Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-10-01 07:51 to 2018-10-01 12:04 UTC
Where: 47° 03.9' S 141° 52.5' E
Maximum Depth (m): 4624.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.3 | 282.88 | 34.653 | 12.68 | 9.45 | 0.96 | < 0.02 | 0.25 | 2.46 |
35 | 6.5 | 282.93 | 34.653 | 12.73 | 9.44 | 0.96 | < 0.02 | 0.25 | 2.49 |
33 | 30.9 | 283.02 | 34.654 | 12.73 | 9.46 | 0.96 | < 0.02 | 0.24 | 2.52 |
34 | 31.6 | 282.70 | 34.644 | 12.74 | 9.46 | 0.96 | < 0.02 | 0.24 | 2.44 |
32 | 51.4 | 282.79 | 34.655 | 12.70 | 9.48 | 0.97 | < 0.02 | 0.24 | 2.48 |
31 | 51.6 | 282.66 | 34.655 | 12.70 | 9.48 | 0.97 | < 0.02 | 0.24 | 2.45 |
29 | 100.3 | 282.75 | 34.654 | 12.72 | 9.47 | 0.97 | < 0.02 | 0.24 | 2.48 |
30 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 9.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 124.5 | 282.88 | 34.654 | 12.70 | 9.48 | 0.97 | < 0.02 | 0.24 | 2.45 |
27 | 151.4 | 282.66 | 34.656 | 12.69 | 9.49 | 0.97 | < 0.02 | 0.24 | 2.46 |
26 | 175.7 | 281.86 | 34.660 | 12.69 | 9.51 | 0.97 | < 0.02 | 0.25 | 2.44 |
24 | 199.9 | 281.77 | 34.663 | 12.65 | 9.53 | 0.97 | < 0.02 | 0.25 | 2.45 |
25 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 9.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 225.2 | 281.50 | 34.663 | 12.52 | 9.53 | 0.96 | < 0.02 | 0.25 | 2.43 |
22 | 251.2 | 280.56 | 34.678 | 12.59 | 9.60 | 0.96 | < 0.02 | 0.25 | 2.42 |
21 | 300.1 | < 0.02 | < 0.02 | < 0.02 | 9.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 300.2 | 256.80 | 34.673 | 15.77 | 9.34 | 1.14 | < 0.02 | < 0.02 | 4.14 |
19 | 349.7 | 260.37 | 34.650 | 15.96 | 9.15 | 1.15 | < 0.02 | < 0.02 | 4.17 |
17 | 480.9 | 266.54 | 34.601 | 16.30 | 8.81 | 1.18 | < 0.02 | < 0.02 | 4.27 |
18 | 480.9 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 601.7 | 252.42 | 34.513 | 19.39 | 8.19 | 1.37 | < 0.02 | < 0.02 | 6.40 |
15 | 800.7 | < 0.02 | < 0.02 | < 0.02 | 6.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 800.8 | 214.15 | 34.429 | 26.02 | 6.78 | 1.80 | < 0.02 | < 0.02 | 16.31 |
13 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 4.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1000.7 | 206.69 | 34.357 | 30.70 | 4.90 | 2.12 | < 0.02 | < 0.02 | 31.08 |
11 | 1201.5 | 189.94 | 34.407 | 33.45 | 3.82 | 2.34 | < 0.02 | < 0.02 | 50.20 |
10 | 1400.2 | 178.06 | 34.478 | 34.89 | 3.16 | 2.44 | < 0.02 | < 0.02 | 64.31 |
9 | 1600.4 | 173.11 | 34.562 | 34.91 | 2.79 | 2.44 | < 0.02 | < 0.02 | 74.07 |
8 | 1799.9 | 174.76 | 34.629 | 34.24 | 2.57 | 2.40 | < 0.02 | < 0.02 | 79.26 |
6 | 2000.3 | 178.55 | 34.677 | 33.47 | 2.42 | 2.35 | < 0.02 | < 0.02 | 83.71 |
7 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 2.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2500.2 | 182.40 | 34.730 | 33.05 | 2.08 | 2.33 | < 0.02 | < 0.02 | 99.59 |
4 | 3000.8 | 190.17 | 34.735 | 32.88 | 1.77 | 2.32 | < 0.02 | < 0.02 | 108.16 |
3 | 3501.1 | 199.14 | 34.731 | 32.74 | 1.49 | 2.30 | < 0.02 | < 0.02 | 113.61 |
2 | 4000 | 204.10 | 34.724 | 32.91 | 1.28 | 2.32 | < 0.02 | < 0.02 | 119.13 |
1 | 4624.3 | 208.48 | 34.712 | 33.23 | 1.07 | 2.33 | < 0.02 | < 0.02 | 124.20 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |