Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 16
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-23 02:15 to 2018-09-23 06:29 UTC
Where: 42° 03.0' S 152° 59.9' E
Maximum Depth (m): 4774.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 7.8 | 268.01 | 35.267 | 6.78 | 12.70 | 0.57 | < 0.02 | 0.28 | 2.23 |
28 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 16.4 | < 0.02 | < 0.02 | 6.79 | 12.70 | 0.57 | < 0.02 | 0.29 | 2.24 |
23 | 28.7 | < 0.02 | < 0.02 | 6.77 | 12.73 | 0.57 | 0.02 | 0.28 | 2.19 |
22 | 39.4 | < 0.02 | < 0.02 | 6.78 | 12.74 | 0.57 | < 0.02 | 0.28 | 2.15 |
21 | 53 | < 0.02 | < 0.02 | 6.79 | 12.75 | 0.57 | 0.08 | 0.29 | 2.17 |
20 | 58.6 | < 0.02 | < 0.02 | 6.80 | 12.71 | 0.57 | < 0.02 | 0.28 | 2.23 |
19 | 71 | 268.59 | 35.265 | 6.83 | 12.70 | 0.57 | < 0.02 | 0.28 | 2.24 |
18 | 97.9 | 264.88 | 35.265 | 6.81 | 12.70 | 0.57 | 0.02 | 0.28 | 2.26 |
17 | 123.6 | < 0.02 | < 0.02 | 6.93 | 12.69 | 0.58 | 0.02 | 0.31 | 2.22 |
16 | 150.3 | 260.86 | 35.255 | 7.16 | 12.64 | 0.59 | 0.02 | 0.33 | 2.29 |
15 | 201.1 | 255.42 | 35.204 | 8.10 | 12.39 | 0.65 | < 0.02 | 0.14 | 2.52 |
14 | 301.2 | 247.96 | 35.036 | 10.52 | 11.52 | 0.80 | < 0.02 | 0.02 | 3.04 |
13 | 500.8 | 232.82 | 34.638 | 19.11 | 8.98 | 1.33 | < 0.02 | < 0.02 | 6.73 |
12 | 751.4 | 205.75 | 34.486 | 25.58 | 7.24 | 1.76 | < 0.02 | < 0.02 | 15.95 |
11 | 1000 | 193.29 | 34.425 | 30.36 | 5.39 | 2.10 | < 0.02 | < 0.02 | 33.85 |
10 | 1250 | 175.70 | 34.473 | 33.78 | 3.93 | 2.36 | < 0.02 | < 0.02 | 60.19 |
9 | 1500.1 | 162.52 | 34.556 | 35.26 | 3.11 | 2.49 | < 0.02 | < 0.02 | 81.68 |
8 | 1750.2 | 166.67 | 34.616 | 34.94 | 2.63 | 2.47 | < 0.02 | < 0.02 | 86.71 |
7 | 2001.6 | 174.04 | 34.670 | 34.09 | 2.35 | 2.39 | < 0.02 | < 0.02 | 89.90 |
6 | 2500.5 | 187.35 | 34.721 | 32.91 | 1.97 | 2.31 | < 0.02 | < 0.02 | 96.67 |
5 | 2999.8 | 195.08 | 34.730 | 32.79 | 1.65 | 2.30 | < 0.02 | < 0.02 | 105.67 |
4 | 3498.5 | 200.57 | 34.721 | 33.13 | 1.30 | 2.33 | < 0.02 | < 0.02 | 114.94 |
3 | 4001.6 | 202.98 | 34.715 | 33.38 | 1.16 | 2.34 | < 0.02 | < 0.02 | 119.63 |
2 | 4500.5 | 204.50 | 34.713 | 33.40 | 1.14 | 2.34 | < 0.02 | < 0.02 | 122.17 |
1 | 4774.2 | 209.06 | 34.710 | 33.30 | 1.09 | 2.33 | < 0.02 | < 0.02 | 123.09 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |