Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-22 00:41 to 2018-09-22 02:36 UTC
Where: 40° 07.8' S 153° 26.5' E
Maximum Depth (m): 1499.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 13.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.4 | 266.98 | 35.470 | 4.00 | 13.92 | 0.39 | 0.13 | 0.19 | 1.54 |
33 | 15.9 | < 0.02 | < 0.02 | 3.92 | 13.92 | 0.39 | 0.22 | 0.19 | 1.53 |
34 | 16 | < 0.02 | < 0.02 | < 0.02 | 13.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 29.4 | < 0.02 | < 0.02 | 4.03 | 13.90 | 0.40 | 0.13 | 0.20 | 1.54 |
32 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 13.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 39.1 | < 0.02 | < 0.02 | < 0.02 | 13.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 39.4 | < 0.02 | < 0.02 | 4.22 | 13.87 | 0.41 | 0.16 | 0.21 | 1.55 |
28 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 13.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50.5 | < 0.02 | < 0.02 | 4.36 | 13.80 | 0.42 | 0.17 | 0.21 | 1.61 |
26 | 59.3 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 60 | < 0.02 | < 0.02 | 4.42 | 13.78 | 0.42 | 0.20 | 0.22 | 1.59 |
23 | 70.1 | < 0.02 | < 0.02 | 4.56 | 13.74 | 0.43 | 0.27 | 0.23 | 1.57 |
24 | 70.2 | < 0.02 | < 0.02 | < 0.02 | 13.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 79.7 | < 0.02 | < 0.02 | 5.98 | 13.35 | 0.53 | 0.23 | 0.34 | 1.98 |
21 | 89.9 | < 0.02 | < 0.02 | 6.78 | 13.13 | 0.57 | 0.14 | 0.40 | 2.19 |
20 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 13.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 100.7 | 253.09 | 35.319 | 7.24 | 13.01 | 0.60 | 0.05 | 0.40 | 2.31 |
18 | 126 | < 0.02 | < 0.02 | < 0.02 | 12.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 126 | < 0.02 | < 0.02 | 7.28 | 12.81 | 0.60 | < 0.02 | 0.42 | 2.30 |
16 | 150.3 | < 0.02 | < 0.02 | 7.72 | 12.71 | 0.63 | < 0.02 | 0.25 | 2.39 |
15 | 176.4 | < 0.02 | < 0.02 | 8.23 | 12.54 | 0.66 | < 0.02 | 0.12 | 2.53 |
14 | 201.2 | < 0.02 | < 0.02 | 8.30 | 12.47 | 0.66 | < 0.02 | 0.05 | 2.48 |
13 | 298.1 | 235.90 | 34.928 | 14.05 | 10.93 | 1.01 | < 0.02 | 0.02 | 4.25 |
12 | 399.5 | 230.00 | 34.747 | 17.21 | 9.75 | 1.20 | < 0.02 | < 0.02 | 5.46 |
11 | 499.1 | 241.48 | 34.585 | 19.22 | 8.66 | 1.35 | < 0.02 | < 0.02 | 6.46 |
10 | 600.4 | 219.46 | 34.549 | 22.34 | 8.10 | 1.55 | < 0.02 | < 0.02 | 10.43 |
9 | 700.4 | < 0.02 | < 0.02 | 24.89 | 7.43 | 1.72 | < 0.02 | < 0.02 | 14.91 |
8 | 799.3 | 202.45 | 34.450 | 27.40 | 6.53 | 1.90 | < 0.02 | < 0.02 | 21.42 |
7 | 900.9 | 197.04 | 34.433 | 29.04 | 5.91 | 2.02 | < 0.02 | < 0.02 | 27.98 |
6 | 1000.7 | < 0.02 | < 0.02 | 30.65 | 5.28 | 2.14 | < 0.02 | < 0.02 | 37.07 |
5 | 1100.8 | 183.02 | 34.453 | 32.08 | 4.68 | 2.26 | < 0.02 | < 0.02 | 48.48 |
4 | 1201 | < 0.02 | < 0.02 | 33.19 | 4.22 | 2.35 | < 0.02 | < 0.02 | 58.46 |
3 | 1301.2 | 169.98 | 34.501 | 34.06 | 3.80 | 2.41 | < 0.02 | < 0.02 | 67.76 |
2 | 1401.3 | < 0.02 | < 0.02 | 34.76 | 3.47 | 2.47 | < 0.02 | < 0.02 | 77.14 |
1 | 1499.9 | 161.40 | 34.557 | 35.12 | 3.18 | 2.51 | < 0.02 | < 0.02 | 83.05 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |