Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-16 16:16 to 2018-09-16 18:05 UTC
Where: 34° 24.2' S 152° 29.0' E
Maximum Depth (m): 1501.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 6.1 | 231.43 | 35.746 | 1.19 | 19.09 | 0.18 | 0.08 | 0.23 | 0.58 |
36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 19.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.4 | < 0.02 | < 0.02 | < 0.02 | 19.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15.9 | < 0.02 | < 0.02 | 1.19 | 19.10 | 0.18 | 0.08 | 0.23 | 0.60 |
32 | 20.6 | < 0.02 | < 0.02 | < 0.02 | 19.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 21 | < 0.02 | < 0.02 | 1.20 | 19.10 | 0.18 | 0.08 | 0.23 | 0.55 |
29 | 30.8 | < 0.02 | < 0.02 | 1.21 | 19.11 | 0.18 | 0.08 | 0.23 | 0.56 |
30 | 31.4 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 38.9 | < 0.02 | < 0.02 | 1.21 | 19.11 | 0.18 | 0.08 | 0.23 | 0.62 |
28 | 39.5 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 50.7 | < 0.02 | < 0.02 | 1.21 | 19.11 | 0.18 | 0.08 | 0.23 | 0.57 |
24 | 60.6 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 60.7 | < 0.02 | < 0.02 | 1.20 | 19.11 | 0.18 | 0.08 | 0.23 | 0.60 |
21 | 70.9 | < 0.02 | < 0.02 | 1.20 | 19.11 | 0.18 | 0.09 | 0.23 | 0.62 |
22 | 71.1 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 19.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 100.1 | 230.81 | 35.744 | 1.26 | 19.11 | 0.18 | 0.07 | 0.23 | 0.61 |
17 | 126.2 | < 0.02 | < 0.02 | 2.02 | 18.75 | 0.23 | < 0.02 | 0.34 | 0.69 |
18 | 126.4 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 152.2 | < 0.02 | < 0.02 | 2.50 | 18.66 | 0.26 | < 0.02 | 0.11 | 0.75 |
15 | 202.6 | < 0.02 | < 0.02 | 2.54 | 18.39 | 0.26 | < 0.02 | 0.22 | 0.81 |
14 | 299.2 | 202.63 | 35.490 | 7.12 | 16.25 | 0.56 | < 0.02 | < 0.02 | 2.16 |
13 | 399.9 | 207.67 | 35.300 | 10.24 | 14.41 | 0.76 | < 0.02 | < 0.02 | 3.21 |
12 | 500.3 | 212.18 | 35.052 | 13.99 | 12.11 | 0.99 | < 0.02 | < 0.02 | 4.78 |
11 | 600.1 | 203.88 | 34.789 | 18.52 | 10.14 | 1.28 | < 0.02 | < 0.02 | 7.48 |
10 | 699.7 | < 0.02 | < 0.02 | 21.09 | 9.00 | 1.46 | < 0.02 | < 0.02 | 9.44 |
9 | 799.9 | 204.46 | 34.546 | 23.88 | 7.89 | 1.64 | < 0.02 | < 0.02 | 13.64 |
8 | 901.5 | 202.09 | 34.479 | 26.30 | 6.90 | 1.81 | < 0.02 | < 0.02 | 19.47 |
7 | 1001.6 | < 0.02 | < 0.02 | 28.29 | 6.14 | 1.96 | < 0.02 | < 0.02 | 27.01 |
6 | 1101.9 | 196.73 | 34.449 | 30.22 | 5.38 | 2.10 | < 0.02 | < 0.02 | 37.22 |
5 | 1200.8 | < 0.02 | < 0.02 | 31.79 | 4.74 | 2.23 | < 0.02 | < 0.02 | 48.53 |
4 | 1300.9 | 174.00 | < 0.02 | 33.09 | 4.22 | 2.32 | < 0.02 | < 0.02 | 60.90 |
3 | 1401.2 | < 0.02 | < 0.02 | 34.15 | 3.74 | 2.42 | < 0.02 | < 0.02 | 72.63 |
2 | 1501.7 | < 0.02 | < 0.02 | < 0.02 | 3.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1501.7 | 163.59 | 34.545 | 34.78 | 3.40 | 2.46 | < 0.02 | < 0.02 | 80.84 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |