Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-20 16:37 to 2018-09-20 20:46 UTC
Where: 40° 07.9' S 153° 26.7' E
Maximum Depth (m): 4938.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 13.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.5 | 264.39 | 35.435 | 4.63 | 13.65 | 0.43 | 0.05 | 0.18 | 1.54 |
35 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 13.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 13.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15.4 | < 0.02 | < 0.02 | 4.58 | 13.66 | 0.43 | 0.07 | 0.17 | 1.50 |
31 | 15.7 | < 0.02 | < 0.02 | < 0.02 | 13.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.6 | 262.34 | 35.418 | 5.16 | 13.57 | 0.46 | 0.07 | 0.20 | 1.66 |
29 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 13.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 41.1 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50.6 | < 0.02 | < 0.02 | 5.76 | 13.46 | 0.51 | 0.08 | 0.20 | 1.84 |
25 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 13.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 60.8 | < 0.02 | < 0.02 | 6.92 | 13.25 | 0.58 | 0.07 | 0.17 | 2.11 |
22 | 60.9 | < 0.02 | < 0.02 | < 0.02 | 13.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 61.1 | < 0.02 | < 0.02 | < 0.02 | 13.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 101.2 | 255.51 | 35.291 | 7.22 | 12.81 | 0.60 | 0.08 | 0.26 | 2.17 |
20 | 101.2 | < 0.02 | < 0.02 | < 0.02 | 12.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 101.3 | < 0.02 | < 0.02 | < 0.02 | 12.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 174.5 | < 0.02 | < 0.02 | < 0.02 | 12.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 174.6 | < 0.02 | < 0.02 | 7.66 | 12.54 | 0.62 | < 0.02 | 0.05 | 2.12 |
17 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 12.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 298.5 | < 0.02 | < 0.02 | < 0.02 | 11.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 298.6 | < 0.02 | < 0.02 | < 0.02 | 11.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 298.6 | 234.34 | 35.002 | 12.79 | 11.28 | 0.93 | < 0.02 | < 0.02 | 3.78 |
12 | 500.5 | 239.43 | 34.587 | 19.46 | 8.63 | 1.36 | < 0.02 | < 0.02 | 6.60 |
11 | 750.8 | 204.15 | 34.469 | 26.50 | 6.87 | 1.82 | < 0.02 | < 0.02 | 18.67 |
10 | 999.8 | 188.11 | 34.442 | 31.03 | 5.09 | 2.16 | < 0.02 | < 0.02 | 40.55 |
9 | 1251.4 | 172.39 | 34.562 | 33.76 | 3.93 | 2.38 | < 0.02 | < 0.02 | 64.72 |
8 | 1500.8 | 162.03 | 34.562 | 35.14 | 3.14 | 2.49 | < 0.02 | < 0.02 | 83.97 |
7 | 2000.8 | 172.44 | 34.665 | 34.22 | 2.37 | 2.41 | < 0.02 | < 0.02 | 92.27 |
6 | 2500.5 | 187.00 | 34.717 | 32.90 | 2.00 | 2.32 | < 0.02 | < 0.02 | 97.04 |
5 | 3000.7 | 195.97 | 34.728 | 32.70 | 1.60 | 2.30 | < 0.02 | < 0.02 | 107.12 |
4 | 3500.4 | 200.30 | 34.722 | 32.96 | 1.34 | 2.32 | < 0.02 | < 0.02 | 114.27 |
3 | 4001.2 | 202.94 | 34.716 | 33.26 | 1.18 | 2.34 | < 0.02 | < 0.02 | 119.46 |
2 | 4499.5 | 204.86 | 34.713 | 33.23 | 1.13 | 2.34 | < 0.02 | < 0.02 | 121.65 |
1 | 4938.2 | 206.02 | 34.713 | 33.26 | 1.16 | 2.34 | < 0.02 | < 0.02 | 122.30 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |