Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 44
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-01 22:07 to 2018-11-02 00:58 UTC
Where: 56° 04.3' S 153° 23.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number | Pressure | Oxygen (µM) | Salinity (psu) | Nitrate (µM) | Temperature (deg C) | Orthophosphate (µM) | Ammonia (µM) | Nitrite (µM) | Silicate (µM) | 
|---|---|---|---|---|---|---|---|---|---|
| 35 | 10.5 | 349.87 | 33.809 | 28.43 | 1.37 | 1.99 | 0.22 | 0.20 | 21.50 | 
| 36 | 11.4 | < 0.02 | < 0.02 | < 0.02 | 1.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 34 | 25 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 33 | 25 | 350.19 | 33.809 | 28.47 | 1.35 | 1.99 | 0.23 | 0.20 | 21.61 | 
| 32 | 50.7 | 350.50 | 33.810 | 28.50 | 1.35 | 2.01 | 0.23 | 0.20 | 21.75 | 
| 31 | 79.7 | < 0.02 | < 0.02 | < 0.02 | 1.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 30 | 80.1 | 351.08 | 33.821 | 28.75 | 1.05 | 2.01 | 0.25 | 0.19 | 23.05 | 
| 29 | 100.5 | 349.65 | 33.857 | 29.37 | 0.36 | 2.07 | 0.20 | 0.17 | 26.72 | 
| 28 | 126 | 347.86 | 33.877 | 29.69 | 0.25 | 2.10 | 0.23 | 0.16 | 29.26 | 
| 26 | 151.5 | < 0.02 | < 0.02 | < 0.02 | 0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 27 | 151.8 | 349.12 | 33.889 | 29.91 | 0.12 | 2.11 | 0.28 | 0.17 | 31.81 | 
| 25 | 201.5 | 309.90 | 34.012 | 31.65 | 0.49 | 2.23 | 0.20 | 0.12 | 39.79 | 
| 23 | 281.9 | 216.25 | 34.341 | 35.42 | 1.59 | 2.48 | < 0.02 | 0.04 | 62.87 | 
| 24 | 282.2 | < 0.02 | < 0.02 | < 0.02 | 1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 22 | 372.2 | 178.51 | 34.520 | 35.93 | 2.30 | 2.52 | < 0.02 | < 0.02 | 73.14 | 
| 20 | 461.9 | 176.59 | 34.572 | 35.45 | 2.31 | 2.49 | < 0.02 | < 0.02 | 75.98 | 
| 21 | 462.3 | < 0.02 | < 0.02 | < 0.02 | 2.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 19 | 562.5 | 179.45 | 34.634 | 34.24 | 2.39 | 2.41 | < 0.02 | < 0.02 | 76.99 | 
| 18 | 622.1 | 181.23 | 34.652 | 33.97 | 2.33 | 2.39 | < 0.02 | < 0.02 | 78.43 | 
| 17 | 751.3 | < 0.02 | < 0.02 | < 0.02 | 2.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 16 | 751.3 | 183.33 | 34.682 | 33.59 | 2.18 | 2.36 | < 0.02 | < 0.02 | 82.33 | 
| 15 | 902 | 187.89 | 34.709 | 32.81 | 2.13 | 2.30 | < 0.02 | < 0.02 | 83.81 | 
| 14 | 1051.8 | 193.38 | 34.730 | 32.06 | 2.09 | 2.25 | < 0.02 | < 0.02 | 84.99 | 
| 13 | 1202.3 | 197.09 | 34.740 | 31.77 | 1.96 | 2.23 | < 0.02 | < 0.02 | 88.11 | 
| 11 | 1402.6 | 200.13 | 34.745 | 31.62 | 1.84 | 2.22 | < 0.02 | < 0.02 | 91.44 | 
| 12 | 1403.1 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 10 | 1702.7 | 204.06 | 34.740 | 31.94 | 1.53 | 2.25 | < 0.02 | < 0.02 | 101.42 | 
| 9 | 2000.6 | 208.34 | 34.729 | 32.46 | 1.23 | 2.28 | < 0.02 | < 0.02 | 111.26 | 
| 8 | 2301.4 | 211.25 | 34.718 | 32.82 | 0.99 | 2.32 | < 0.02 | < 0.02 | 118.23 | 
| 7 | 2602.8 | 213.88 | 34.710 | 33.00 | 0.84 | 2.33 | < 0.02 | < 0.02 | 123.32 | 
| 6 | 2901.3 | 216.56 | 34.702 | 33.19 | 0.72 | 2.34 | < 0.02 | < 0.02 | 127.38 | 
| 5 | 3201.1 | 219.20 | 34.696 | 33.33 | 0.61 | 2.35 | < 0.02 | < 0.02 | 130.15 | 
| 4 | 3550.4 | < 0.02 | < 0.02 | < 0.02 | 0.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 3 | 3550.5 | 221.74 | 34.691 | 33.39 | 0.54 | 2.36 | < 0.02 | < 0.02 | 132.20 | 
| 1 | 3610.2 | 221.56 | 34.691 | 33.37 | 0.54 | 2.36 | < 0.02 | < 0.02 | 132.33 | 
| 2 | 3610.3 | < 0.02 | < 0.02 | < 0.02 | 0.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) | 
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) | 
| Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
| Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) | 
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) | 
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) | 
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) | 
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |