Deployment Details
Survey: - IN2022_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Optode Dissolved Oxygen Concentration,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4718,Transmissometer,VMP Microstructure profiler
When: 2022-07-18 06:17 to 2022-07-18 09:22 UTC
Where: 27° 17.4' S 154° 09.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 4.7 | 220.58 | 35.451 | 0.17 | 21.92 | 0.10 | 0.02 | 0.02 | 0.83 |
26 | 30.4 | 217.95 | 35.520 | 0.38 | 21.66 | 0.10 | 0.03 | 0.05 | 0.82 |
25 | 50.6 | 212.72 | 35.570 | 0.70 | 21.57 | 0.12 | < 0.02 | 0.13 | 0.83 |
24 | 80.6 | 200.59 | 35.610 | 0.98 | 21.43 | 0.14 | < 0.02 | 0.12 | 0.87 |
23 | 100.4 | 200.22 | 35.658 | 1.69 | 21.31 | 0.20 | < 0.02 | 0.07 | 1.02 |
22 | 110 | 192.13 | 35.670 | 2.67 | 21.00 | 0.27 | < 0.02 | 0.04 | 1.10 |
21 | 130.6 | 188.96 | 35.684 | 3.32 | 20.55 | 0.30 | < 0.02 | 0.02 | 1.14 |
20 | 220.8 | 190.35 | 35.649 | 5.06 | 18.88 | 0.42 | < 0.02 | < 0.02 | 1.47 |
18 | 390.2 | < 0.02 | < 0.02 | < 0.02 | 13.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 390.3 | < 0.02 | < 0.02 | < 0.02 | 13.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 390.3 | < 0.02 | < 0.02 | < 0.02 | 13.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 390.4 | 191.06 | 35.189 | 11.70 | 14.03 | 0.85 | < 0.02 | < 0.02 | 3.88 |
15 | 390.8 | < 0.02 | < 0.02 | < 0.02 | 14.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 392.4 | < 0.02 | < 0.02 | < 0.02 | 14.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 394.2 | < 0.02 | < 0.02 | < 0.02 | 14.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 395.6 | < 0.02 | < 0.02 | < 0.02 | 14.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 451.1 | 196.91 | 35.110 | 13.15 | 13.00 | 0.95 | < 0.02 | < 0.02 | 4.52 |
9 | 708.3 | 209.64 | 34.508 | 23.82 | 7.72 | 1.63 | < 0.02 | < 0.02 | 13.52 |
8 | 900.3 | 201.38 | 34.428 | 28.39 | 5.98 | 1.94 | < 0.02 | < 0.02 | 27.39 |
7 | 1198.9 | 173.91 | 34.487 | 33.05 | 4.25 | 2.28 | < 0.02 | < 0.02 | 61.14 |
6 | 1598.1 | 155.51 | 34.600 | 35.62 | 2.85 | 2.50 | < 0.02 | < 0.02 | 96.63 |
4 | 2101.2 | 177.21 | 34.690 | 33.77 | 2.16 | 2.34 | < 0.02 | < 0.02 | 96.61 |
3 | 2599.5 | 190.70 | 34.723 | 32.94 | 1.73 | 2.29 | < 0.02 | < 0.02 | 104.40 |
2 | 3000.2 | 194.19 | 34.724 | 32.95 | 1.54 | 2.29 | < 0.02 | < 0.02 | 109.46 |
1 | 3262.7 | 197.94 | 34.720 | 33.17 | 1.30 | 2.31 | < 0.02 | < 0.02 | 115.27 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24 - SN 4718 | Sea-Bird Electronics Inc | SBE3T | 4718 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |