Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-19 00:28 to 2018-09-19 04:47 UTC
Where: 39° 47.0' S 150° 59.1' E
Maximum Depth (m): 4745
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
30 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6 | < 0.02 | < 0.02 | 3.93 | 14.33 | 0.39 | 0.06 | 0.20 | 1.57 |
31 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 6.5 | 261.58 | 35.521 | 3.92 | 14.33 | 0.39 | 0.05 | 0.20 | 1.57 |
28 | 15.9 | < 0.02 | < 0.02 | 3.92 | 14.33 | 0.39 | 0.06 | 0.20 | 1.52 |
27 | 30.7 | 258.23 | 35.520 | 3.96 | 14.33 | 0.40 | 0.19 | 0.20 | 1.55 |
26 | 39.9 | < 0.02 | < 0.02 | 3.99 | 14.33 | 0.39 | 0.10 | 0.21 | 1.51 |
25 | 50 | < 0.02 | < 0.02 | 4.05 | 14.32 | 0.39 | 0.09 | 0.22 | 1.54 |
24 | 60.6 | < 0.02 | < 0.02 | 4.23 | 14.25 | 0.42 | 0.16 | 0.23 | 1.60 |
23 | 69.2 | < 0.02 | < 0.02 | 4.44 | 14.18 | 0.43 | 0.18 | 0.25 | 1.66 |
22 | 79.2 | < 0.02 | < 0.02 | 4.31 | 14.10 | 0.43 | 0.24 | 0.29 | 1.60 |
21 | 98.4 | 256.89 | 35.489 | 4.54 | 14.09 | 0.44 | 0.20 | 0.31 | 1.61 |
20 | 124.4 | < 0.02 | < 0.02 | 6.63 | 13.83 | 0.56 | < 0.02 | 0.16 | 2.12 |
19 | 149.9 | < 0.02 | < 0.02 | 6.79 | 13.77 | 0.56 | < 0.02 | 0.13 | 2.18 |
18 | 199.5 | < 0.02 | < 0.02 | 9.77 | 12.92 | 0.75 | < 0.02 | 0.04 | 3.17 |
17 | 300.2 | < 0.02 | < 0.02 | 14.30 | 11.24 | 1.03 | < 0.02 | 0.02 | 4.90 |
16 | 500.2 | 216.07 | 34.631 | 21.09 | 8.66 | 1.46 | < 0.02 | < 0.02 | 9.44 |
15 | 751.4 | 198.38 | 34.462 | 27.69 | 6.46 | 1.91 | < 0.02 | < 0.02 | 23.43 |
14 | 999.3 | 183.33 | 34.454 | 31.84 | 4.77 | 2.22 | < 0.02 | < 0.02 | 46.91 |
13 | 1100 | 176.37 | 34.473 | 33.09 | 4.24 | 2.32 | < 0.02 | < 0.02 | 57.40 |
12 | 1251.1 | 166.36 | 34.517 | 34.33 | 3.66 | 2.43 | < 0.02 | < 0.02 | 72.08 |
11 | 1499.8 | 159.22 | 34.578 | 35.32 | 3.01 | 2.52 | < 0.02 | < 0.02 | 88.17 |
10 | 1750.6 | 164.89 | 34.636 | 34.86 | 2.54 | 2.48 | < 0.02 | < 0.02 | 92.87 |
9 | 2000.6 | 173.87 | 34.676 | 34.05 | 2.29 | 2.40 | < 0.02 | < 0.02 | 93.80 |
8 | 2249.3 | 182.08 | 34.705 | 33.15 | 2.11 | 2.33 | < 0.02 | < 0.02 | 94.50 |
7 | 2497.2 | 187.44 | 34.722 | 32.79 | 1.94 | 2.30 | < 0.02 | < 0.02 | 98.30 |
6 | 2749.3 | 191.33 | 34.728 | 32.70 | 1.79 | 2.29 | < 0.02 | < 0.02 | 102.42 |
5 | 2997.8 | 194.54 | 34.728 | 32.75 | 1.63 | 2.30 | < 0.02 | < 0.02 | 106.95 |
4 | 3501.4 | 200.71 | 34.721 | 33.01 | 1.29 | 2.32 | < 0.02 | < 0.02 | 115.87 |
3 | 4000.6 | 202.54 | 34.716 | 33.33 | 1.16 | 2.34 | < 0.02 | < 0.02 | 120.11 |
2 | 4500.9 | 204.50 | 34.713 | 33.30 | 1.14 | 2.34 | < 0.02 | < 0.02 | 122.06 |
1 | 4745 | 207.63 | 34.712 | 33.13 | 1.11 | 2.33 | < 0.02 | < 0.02 | 122.98 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |