Deployment Details
Survey: - IN2022_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Optode Dissolved Oxygen Concentration,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4718,Transmissometer,VMP Microstructure profiler
When: 2022-07-17 21:41 to 2022-07-18 00:47 UTC
Where: 27° 14.9' S 154° 15.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 6.5 | 221.16 | 35.551 | 0.26 | 21.36 | 0.10 | 0.02 | 0.04 | 0.67 |
26 | 19.8 | 221.21 | 35.551 | 0.25 | 21.34 | 0.10 | < 0.02 | 0.04 | 0.65 |
25 | 39.9 | 219.11 | 35.575 | 0.44 | 21.21 | 0.11 | 0.05 | 0.12 | 0.46 |
24 | 101.7 | 221.07 | 35.589 | 0.36 | 20.94 | 0.10 | 0.03 | 0.18 | 0.46 |
23 | 171.6 | 190.66 | 35.685 | 3.96 | 19.82 | 0.34 | < 0.02 | < 0.02 | 1.03 |
22 | 240.1 | 196.82 | 35.650 | 4.74 | 18.62 | 0.39 | < 0.02 | < 0.02 | 1.28 |
21 | 309.3 | 190.03 | 35.515 | 7.22 | 17.00 | 0.56 | < 0.02 | < 0.02 | 2.03 |
20 | 449.6 | 195.21 | 35.061 | 13.59 | 12.89 | 0.97 | < 0.02 | < 0.02 | 4.54 |
19 | 600.1 | 205.08 | 34.677 | 20.17 | 9.47 | 1.38 | < 0.02 | < 0.02 | 8.53 |
18 | 730.5 | < 0.02 | < 0.02 | < 0.02 | 7.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 730.5 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 730.6 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 730.6 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 730.6 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 730.6 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 730.6 | < 0.02 | < 0.02 | < 0.02 | 7.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 730.6 | 210.00 | 34.479 | 24.81 | 7.33 | 1.68 | < 0.02 | < 0.02 | 15.01 |
9 | 909.5 | 199.14 | 34.428 | 28.79 | 5.89 | 1.96 | < 0.02 | < 0.02 | 28.69 |
8 | 999.9 | 191.28 | 34.434 | 30.44 | 5.26 | 2.09 | < 0.02 | < 0.02 | 38.38 |
7 | 1601.1 | 154.80 | 34.590 | 35.65 | 2.95 | 2.51 | < 0.02 | < 0.02 | 95.12 |
6 | 2038.3 | 171.19 | 34.675 | 34.26 | 2.25 | 2.40 | < 0.02 | < 0.02 | 98.40 |
4 | 2401.8 | 184.85 | 34.713 | 33.11 | 1.96 | 2.31 | < 0.02 | < 0.02 | 98.81 |
3 | 3002.2 | 197.27 | 34.720 | 33.11 | 1.37 | 2.31 | < 0.02 | < 0.02 | 113.33 |
2 | 3498.3 | 199.55 | 34.717 | 33.32 | 1.23 | 2.32 | < 0.02 | < 0.02 | 117.88 |
1 | 4171.8 | 196.37 | 34.716 | 33.42 | 1.21 | 2.33 | < 0.02 | < 0.02 | 120.27 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24 - SN 4718 | Sea-Bird Electronics Inc | SBE3T | 4718 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |