Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 69
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-09 14:15 to 2018-11-09 17:05 UTC
Where: 57° 07.7' S 156° 06.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 11 | < 0.02 | < 0.02 | < 0.02 | 1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 11.3 | 345.94 | 33.797 | 28.09 | 1.52 | 1.98 | 0.31 | 0.22 | 20.04 |
| 34 | 25.4 | 345.77 | 33.797 | 28.00 | 1.52 | 1.98 | 0.31 | 0.21 | 20.00 |
| 33 | 25.5 | < 0.02 | < 0.02 | < 0.02 | 1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 49.9 | 346.21 | 33.799 | 28.02 | 1.51 | 1.98 | 0.32 | 0.21 | 20.28 |
| 31 | 75.3 | 348.40 | 33.819 | 28.43 | 1.24 | 2.02 | 0.33 | 0.20 | 22.89 |
| 30 | 75.3 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 95.1 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 95.2 | < 0.02 | < 0.02 | 29.10 | 0.44 | 2.07 | 0.34 | 0.18 | 27.02 |
| 27 | 110.2 | 346.75 | 33.894 | 29.80 | 0.12 | 2.12 | 0.38 | 0.18 | 32.04 |
| 25 | 140.7 | < 0.02 | < 0.02 | < 0.02 | 0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 140.7 | 322.36 | 33.964 | 30.94 | 0.23 | 2.19 | 0.29 | 0.14 | 36.40 |
| 24 | 170.7 | 226.61 | 34.267 | 34.95 | 1.66 | 2.45 | < 0.02 | 0.03 | 54.30 |
| 23 | 230.4 | 198.21 | 34.387 | 35.91 | 2.10 | 2.52 | < 0.02 | < 0.02 | 62.85 |
| 22 | 291 | < 0.02 | < 0.02 | 36.10 | 2.30 | 2.53 | < 0.02 | < 0.02 | 68.97 |
| 20 | 345.5 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 345.6 | 176.68 | 34.525 | 35.90 | 2.33 | 2.52 | < 0.02 | < 0.02 | 73.06 |
| 19 | 520.2 | 179.00 | 34.631 | 34.29 | 2.31 | 2.41 | < 0.02 | < 0.02 | 77.70 |
| 18 | 650.9 | 181.06 | 34.668 | 33.83 | 2.18 | 2.38 | < 0.02 | < 0.02 | 81.65 |
| 16 | 800.4 | < 0.02 | < 0.02 | < 0.02 | 2.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 800.4 | 188.78 | 34.712 | 32.61 | 2.12 | 2.29 | < 0.02 | < 0.02 | 83.39 |
| 15 | 950.4 | 193.11 | 34.730 | 32.05 | 2.01 | 2.26 | < 0.02 | < 0.02 | 86.11 |
| 14 | 1101.3 | 197.00 | 34.739 | 31.72 | 1.93 | 2.23 | < 0.02 | < 0.02 | 88.19 |
| 13 | 1300.8 | 178.06 | 34.743 | 31.67 | 1.74 | 2.23 | < 0.02 | < 0.02 | 94.28 |
| 12 | 1500.8 | 203.07 | 34.740 | 31.86 | 1.56 | 2.25 | < 0.02 | < 0.02 | 99.73 |
| 11 | 1750.2 | 206.02 | 34.734 | 32.15 | 1.36 | 2.26 | < 0.02 | < 0.02 | 106.41 |
| 10 | 2000.5 | 208.08 | 34.727 | 32.46 | 1.19 | 2.29 | < 0.02 | < 0.02 | 111.84 |
| 9 | 2300.4 | 210.62 | 34.719 | 32.75 | 1.01 | 2.31 | < 0.02 | < 0.02 | 117.92 |
| 8 | 2300.4 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2600 | 212.72 | 34.712 | 32.95 | 0.89 | 2.33 | < 0.02 | < 0.02 | 121.70 |
| 6 | 2900.3 | 214.46 | 34.706 | 33.05 | 0.81 | 2.33 | < 0.02 | < 0.02 | 124.31 |
| 5 | 3202.5 | 217.50 | 34.700 | 33.13 | 0.71 | 2.34 | < 0.02 | < 0.02 | 127.23 |
| 3 | 3461.6 | < 0.02 | < 0.02 | < 0.02 | 0.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 3461.9 | 218.30 | 34.698 | 33.16 | 0.68 | 2.35 | < 0.02 | < 0.02 | 128.53 |
| 2 | 3523.6 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3523.8 | 218.62 | 34.698 | 33.19 | 0.69 | 2.34 | < 0.02 | < 0.02 | 128.34 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
| Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |