Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-16 20:35 to 2018-09-17 01:21 UTC
Where: 34° 24.0' S 152° 26.7' E
Maximum Depth (m): 4790.4
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
32 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.6 | < 0.02 | < 0.02 | 1.06 | 19.18 | 0.19 | < 0.02 | 0.26 | 0.74 |
30 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 14.7 | < 0.02 | < 0.02 | 1.06 | 19.17 | 0.18 | < 0.02 | 0.26 | 0.73 |
27 | 30.6 | 232.73 | 35.752 | 1.05 | 19.18 | 0.18 | < 0.02 | 0.26 | 0.74 |
26 | 40.3 | < 0.02 | < 0.02 | 1.05 | 19.17 | 0.18 | < 0.02 | 0.26 | 0.71 |
25 | 50.1 | < 0.02 | < 0.02 | 1.03 | 19.15 | 0.17 | < 0.02 | 0.24 | 0.75 |
24 | 60.6 | < 0.02 | < 0.02 | 1.02 | 19.08 | 0.17 | 0.02 | 0.21 | 0.76 |
23 | 68.2 | < 0.02 | < 0.02 | 1.04 | 18.96 | 0.17 | 0.03 | 0.19 | 0.76 |
22 | 100.5 | < 0.02 | < 0.02 | 18.60 | 18.28 | 1.30 | < 0.02 | 0.07 | 44.99 |
21 | 125.9 | 219.96 | 35.658 | 3.44 | 17.87 | 0.33 | < 0.02 | 0.18 | 1.20 |
20 | 150.8 | < 0.02 | < 0.02 | 2.08 | 17.84 | 0.25 | < 0.02 | 0.52 | 0.84 |
19 | 199.9 | < 0.02 | < 0.02 | 3.93 | 17.63 | 0.37 | < 0.02 | 0.07 | 1.36 |
18 | 299.1 | < 0.02 | < 0.02 | 7.02 | 15.76 | 0.57 | < 0.02 | 0.02 | 2.33 |
17 | 500.2 | < 0.02 | < 0.02 | 15.24 | 11.62 | 1.07 | < 0.02 | < 0.02 | 5.55 |
16 | 750.7 | 205.13 | 34.592 | 22.73 | 8.36 | 1.56 | < 0.02 | < 0.02 | 11.66 |
15 | 1001.2 | 197.76 | 34.451 | 28.22 | 6.19 | 1.95 | < 0.02 | < 0.02 | 26.21 |
14 | 1104.2 | 191.15 | 34.445 | 30.08 | 5.49 | 2.08 | < 0.02 | < 0.02 | 35.47 |
13 | 1250.1 | 177.80 | 34.476 | 32.51 | 4.50 | 2.27 | < 0.02 | < 0.02 | 54.59 |
12 | 1502.3 | 159.71 | 34.552 | 35.10 | 3.35 | 2.48 | < 0.02 | < 0.02 | 82.65 |
11 | 1753.3 | 159.17 | 34.611 | 35.40 | 2.75 | 2.51 | < 0.02 | < 0.02 | 94.00 |
10 | 2003.1 | 168.06 | 34.658 | 34.62 | 2.39 | 2.45 | < 0.02 | < 0.02 | 95.53 |
9 | 2251.1 | 177.13 | 34.690 | 33.83 | 2.17 | 2.38 | < 0.02 | < 0.02 | 96.02 |
8 | 2501.9 | 183.24 | 34.710 | 33.33 | 2.01 | 2.35 | < 0.02 | < 0.02 | 98.07 |
7 | 2755.4 | 189.59 | 34.723 | 32.95 | 1.81 | 2.31 | < 0.02 | < 0.02 | 102.06 |
6 | 3002.5 | 193.34 | 34.724 | 32.97 | 1.61 | 2.32 | < 0.02 | < 0.02 | 107.00 |
5 | 3504.6 | 199.14 | 34.720 | 33.19 | 1.30 | 2.34 | < 0.02 | < 0.02 | 115.31 |
4 | 4007.3 | 201.20 | 34.717 | 33.38 | 1.20 | 2.35 | < 0.02 | < 0.02 | 119.05 |
2 | 4507.5 | 201.29 | 34.716 | 33.46 | 1.20 | 2.35 | < 0.02 | < 0.02 | 120.47 |
3 | 4508.4 | 201.42 | 34.716 | 33.48 | 1.20 | 2.36 | < 0.02 | < 0.02 | 120.64 |
1 | 4790.4 | 201.91 | 34.716 | 33.45 | 1.22 | 2.35 | < 0.02 | < 0.02 | 120.96 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |