 | 90.5 | 221.16 | 35.583 | 21.00 |
| 24 | 120.6 | 220.89 | 35.609 | 20.82 |
| 23 | 150.8 | 201.78 | 35.658 | 20.55 |
| 22 | 189.6 | 194.23 | 35.678 | 19.50 |
| 21 | 335.3 | 179.45 | 35.337 | 15.76 |
| 20 | 450.6 | 199.68 | 35.120 | 12.88 |
| 19 | 550.2 | 201.96 | 34.726 | 9.93 |
| 15 | 699.9 | < 0.02 | < 0.02 | 7.66 |
| 13 | 700.2 | < 0.02 | < 0.02 | 7.66 |
| 18 | 700.2 | < 0.02 | < 0.02 | 7.66 |
| 12 | 700.2 | < 0.02 | < 0.02 | 7.66 |
| 16 | 700.3 | < 0.02 | < 0.02 | 7.66 |
| 10 | 700.3 | 209.33 | 34.506 | 7.66 |
| 17 | 700.4 | < 0.02 | < 0.02 | 7.66 |
| 14 | 700.5 | < 0.02 | < 0.02 | 7.66 |
| 9 | 900.7 | 199.63 | 34.429 | 5.90 |
| 8 | 1050.7 | 188.34 | 34.442 | 5.11 |
| 7 | 1201.5 | 175.34 | 34.481 | 4.32 |
| 6 | 1370.8 | 162.88 | 34.526 | 3.67 |
| 4 | 1550.8 | 155.69 | 34.590 | 2.94 |
| 3 | 1680.2 | 159.44 | 34.625 | 2.64 |
| 2 | 1801.4 | 165.07 | 34.648 | 2.45 |
| 1 | 2001.6 | 174.49 | 34.683 | 2.22 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24 - SN 4718 | Sea-Bird Electronics Inc | SBE3T | 4718 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) | ||
| VMP Microstructure profiler | Temperature (deg C) |