Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 68
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-09 08:56 to 2018-11-09 11:40 UTC
Where: 57° 15.7' S 156° 07.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|---|
| 36 | 15.1 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 35 | 15.3 | 342.95 | 33.790 | 27.68 | 1.91 | 1.91 | 0.22 | 0.22 | 16.43 | 
| 34 | 30.4 | 343.09 | 33.790 | 27.65 | 1.90 | 1.91 | 0.22 | 0.22 | 16.51 | 
| 33 | 54.7 | 343.18 | 33.791 | 27.67 | 1.90 | 1.92 | 0.24 | 0.22 | 16.60 | 
| 31 | 85.1 | 348.00 | 33.810 | 28.36 | 1.38 | 1.97 | 0.30 | 0.21 | 20.87 | 
| 32 | 85.1 | < 0.02 | < 0.02 | < 0.02 | 1.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 30 | 99.7 | 350.10 | 33.837 | 29.01 | 0.86 | 2.02 | 0.29 | 0.19 | 23.87 | 
| 29 | 120 | 345.36 | 33.862 | 29.61 | 0.60 | 2.06 | 0.28 | 0.18 | 26.79 | 
| 28 | 160.2 | 309.46 | 33.996 | 31.68 | 0.68 | 2.20 | 0.18 | 0.14 | 37.44 | 
| 27 | 210.2 | 222.37 | 34.290 | 35.30 | 1.84 | 2.43 | < 0.02 | 0.02 | 55.75 | 
| 25 | 280.1 | 193.52 | 34.422 | 36.23 | 2.14 | 2.50 | < 0.02 | < 0.02 | 66.27 | 
| 26 | 280.5 | < 0.02 | < 0.02 | < 0.02 | 2.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 24 | 459.6 | < 0.02 | < 0.02 | < 0.02 | 2.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 23 | 459.6 | 177.08 | 34.597 | 35.17 | 2.31 | 2.44 | < 0.02 | < 0.02 | 77.00 | 
| 22 | 552.5 | 178.11 | 34.631 | 34.60 | 2.28 | 2.40 | < 0.02 | < 0.02 | 78.74 | 
| 20 | 660.6 | 182.13 | 34.672 | 33.73 | 2.22 | 2.34 | < 0.02 | < 0.02 | 80.88 | 
| 21 | 660.9 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 19 | 879.9 | 190.03 | 34.718 | 32.58 | 2.11 | 2.26 | < 0.02 | < 0.02 | 83.72 | 
| 18 | 1037.7 | 194.54 | 34.736 | 31.97 | 2.01 | 2.22 | < 0.02 | < 0.02 | 86.90 | 
| 16 | 1220.6 | 198.61 | 34.743 | 31.79 | 1.89 | 2.21 | < 0.02 | < 0.02 | 89.53 | 
| 17 | 1220.8 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 14 | 1441 | 201.73 | 34.744 | 31.79 | 1.71 | 2.21 | < 0.02 | < 0.02 | 95.19 | 
| 15 | 1441 | < 0.02 | < 0.02 | < 0.02 | 1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 13 | 1649.6 | 203.92 | 34.740 | 31.96 | 1.53 | 2.22 | < 0.02 | < 0.02 | 99.75 | 
| 11 | 1881.1 | 206.65 | 34.734 | 32.26 | 1.35 | 2.25 | < 0.02 | < 0.02 | 106.16 | 
| 12 | 1881.3 | < 0.02 | < 0.02 | < 0.02 | 1.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 10 | 2091.5 | 208.70 | 34.726 | 32.52 | 1.18 | 2.27 | < 0.02 | < 0.02 | 111.90 | 
| 9 | 2340.6 | 210.58 | 34.718 | 32.84 | 1.02 | 2.29 | < 0.02 | < 0.02 | 117.38 | 
| 7 | 2590.6 | 213.08 | 34.711 | 33.07 | 0.88 | 2.31 | < 0.02 | < 0.02 | 121.61 | 
| 8 | 2590.8 | < 0.02 | < 0.02 | < 0.02 | 0.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 6 | 2842.3 | 215.94 | 34.706 | 33.12 | 0.78 | 2.32 | < 0.02 | < 0.02 | 124.16 | 
| 5 | 3210.8 | 218.97 | 34.697 | 33.28 | 0.64 | 2.33 | < 0.02 | < 0.02 | 128.26 | 
| 3 | 3430.1 | 220.45 | 34.693 | 33.32 | 0.58 | 2.33 | < 0.02 | < 0.02 | 130.30 | 
| 4 | 3430.4 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2 | 3479.4 | < 0.02 | < 0.02 | < 0.02 | 0.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1 | 3479.4 | 220.98 | 34.692 | 33.37 | 0.55 | 2.33 | < 0.02 | < 0.02 | 130.84 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) | 
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) | 
| Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
| Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) | 
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) | 
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) | 
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) | 
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |