Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-27 12:15 to 2018-09-27 14:22 UTC
Where: 45° 56.4' S 153° 37.6' E
Maximum Depth (m): 1502.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.5 | 270.96 | 34.953 | 10.95 | 10.67 | 0.83 | < 0.02 | 0.19 | 2.82 |
36 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 10.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15 | < 0.02 | < 0.02 | 10.96 | 10.67 | 0.82 | < 0.02 | 0.19 | 2.84 |
34 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 10.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 31.1 | < 0.02 | < 0.02 | < 0.02 | 10.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 31.1 | < 0.02 | < 0.02 | 10.97 | 10.68 | 0.83 | < 0.02 | 0.19 | 2.85 |
29 | 41.1 | < 0.02 | < 0.02 | 10.98 | 10.66 | 0.83 | < 0.02 | 0.19 | 2.83 |
30 | 41.2 | < 0.02 | < 0.02 | < 0.02 | 10.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 10.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 51.3 | < 0.02 | < 0.02 | 10.95 | 10.67 | 0.83 | < 0.02 | 0.18 | 2.80 |
25 | 60 | < 0.02 | < 0.02 | 11.02 | 10.65 | 0.83 | < 0.02 | 0.18 | 2.84 |
26 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 70.9 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 71.1 | < 0.02 | < 0.02 | 11.02 | 10.64 | 0.84 | < 0.02 | 0.18 | 2.82 |
22 | 80.6 | < 0.02 | < 0.02 | 11.03 | 10.64 | 0.84 | < 0.02 | 0.18 | 2.81 |
21 | 90.2 | < 0.02 | < 0.02 | 11.03 | 10.66 | 0.84 | < 0.02 | 0.19 | 2.83 |
19 | 100.6 | 269.75 | 34.953 | 11.01 | 10.67 | 0.83 | < 0.02 | 0.19 | 2.85 |
20 | 100.7 | < 0.02 | < 0.02 | < 0.02 | 10.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 124.2 | < 0.02 | < 0.02 | 11.00 | 10.68 | 0.83 | < 0.02 | 0.19 | 2.84 |
17 | 151.1 | < 0.02 | < 0.02 | < 0.02 | 10.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 151.1 | < 0.02 | < 0.02 | 10.97 | 10.69 | 0.83 | < 0.02 | 0.19 | 2.83 |
15 | 175.6 | < 0.02 | < 0.02 | 10.92 | 10.75 | 0.83 | < 0.02 | 0.19 | 2.84 |
14 | 201.2 | < 0.02 | < 0.02 | < 0.02 | 10.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 202 | 269.17 | 34.971 | 10.89 | 10.76 | 0.83 | < 0.02 | 0.18 | 2.85 |
12 | 301.2 | 266.98 | 34.963 | 11.18 | 10.73 | 0.85 | < 0.02 | 0.17 | 2.97 |
11 | 401.1 | 233.49 | 34.628 | 19.35 | 8.84 | 1.35 | < 0.02 | < 0.02 | 6.79 |
10 | 502 | 231.34 | 34.527 | 21.67 | 8.05 | 1.50 | < 0.02 | < 0.02 | 9.12 |
9 | 601.5 | < 0.02 | < 0.02 | 25.00 | 7.47 | 1.71 | < 0.02 | < 0.02 | 15.07 |
8 | 801.2 | 196.33 | 34.428 | 29.45 | 5.74 | 2.03 | < 0.02 | < 0.02 | 29.43 |
7 | 900.5 | 192.98 | 34.420 | 30.86 | 5.15 | 2.13 | < 0.02 | < 0.02 | 36.48 |
6 | 1000.8 | < 0.02 | < 0.02 | 32.16 | 4.57 | 2.23 | < 0.02 | < 0.02 | 44.78 |
5 | 1100.7 | 192.18 | 34.400 | 33.29 | 3.89 | 2.31 | < 0.02 | < 0.02 | 48.33 |
4 | 1201.6 | < 0.02 | < 0.02 | 34.11 | 3.64 | 2.38 | < 0.02 | < 0.02 | 58.35 |
3 | 1300.3 | 174.94 | 34.484 | 34.64 | 3.41 | 2.43 | < 0.02 | < 0.02 | 65.97 |
2 | 1401.2 | < 0.02 | < 0.02 | 35.04 | 3.13 | 2.45 | < 0.02 | < 0.02 | 71.62 |
1 | 1502.2 | 168.06 | 34.559 | 35.14 | 2.90 | 2.47 | < 0.02 | < 0.02 | 78.90 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |