Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-28 23:32 to 2018-09-29 01:36 UTC
Where: 46° 20.2' S 148° 05.9' E
Maximum Depth (m): 1499.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 8.4 | 286.81 | 34.564 | 13.66 | 9.13 | 1.02 | < 0.02 | 0.24 | 2.61 |
36 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 9.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 9.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 16.3 | < 0.02 | < 0.02 | 13.64 | 9.13 | 1.02 | < 0.02 | 0.23 | 2.59 |
32 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 31.5 | < 0.02 | < 0.02 | 13.66 | 9.14 | 1.02 | < 0.02 | 0.24 | 2.61 |
29 | 39.9 | < 0.02 | < 0.02 | 13.64 | 9.14 | 1.02 | < 0.02 | 0.24 | 2.57 |
30 | 41 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 51.3 | < 0.02 | < 0.02 | 13.66 | 9.13 | 1.03 | < 0.02 | 0.24 | 2.60 |
28 | 51.3 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 60.2 | < 0.02 | < 0.02 | 13.69 | 9.14 | 1.03 | < 0.02 | 0.23 | 2.58 |
26 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 69.3 | < 0.02 | < 0.02 | 13.67 | 9.14 | 1.02 | < 0.02 | 0.23 | 2.59 |
24 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 80.9 | < 0.02 | < 0.02 | 13.65 | 9.14 | 1.02 | < 0.02 | 0.23 | 2.57 |
21 | 91 | < 0.02 | < 0.02 | 13.69 | 9.14 | 1.02 | < 0.02 | 0.23 | 2.60 |
19 | 101.1 | 285.70 | 34.566 | 13.71 | 9.14 | 1.03 | < 0.02 | 0.23 | 2.60 |
20 | 101.2 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 125.9 | < 0.02 | < 0.02 | 13.85 | 9.14 | 1.03 | < 0.02 | 0.22 | 2.64 |
17 | 150.5 | < 0.02 | < 0.02 | 13.91 | 9.20 | 1.04 | < 0.02 | 0.17 | 2.66 |
16 | 175.8 | < 0.02 | < 0.02 | 13.98 | 9.27 | 1.04 | < 0.02 | 0.14 | 2.73 |
15 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 200.6 | < 0.02 | < 0.02 | 14.97 | 8.81 | 1.10 | < 0.02 | 0.06 | 2.83 |
13 | 301.1 | 266.85 | 34.602 | 15.56 | 9.11 | 1.13 | < 0.02 | 0.02 | 3.75 |
12 | 402.1 | 261.27 | 34.639 | 16.05 | 9.10 | 1.15 | < 0.02 | < 0.02 | 4.27 |
11 | 501.6 | 257.78 | 34.585 | 17.50 | 8.70 | 1.24 | < 0.02 | < 0.02 | 5.17 |
10 | 602.1 | 249.16 | 34.511 | 19.87 | 8.15 | 1.39 | < 0.02 | < 0.02 | 7.04 |
9 | 700.6 | < 0.02 | < 0.02 | 23.65 | 7.37 | 1.63 | < 0.02 | < 0.02 | 12.47 |
8 | 799.6 | 214.33 | 34.403 | 27.07 | 6.35 | 1.86 | < 0.02 | < 0.02 | 18.93 |
7 | 901.4 | 210.09 | 34.369 | 29.47 | 5.39 | 2.03 | < 0.02 | < 0.02 | 26.70 |
6 | 1000.8 | < 0.02 | < 0.02 | 31.20 | 4.74 | 2.16 | < 0.02 | < 0.02 | 34.89 |
5 | 1100.9 | 190.70 | 34.411 | 32.62 | 4.25 | 2.27 | < 0.02 | < 0.02 | 46.56 |
4 | 1201 | < 0.02 | < 0.02 | 33.54 | 3.91 | 2.34 | < 0.02 | < 0.02 | 55.04 |
3 | 1299.7 | 175.07 | 34.481 | 34.43 | 3.53 | 2.42 | < 0.02 | < 0.02 | 65.12 |
2 | 1402 | < 0.02 | < 0.02 | 34.84 | 3.29 | 2.44 | < 0.02 | < 0.02 | 70.26 |
1 | 1499.9 | 168.60 | 34.538 | 35.10 | 3.08 | 2.47 | < 0.02 | < 0.02 | 76.01 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |