Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-24 00:15 to 2018-09-24 04:26 UTC
Where: 43° 51.7' S 153° 35.0' E
Maximum Depth (m): 4782.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 27 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 7.2 | 266.85 | 35.181 | 7.43 | 12.13 | 0.62 | 0.03 | 0.21 | 2.10 |
| 35 | 7.3 | < 0.02 | < 0.02 | 7.43 | 12.13 | 0.61 | 0.03 | 0.21 | 2.10 |
| 24 | 15.7 | < 0.02 | < 0.02 | 7.43 | 12.14 | 0.62 | 0.03 | 0.21 | 2.09 |
| 23 | 29.1 | < 0.02 | < 0.02 | 7.46 | 12.14 | 0.62 | 0.03 | 0.20 | 2.10 |
| 22 | 39.7 | < 0.02 | < 0.02 | 7.46 | 12.14 | 0.62 | 0.02 | 0.20 | 2.14 |
| 21 | 49 | < 0.02 | < 0.02 | 7.47 | 12.15 | 0.62 | 0.02 | 0.20 | 2.12 |
| 20 | 60.3 | < 0.02 | < 0.02 | 7.49 | 12.14 | 0.63 | 0.02 | 0.20 | 2.12 |
| 19 | 70.9 | < 0.02 | < 0.02 | 7.52 | 12.14 | 0.63 | 0.02 | 0.20 | 2.11 |
| 18 | 99.7 | 264.39 | 35.188 | 7.55 | 12.15 | 0.63 | 0.02 | 0.19 | 2.12 |
| 17 | 125 | < 0.02 | < 0.02 | 7.55 | 12.15 | 0.63 | 0.02 | 0.19 | 2.10 |
| 16 | 151.5 | 264.30 | 35.189 | 7.55 | 12.15 | 0.63 | 0.02 | 0.19 | 2.06 |
| 15 | 202.7 | 258.81 | 35.166 | 8.40 | 12.02 | 0.68 | 0.10 | 0.06 | 2.36 |
| 14 | 304 | 257.02 | 35.038 | 9.96 | 11.41 | 0.78 | < 0.02 | 0.03 | 2.64 |
| 13 | 499.4 | 246.89 | 34.661 | 16.74 | 9.31 | 1.19 | < 0.02 | < 0.02 | 4.61 |
| 12 | 750.8 | 223.53 | 34.553 | 21.71 | 8.24 | 1.51 | < 0.02 | < 0.02 | 9.48 |
| 11 | 1001.8 | 202.85 | 34.409 | 28.72 | 5.95 | 1.97 | < 0.02 | < 0.02 | 24.45 |
| 10 | 1251.2 | 187.53 | 34.425 | 32.28 | 4.49 | 2.25 | < 0.02 | < 0.02 | 45.94 |
| 9 | 1500.9 | 168.19 | 34.509 | 34.57 | 3.56 | 2.44 | < 0.02 | < 0.02 | 70.98 |
| 8 | 1749.8 | 164.53 | 34.581 | 35.17 | 2.85 | 2.49 | < 0.02 | < 0.02 | 83.51 |
| 7 | 1998.1 | 170.69 | 34.644 | 34.39 | 2.50 | 2.43 | < 0.02 | < 0.02 | 86.90 |
| 6 | 2498.6 | 184.36 | 34.714 | 32.98 | 2.09 | 2.32 | < 0.02 | < 0.02 | 93.98 |
| 5 | 2999.2 | 193.69 | 34.731 | 32.58 | 1.76 | 2.29 | < 0.02 | < 0.02 | 102.97 |
| 4 | 3499.7 | 199.59 | 34.726 | 32.89 | 1.40 | 2.31 | < 0.02 | < 0.02 | 112.46 |
| 3 | 4000.6 | 202.72 | 34.716 | 33.27 | 1.19 | 2.34 | < 0.02 | < 0.02 | 119.14 |
| 2 | 4501.3 | 205.44 | 34.713 | 33.25 | 1.13 | 2.34 | < 0.02 | < 0.02 | 121.72 |
| 1 | 4782.5 | 209.24 | 34.709 | 33.23 | 1.06 | 2.33 | < 0.02 | < 0.02 | 123.76 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
| Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |