Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Optode Dissolved Oxygen Concentration,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4718,Transmissometer,VMP Microstructure profiler
When: 2022-07-14 22:45 to 2022-07-14 23:26 UTC
Where: 27° 06.6' S 155° 13.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number | Pressure | Oxygen (µM) | Salinity (psu) | Nitrate (µM) | Temperature (deg C) | Orthophosphate (µM) | Ammonia (µM) | Nitrite (µM) | Silicate (µM) | 
|---|---|---|---|---|---|---|---|---|---|
| 12 | 998.6 | 197.49 | 34.431 | 29.40 | 5.74 | 2.01 | < 0.02 | < 0.02 | 31.05 | 
| 9 | 998.9 | 197.04 | 34.432 | 29.43 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.05 | 
| 6 | 998.9 | 196.96 | 34.431 | 29.35 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.08 | 
| 16 | 998.9 | 197.18 | 34.431 | 29.35 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.09 | 
| 3 | 999 | 197.22 | 34.431 | 29.36 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.09 | 
| 2 | 999.1 | 197.27 | 34.431 | 29.38 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.00 | 
| 19 | 999.1 | 197.36 | 34.432 | 29.40 | 5.74 | 2.01 | < 0.02 | < 0.02 | 31.08 | 
| 7 | 999.2 | 197.09 | 34.431 | 29.38 | 5.74 | 2.01 | < 0.02 | < 0.02 | 31.07 | 
| 13 | 999.2 | 197.13 | 34.431 | 29.39 | 5.73 | 2.02 | < 0.02 | < 0.02 | 31.07 | 
| 15 | 999.2 | 197.09 | 34.431 | 29.34 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.03 | 
| 8 | 999.2 | 197.22 | 34.431 | 29.42 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.03 | 
| 17 | 999.2 | 197.22 | 34.431 | 29.38 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.14 | 
| 20 | 999.3 | 197.36 | 34.432 | 29.38 | 5.74 | 2.01 | < 0.02 | < 0.02 | 31.10 | 
| 14 | 999.3 | 197.40 | 34.431 | 29.35 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.03 | 
| 18 | 999.3 | 197.40 | 34.432 | 29.38 | 5.74 | 2.01 | < 0.02 | < 0.02 | 31.12 | 
| 10 | 999.3 | 197.04 | 34.431 | 29.40 | 5.73 | 2.02 | < 0.02 | < 0.02 | 30.99 | 
| 4 | 999.4 | 196.87 | 34.431 | 29.38 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.12 | 
| 33 | 999.5 | 197.27 | 34.432 | 29.33 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.04 | 
| 21 | 999.5 | 197.31 | 34.431 | 29.37 | 5.73 | 2.02 | < 0.02 | < 0.02 | 31.13 | 
| 1 | 999.6 | 197.49 | 34.430 | 29.36 | 5.73 | 2.01 | < 0.02 | < 0.02 | 30.89 | 
| 25 | 999.6 | 238.40 | 34.431 | 29.32 | 5.73 | 2.01 | < 0.02 | < 0.02 | 30.93 | 
| 24 | 999.6 | 197.31 | 34.431 | 29.30 | 5.73 | 2.02 | < 0.02 | < 0.02 | 30.99 | 
| 22 | 999.6 | 197.09 | 34.431 | 29.37 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.11 | 
| 23 | 999.7 | 197.49 | 34.432 | 29.32 | 5.74 | 2.02 | < 0.02 | < 0.02 | 31.09 | 
| 28 | 999.8 | 197.27 | 34.432 | 29.33 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.04 | 
| 29 | 999.8 | 197.13 | 34.432 | 29.33 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.04 | 
| 32 | 999.9 | 197.45 | 34.431 | 29.30 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.05 | 
| 27 | 999.9 | 197.27 | 34.431 | 29.35 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.04 | 
| 26 | 1000 | 197.09 | 34.432 | 29.30 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.03 | 
| 30 | 1000.1 | 197.40 | 34.432 | 29.33 | 5.73 | 2.02 | < 0.02 | < 0.02 | 31.10 | 
| 31 | 1000.3 | 197.71 | 34.431 | 29.33 | 5.73 | 2.02 | < 0.02 | < 0.02 | 31.07 | 
| 34 | 1000.4 | 197.36 | 34.431 | 29.36 | 5.73 | 2.01 | < 0.02 | < 0.02 | 31.02 | 
| 35 | 1000.4 | 197.18 | 34.431 | 29.33 | 5.73 | 2.01 | < 0.02 | < 0.02 | 30.98 | 
| 36 | 1000.6 | 197.18 | 34.432 | 29.37 | 5.73 | 2.01 | < 0.02 | < 0.02 | 30.98 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) | 
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM | 
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) | 
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) | 
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) | 
| Temperature CTD 24 - SN 4718 | Sea-Bird Electronics Inc | SBE3T | 4718 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) | ||
| VMP Microstructure profiler | Temperature (deg C) |