Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-24 23:26 to 2018-09-25 03:20 UTC
Where: 45° 44.6' S 153° 32.4' E
Maximum Depth (m): 4538.8
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.5 | 272.48 | 34.941 | 10.84 | 10.64 | 0.82 | < 0.02 | 0.18 | 2.71 |
36 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 30 | < 0.02 | < 0.02 | 10.84 | 10.64 | 0.83 | < 0.02 | 0.18 | 2.75 |
31 | 31.1 | < 0.02 | < 0.02 | < 0.02 | 10.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 31.3 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 60.5 | < 0.02 | < 0.02 | < 0.02 | 10.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 60.9 | 272.12 | 34.940 | 10.86 | 10.64 | 0.83 | < 0.02 | 0.18 | 2.71 |
29 | 61 | < 0.02 | < 0.02 | < 0.02 | 10.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 78.4 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 78.5 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 78.6 | < 0.02 | < 0.02 | 10.84 | 10.64 | 0.83 | < 0.02 | 0.18 | 2.70 |
22 | 125 | < 0.02 | < 0.02 | < 0.02 | 10.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 125.1 | < 0.02 | < 0.02 | < 0.02 | 10.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 125.1 | < 0.02 | < 0.02 | 10.89 | 10.61 | 0.84 | < 0.02 | 0.18 | 2.72 |
20 | 175.1 | < 0.02 | < 0.02 | < 0.02 | 10.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 175.3 | 271.67 | 34.931 | 10.96 | 10.59 | 0.84 | < 0.02 | 0.18 | 2.72 |
19 | 175.3 | < 0.02 | < 0.02 | < 0.02 | 10.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 200.4 | < 0.02 | < 0.02 | 11.04 | 10.59 | 0.85 | < 0.02 | 0.18 | 2.76 |
17 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 10.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 10.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 301 | < 0.02 | < 0.02 | < 0.02 | 9.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 301 | 271.40 | 34.707 | 13.56 | 9.55 | 1.00 | < 0.02 | 0.04 | 2.98 |
15 | 301.1 | < 0.02 | < 0.02 | < 0.02 | 9.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 501.6 | 239.20 | 34.579 | 19.72 | 8.54 | 1.38 | 0.04 | < 0.02 | 7.00 |
11 | 752.8 | 207.36 | 34.450 | 26.52 | 6.80 | 1.81 | < 0.02 | < 0.02 | 17.92 |
10 | 1001.6 | 205.44 | 34.356 | 31.45 | 4.60 | 2.16 | < 0.02 | < 0.02 | 34.21 |
9 | 1250.2 | 190.48 | 34.409 | 34.07 | 3.52 | 2.36 | < 0.02 | < 0.02 | 52.33 |
8 | 1500.6 | 175.92 | 34.519 | 35.11 | 2.91 | 2.44 | < 0.02 | < 0.02 | 69.41 |
7 | 1751 | 175.16 | 34.610 | 34.46 | 2.60 | 2.40 | < 0.02 | < 0.02 | 76.75 |
6 | 2000.4 | 180.88 | 34.680 | 33.36 | 2.38 | 2.32 | < 0.02 | < 0.02 | 82.09 |
5 | 2500.2 | 192.71 | 34.735 | 32.19 | 2.01 | 2.24 | < 0.02 | < 0.02 | 92.26 |
4 | 3000.8 | 199.46 | 34.735 | 32.42 | 1.60 | 2.26 | < 0.02 | < 0.02 | 104.58 |
3 | 3500.1 | 205.04 | 34.722 | 32.90 | 1.24 | 2.29 | < 0.02 | < 0.02 | 114.57 |
2 | 4000 | 208.79 | 34.714 | 33.20 | 1.07 | 2.31 | < 0.02 | < 0.02 | 120.12 |
1 | 4538.8 | 211.56 | 34.708 | 33.22 | 1.01 | 2.31 | < 0.02 | < 0.02 | 123.07 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |