Deployment Details
Survey: - IN2018_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 34
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-10-30 07:56 to 2018-10-30 11:16 UTC
Where: 55° 27.5' S 153° 21.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 15.9 | < 0.02 | < 0.02 | < 0.02 | 5.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 16.2 | 317.14 | 33.975 | 23.66 | 5.10 | 1.63 | 0.06 | 0.20 | 6.58 |
35 | 16.2 | < 0.02 | < 0.02 | < 0.02 | 5.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 35.3 | 317.27 | 33.974 | 23.64 | 5.10 | 1.64 | 0.08 | 0.20 | 6.57 |
33 | 35.7 | < 0.02 | < 0.02 | < 0.02 | 5.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 55.6 | < 0.02 | < 0.02 | < 0.02 | 5.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 55.6 | 317.32 | 33.975 | 23.67 | 5.09 | 1.64 | 0.07 | 0.20 | 6.67 |
29 | 89.2 | 315.66 | 33.953 | 25.08 | 4.47 | 1.75 | 0.17 | 0.22 | 7.89 |
28 | 120.4 | 311.02 | 33.973 | 25.44 | 4.43 | 1.77 | 0.16 | 0.21 | 8.68 |
27 | 150.4 | 308.52 | 33.978 | 25.63 | 4.39 | 1.79 | 0.14 | 0.20 | 9.10 |
25 | 180.4 | 299.32 | 34.004 | 26.03 | 4.47 | 1.80 | 0.05 | 0.16 | 9.92 |
26 | 180.4 | < 0.02 | < 0.02 | < 0.02 | 4.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 209.8 | 265.15 | 34.159 | 26.70 | 5.14 | 1.84 | < 0.02 | 0.02 | 13.46 |
23 | 299.9 | 243.40 | 34.229 | 29.28 | 4.69 | 2.01 | < 0.02 | < 0.02 | 20.86 |
22 | 450.1 | 226.61 | 34.267 | 31.86 | 3.95 | 2.20 | < 0.02 | < 0.02 | 31.53 |
21 | 559.4 | 213.08 | 34.308 | 33.51 | 3.39 | 2.32 | < 0.02 | < 0.02 | 41.66 |
20 | 700.7 | 189.45 | 34.423 | 35.15 | 2.96 | 2.44 | < 0.02 | < 0.02 | 58.16 |
19 | 850 | 182.75 | 34.476 | 35.47 | 2.78 | 2.47 | < 0.02 | < 0.02 | 65.08 |
17 | 1051.1 | 178.29 | 34.586 | 34.90 | 2.55 | 2.44 | < 0.02 | < 0.02 | 73.64 |
18 | 1051.6 | < 0.02 | < 0.02 | < 0.02 | 2.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1393.2 | 186.28 | 34.694 | 33.01 | 2.31 | 2.30 | < 0.02 | < 0.02 | 80.00 |
15 | 1642.9 | 192.62 | 34.728 | 32.26 | 2.11 | 2.24 | < 0.02 | < 0.02 | 85.24 |
13 | 1891.2 | 198.92 | 34.744 | 31.77 | 1.92 | 2.22 | < 0.02 | < 0.02 | 90.09 |
14 | 1891.3 | 199.23 | 34.743 | 31.74 | 1.91 | 2.21 | < 0.02 | < 0.02 | 89.93 |
12 | 2052.2 | < 0.02 | < 0.02 | < 0.02 | 1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2052.4 | 201.64 | 34.744 | 31.81 | 1.76 | 2.22 | < 0.02 | < 0.02 | 94.33 |
10 | 2190.6 | 203.52 | 34.741 | 31.93 | 1.62 | 2.23 | < 0.02 | < 0.02 | 98.63 |
9 | 2429.6 | < 0.02 | < 0.02 | < 0.02 | 1.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 2430 | 206.42 | 34.734 | 32.19 | 1.43 | 2.25 | < 0.02 | < 0.02 | 104.63 |
7 | 2720 | 209.55 | 34.721 | 32.60 | 1.11 | 2.28 | < 0.02 | < 0.02 | 115.44 |
6 | 3109.4 | 212.63 | 34.711 | 32.94 | 0.94 | 2.30 | < 0.02 | < 0.02 | 122.11 |
5 | 3498.9 | 216.07 | 34.704 | 33.10 | 0.81 | 2.32 | < 0.02 | < 0.02 | 125.98 |
3 | 3781 | 217.59 | 34.700 | 33.11 | 0.75 | 2.32 | < 0.02 | < 0.02 | 127.98 |
4 | 3781.1 | < 0.02 | < 0.02 | < 0.02 | 0.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3846.9 | 217.72 | 34.699 | 33.12 | 0.73 | 2.33 | < 0.02 | < 0.02 | 128.47 |
2 | 3846.9 | < 0.02 | < 0.02 | < 0.02 | 0.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |