Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-10-21 19:48 to 2018-10-21 23:29 UTC
Where: 54° 49.6' S 149° 04.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|---|
| 36 | 10.3 | 326.38 | 33.896 | 25.33 | 4.15 | 1.74 | 0.04 | 0.21 | 8.11 | 
| 35 | 11 | < 0.02 | < 0.02 | < 0.02 | 4.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 33 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 4.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 34 | 30.7 | 325.80 | 33.904 | 25.36 | 4.12 | 1.74 | 0.04 | 0.21 | 8.05 | 
| 32 | 60 | 327.37 | 33.897 | 25.46 | 3.98 | 1.75 | 0.08 | 0.21 | 8.21 | 
| 31 | 60.8 | < 0.02 | < 0.02 | < 0.02 | 3.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 29 | 91.8 | < 0.02 | < 0.02 | < 0.02 | 3.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 30 | 91.9 | 331.03 | 33.869 | 26.02 | 3.38 | 1.80 | 0.16 | 0.21 | 8.81 | 
| 27 | 116 | < 0.02 | < 0.02 | < 0.02 | 3.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 28 | 116 | 328.93 | 33.871 | 26.00 | 3.33 | 1.82 | 0.19 | 0.22 | 9.02 | 
| 26 | 140 | 328.35 | 33.867 | 26.46 | 3.14 | 1.83 | 0.18 | 0.22 | 9.54 | 
| 25 | 140 | < 0.02 | < 0.02 | < 0.02 | 3.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 24 | 174.1 | 314.90 | 33.936 | 26.81 | 3.41 | 1.85 | 0.09 | 0.19 | 11.02 | 
| 23 | 198.4 | 290.70 | 34.027 | 27.72 | 3.74 | 1.90 | < 0.02 | 0.09 | 14.17 | 
| 22 | 250.3 | 289.40 | 34.030 | 29.27 | 3.13 | 2.01 | < 0.02 | < 0.02 | 19.05 | 
| 21 | 300.8 | 263.54 | 34.131 | 30.25 | 3.56 | 2.07 | < 0.02 | < 0.02 | 23.34 | 
| 19 | 401.7 | < 0.02 | < 0.02 | < 0.02 | 2.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 20 | 401.7 | 262.74 | 34.131 | 32.04 | 2.58 | 2.20 | < 0.02 | < 0.02 | 32.52 | 
| 18 | 504.4 | 230.05 | 34.240 | 33.74 | 2.65 | 2.33 | < 0.02 | < 0.02 | 42.79 | 
| 17 | 648.7 | 192.27 | 34.408 | 35.00 | 2.94 | 2.42 | < 0.02 | < 0.02 | 56.24 | 
| 16 | 799.4 | 182.89 | 34.478 | 35.36 | 2.66 | 2.45 | < 0.02 | < 0.02 | 65.14 | 
| 15 | 952.8 | 177.71 | 34.566 | 35.02 | 2.53 | 2.42 | < 0.02 | < 0.02 | 72.01 | 
| 14 | 1107.8 | 180.39 | 34.633 | 33.87 | 2.46 | 2.34 | < 0.02 | < 0.02 | 75.09 | 
| 13 | 1304.3 | 185.52 | 34.687 | 32.95 | 2.32 | 2.27 | < 0.02 | < 0.02 | 78.87 | 
| 12 | 1500.6 | 192.31 | 34.723 | 32.00 | 2.19 | 2.22 | < 0.02 | < 0.02 | 81.81 | 
| 11 | 1506.6 | < 0.02 | < 0.02 | < 0.02 | 2.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 10 | 1754.7 | 198.12 | 34.743 | 31.53 | 2.01 | 2.18 | < 0.02 | < 0.02 | 86.67 | 
| 9 | 2003 | 201.47 | 34.744 | 31.64 | 1.78 | 2.20 | < 0.02 | < 0.02 | 94.78 | 
| 8 | 2305.5 | 204.23 | 34.737 | 32.06 | 1.49 | 2.23 | < 0.02 | < 0.02 | 104.71 | 
| 7 | 2605.6 | 206.65 | 34.727 | 32.40 | 1.25 | 2.26 | < 0.02 | < 0.02 | 112.52 | 
| 6 | 2903.9 | 215.49 | 34.719 | 32.65 | 1.07 | 2.28 | < 0.02 | < 0.02 | 117.49 | 
| 5 | 3205.8 | 210.53 | 34.716 | 32.77 | 1.03 | 2.29 | < 0.02 | < 0.02 | 120.07 | 
| 4 | 3503.6 | 213.17 | 34.710 | 32.83 | 0.94 | 2.30 | < 0.02 | < 0.02 | 122.12 | 
| 3 | 3839.2 | 215.36 | 34.704 | 33.01 | 0.85 | 2.30 | < 0.02 | < 0.02 | 124.87 | 
| 1 | 3917.5 | 215.85 | 34.703 | 32.97 | 0.84 | 2.30 | < 0.02 | < 0.02 | 125.18 | 
| 2 | 3920.3 | < 0.02 | < 0.02 | < 0.02 | 0.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) | 
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) | 
| Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
| Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) | 
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) | 
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) | 
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) | 
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |