Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-10-01 00:44 to 2018-10-01 02:45 UTC
Where: 47° 02.5' S 141° 51.6' E
Maximum Depth (m): 1500.8
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 6.9 | 282.48 | 34.646 | 12.81 | 9.44 | 0.98 | < 0.02 | 0.25 | 2.57 |
33 | 15.2 | < 0.02 | < 0.02 | 12.82 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.57 |
34 | 16.3 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 31 | < 0.02 | < 0.02 | 12.80 | 9.44 | 0.98 | < 0.02 | 0.25 | 2.55 |
32 | 31.5 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.2 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 41.3 | < 0.02 | < 0.02 | 12.82 | 9.44 | 0.98 | < 0.02 | 0.25 | 2.53 |
28 | 51.6 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 52.5 | < 0.02 | < 0.02 | 12.81 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.52 |
26 | 58.2 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 58.3 | < 0.02 | < 0.02 | 12.80 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.56 |
23 | 68.8 | < 0.02 | < 0.02 | 12.82 | 9.43 | 0.98 | < 0.02 | 0.24 | 2.54 |
24 | 69.1 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 80.4 | < 0.02 | < 0.02 | 12.81 | 9.43 | 0.98 | < 0.02 | 0.24 | 2.59 |
21 | 90.2 | < 0.02 | < 0.02 | 12.82 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.59 |
19 | 99 | 282.08 | 34.647 | 12.78 | 9.45 | 0.98 | < 0.02 | 0.25 | 2.54 |
20 | 99.1 | < 0.02 | < 0.02 | < 0.02 | 9.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 126.1 | < 0.02 | < 0.02 | 12.81 | 9.43 | 0.98 | < 0.02 | 0.24 | 2.60 |
17 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 150.8 | < 0.02 | < 0.02 | 12.79 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.58 |
15 | 175.6 | < 0.02 | < 0.02 | 12.84 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.61 |
14 | 201.9 | < 0.02 | < 0.02 | < 0.02 | 9.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 202 | 282.03 | 34.642 | 12.84 | 9.44 | 0.98 | < 0.02 | 0.24 | 2.63 |
12 | 301.7 | 259.12 | 34.662 | 15.77 | 9.27 | 1.14 | < 0.02 | < 0.02 | 4.23 |
11 | 400.9 | 264.97 | 34.620 | 15.92 | 8.99 | 1.16 | < 0.02 | < 0.02 | 4.22 |
10 | 499.9 | 264.71 | 34.590 | 16.61 | 8.75 | 1.21 | < 0.02 | < 0.02 | 4.59 |
9 | 601.8 | < 0.02 | < 0.02 | 19.62 | 8.06 | 1.39 | < 0.02 | < 0.02 | 6.69 |
8 | 801.5 | 213.35 | 34.434 | 25.93 | 6.81 | 1.80 | < 0.02 | < 0.02 | 16.51 |
7 | 899.9 | 205.04 | 34.401 | 28.73 | 5.85 | 2.00 | < 0.02 | < 0.02 | 24.64 |
6 | 1000.4 | < 0.02 | < 0.02 | 30.70 | 4.86 | 2.14 | < 0.02 | < 0.02 | 31.38 |
5 | 1100.3 | 196.15 | 34.388 | 32.08 | 4.41 | 2.25 | < 0.02 | < 0.02 | 41.33 |
4 | 1200.8 | < 0.02 | < 0.02 | 33.18 | 3.96 | 2.33 | < 0.02 | < 0.02 | 49.52 |
3 | 1300.9 | 183.56 | 34.439 | 34.24 | 3.50 | 2.42 | < 0.02 | < 0.02 | 57.52 |
2 | 1399.6 | < 0.02 | < 0.02 | 34.84 | 3.20 | 2.46 | < 0.02 | < 0.02 | 63.56 |
1 | 1500.8 | 175.16 | 34.512 | 35.04 | 3.00 | 2.47 | < 0.02 | < 0.02 | 69.29 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |